Magnum | Installation and User Guide (08/98) |
|
|
1.0SPECIFICATIONS
1.1Technical Specifications
119,040 frames per second, 8 ports
297,600 frames per second, 2 TX ports (for Magnum 528 Fast Ethernet ports)
Aggregate Forwarding Rate: 59,520 frames per second, 4
|
| 148,800 frames per second, 2 |
|
| (for Magnum 528 Fast Ethernet ports) |
Data Rate: |
| 10 Mbps and 100 Mbps |
Address Table Capacity: | 2K (1954) node addresses | |
Buffer Size : |
| 1 MB |
Latency: | 5 ∝ s + packet time | |
| 15 ∝ s + packet time | |
| and |
Network Standards
Ethernet V1.0/V2.0 IEEE 802.3:
IEEE 802.3u:
Maximum Ethernet Segment Lengths |
|
| ||
Unshielded twisted pair |
| - | 100 m (328 ft) |
|
Shielded twisted pair |
| - | 150 m (492 ft) |
|
Maximum Standard Fast Ethernet Segment Lengths: |
| |||
|
| 100 m (328 ft) | ||
412 m (1350 ft) | ||||
2.0 km (6,562 ft) | ||||
412 m (1350 ft) | ||||
15 km (49,215 ft) | ||||
Connectors for copper wiring |
|
|
|
|
8 Twisted Pair @ 10Mb | : | |||
2 Twisted Pair @ 100Mb) | : | |||
(for Magnum 528 Fast Ethernet copper ports, normally use Cat 5 cable) | ||||
Fiber |
|
|
| |
Fiber Port, | Fiber optic | |||
Fiber Port, | ||||
Fiber |
|
|
| |
Fiber Port, SC- and | Fiber optic |
Manual Switches
Full / Half duplex manual switch: Two switches, one for each 100Mb port (for Magnum 528 and 528F Fast Ethernet ports only)
GARRETT
1