GarrettCom DS80C Connecting Fiber Optic ST-type, twist-lock, Connecting Single-Mode Fiber Optic

Page 19

Magnum DS80F & DS80C Dual-speed Stackable Hubs

Installation and User Guide (12/01)

3.2.2Connecting Fiber Optic ST-type, “twist-lock”

The following procedure applies to installations using ST-type fiber connectors. This procedure applies to ports using a multi-mode ST fiber connectors.

1.Before connecting the fiber optic cable, remove the protective dust caps from the tips of the fiber connectors. Save these dust caps for future use.

2.Wipe clean the ends of the dual connectors with a soft cloth or lint-free lens tissue dampened in alcohol. Make certain the connectors are clean before connecting.

Note: One strand of the duplex fiber optic cable is coded using color bands at regular intervals; you must use the color-coded strand on the associated ports at each end of the fiber optic segment.

3.Connect the Transmit (TX) port (light colored post) on the Magnum Fiber port to the Receive (RX) port of the remote device. Begin with the color-coded strand of the cable for this first TX-to-RX connection.

4.Connect the Receive (RX) port (dark colored post) to the Transmit (TX) port of the remote device. Use the non-color coded fiber strand for this.

5.The LINK LED on the front of the fiber connector will illuminate when a proper connection has been established at both ends (and when power is ON in the unit). If LINK is not lit after cable connection, the normal cause is improper cable polarity. Swap the fiber cables at the fiber connector to remedy this situation.

3.2.3 Connecting Fiber Optic SC-type, "Snap-In"

The following procedure applies to installations using SC-type fiber connectors, i.e., using multi-mode SC and SC single-mode.

When connecting fiber media to SC connectors, simply snap on the two square male connectors into the SC female jacks of the Fiber connector until it clicks and secures.

3.2.4Connecting Single-Mode Fiber Optic

When using single-mode fiber cable, be sure to use single-mode fiber port connectors. Single-mode fiber cable has a smaller diameter than multi-mode fiber cable (9/125 microns for single-mode, 50/125 or 62.5/125 microns for multi-mode where xx/xx are the diameters of the core and the core plus the cladding respectively). Single-mode fiber allows full bandwidth at longer distances, about 20Km with the multi-mode SC.

The same procedures as for multi-mode fiber apply to single-mode fiber connectors. Follow the steps listed in Section 3.2.2 above.

3.2.5Power Budget Calculations for DS80F Fiber Media

Receiver Sensitivity and Transmitter Power are the parameters necessary to compute the power budget. To calculate the power budget of different fiber media installations using Magnum products, the following equations should be used:

OPB (Optical Power Budget) = PT(min) - PR(min)

where PT = Transmitter Output Power, and PR = Receiver Sensitivity

Worst case OPB = OPB - 1dB(for LED aging) - 1dB(for insertion loss)

www . GarrettCom . com

14

Image 19
Contents Magnum DS80F & DS80C Personal Hubs Trademarks Email support@garrettcom.com Contacting GarrettCom, IncMagnum Line Specifications Network Standards Technical Specifications Performance of Dual-Speed PortsPower Supply External External -48VDC Power Supply OptionalUp-Link, Port # 1 SW Manual Switch DS80C FF or a switchDS80F F or H switch LED IndicatorsOrdering Information Inspecting the Package and Product Introduction10Mbps Hub 100Mbps Hub Product Description GeneralMagnum DS80C chassis with all RJ-45 Copper ports Fiber ST above, fiber SC at rightUp-link Port 1SW for Cascading 3 10 / 100 Speed Auto-sensingFiber port for DS80F Series Www . GarrettCom . com Small enclosure enables use in offices, labs and classrooms Internal switches connects all of the ports and users100Mbps fiber Applications Magnum DS80C Dual Speed Personal Hub Example 2. Magnum DS80CTable-Top or Shelf Mounting Locating Magnum DS80F & DS80C Dual-Speed HubsWall or vertical surface mounting Media Ieee Standard Connecting Ethernet MediaPower Budget Calculations for DS80F Fiber Media Connecting Fiber Optic ST-type, twist-lockConnecting Fiber Optic SC-type, Snap-In Connecting Single-Mode Fiber OpticTypical Powering the Magnum DS80F and DS80CWww . GarrettCom . com Switching, Filtering and Forwarding Dual-speed functionality, and switchingSwitching, Address Learning Auto-negotiation and speed-sensing Up-link Port LED’sUse with Media Converters Before Calling for Assistance TroubleshootingReturn Material Authorization RMA Procedure When Calling for AssistanceShipping and Packaging Information No Problem Found