Note: The GND should be hooked up first. The 6K16-Series unit has a floating ground, so the user may elect to Ground either + or = terminal to suit the customer’s use.

Before connecting hot lines to the Terminal Block of –48VDC, 24VDC or 125VDC, always use a digital voltmeter to measure the output voltage of the power supply and determine the lead which is more “+ve potential”. The more “+ve” voltage lead from 48V or –48V supply must be connected to the post labeled “+”.

An ON-OFF manual switch is optional for DC power. This can be used to cut off power connections and as a RESET for the Magnum 6K16-Series Switch.

B4.1 UL Requirements for DC-powered units

1.Minimum 18AWG cable for connection to a Centralized DC power source.

2.Minimum 14AWG cable for connection to a earthing wiring.

3.Use only with Listed 10 A circuit breaker provided in building installation.

4.“Complies with FDA radiation performance standards, 21 CFR subchapter J.” or equivalent.

5.Fastening torque of the lugs on the terminal block: 9 inch-pound max.

6.Centralized DC Power Source cable securement, use at least four cable ties to secure the cable to the rac,k at least 4 inches apart, with the first one located within 6 inches of the terminal block.

B5.0 OPERATION

Operation of Magnum 6K16-Series Switches with the optional -48VDC, 24VDC and 125VDC power supply is identical to that of the standard AC-powered models.

B6.0 ORDERING INFORMATION

To order the optional -48VDC power supply factory installed, add a suffix of “- -48VDC” after the product’s standard model # Example: Magnum 6K16-SeriesR-

48VDC.

Similarly to order the optional 24VDC or 125VDC industrial specific power supply factory installed, add a suffix of “ 24VDC” or “125VDC” after the product ‘s standard model #. Example: Magnum 6K16-Series- 24VDC, Magnum 6K16-Series- 125VDC.

B7.0 TROUBLESHOOTING

Please refer to Section 6.0 for troubleshooting

APPENDIX C: Internal DC Dual-Source Power Option

C1.0 SPECIFICATIONS - FOR MAGNUM 6K16-SERIES FIBER SWITCH

www . GarrettCom . com

62

Image 70
Contents Managed Fiber Switch Trademarks Contacting GarrettCom, Inc Canadian EmissionInstallation Table of ContentsIntroduction Intro Magnum 6K16/6K16V Managed Fiber Switch Port Modules45 OperationWww . GarrettCom . com Overview Bridge Port Modules BPMS, 4 TYPES, for Segment Media CONVERTERS, 10MB and 100MB SeriesTRANSCEIVERS, 10MB Series MINI-TRANSCEIVERS and Coax Models Network Standards and Compliance, hardware Technical SpecificationsPerformance Maximum 10 Mbps Ethernet Segment LengthsManagement Console connector Fiber Single-mode connector typesAlarm Relay Contacts Power Supply InternalAgency Approvals and Standard Compliance Magnum 6K16V Per-port MDI or Mdix on RJ-45Mountings Magnum 6K16Ordering Information 6KP8-SLC 6KP8-MTRJ6KP8-MLC 6KP4-FXSCWww . GarrettCom . com 6K PoE Modules with 48VDC Pass-Through Introduction Inspecting the Package and Product Product Description Magnum 6K16-Series 6K16/6K16V 1a Magnum 6K16V, Managed Fiber Switch 1b Magnum 6K16, Managed Carrier Class Switch 1c Magnum 6K16-Series family 6K16 and 6K16V, At a glance Set-up of the software See Magnum 6K-MNS Software Manual for Flexibility to adapt to any FDX orEight-Port Copper Module, 6K8-RJ45 Per the IEEE802.3af PoE Port modules are also available with Four-Port 10 Mb and 100Mb mm Fiber ST ModulesMagnum Combo six @ Mtrj 100Mb mm SFF fiberGigabit 1000Mbps port modules Packet Prioritization, 802.1p QOSFrame Buffering and Flow Control Managed Network Software MNS-6K for Magnum 6K8-Series GarrettCom proprietary MIBs for Snmp„ Managed switching for high performance Ethernet LANs Features and Benefits„ Features Fiber-Built-In Applications Magnum 6K25 Snmp Backup Locating Magnum 6K16-Series Switches Connecting Ethernet MediaConnecting Single-Mode Fiber Optic Connecting Fiber Optic ST-type, twist-lockConnecting Fiber Optic SC-type, Snap-In Ieee Standard Media Type Max. Distance Port Module FiberMedia Ieee Standard Connecting Gigabit Media Using GBICs DIN-Rail Mounting Magnum 6K16VWww . GarrettCom . com Mounting Dimensions for 6K16Vwith metal brackets 2a- One Magnum 6K16 deployed over a K16-2Tray Powering the Magnum 6K16-Series Managed Fiber Switch Relay Contacts6K16-Series Port Module 6KPM Installation Preparation for Installing and Removing 6KPMsRemove Chassis Cover 1a Removing the Front panel from the unitInstalling 6KPM Cards in the Magnum 6K16-Series Remove front panel face plate retaining screwsUplink Switch 2f Securely latching up 6KPM Cards into a Magnum 6K16-Series Removing 6KPM Cards 3b Removing a 6KPM Card1 RS-232 DB-9 Console Com port Serial port pin assignments DB-9 Console port connectorEnlarged view of Magnum 6K16-Series Console Port area Filtering and Forwarding Switching FunctionalityAddress Learning Auto-CrossMDIX and Auto-negotiation, for RJ-45 ports Up-link Manual Switches set as = , for RJ-45 port onlyStatus LEDs PWRWww . GarrettCom . com Flow-control, Ieee 802.3x standard 6KP4V ’cvr6KPM Module Description Dual speed copper ports. Segments. When installed in aSwitch, the copper port Magnum 6K16-Series Managed1b 6KP4-F10ST, 4@10Mb multi-mode FX-ST twist lock Module Transceivers all in one module. This Mode 100Mbps fiber opticMagnum 6KP6 Activity ACT, Link LK,Www . GarrettCom . com Activity FULL/HALF Port@ 100Mbps Multi-Mode Fiber portLink Module is a combo module with Mtrj type ports. The small size Mtrj connectors provides anMagnum 6KP8-45MT Copper and fiber Small Form Factor9 6KP8-RJ45 Twisted Pair, 10/100Mb 8-Port Fig. the top 8-RJ45 PoE LEDs SummaryMagnum 6KP8 GBIC-SXSC Gigabit fiber1000Mb, multi-mode SC Connector 13a GBIC-LXSC Gigabit fiber 1000Mb, multi-mode SC Connector14 6KM-BLNK @ 1000Mb Fiber SC + 2@ 100Mb SCBefore Calling for Assistance When Calling for Assistance Return Material Authorization RMA ProcedureNo Problem Found Appendix B Internal DC Power Supply OptionsShipping and Packaging Information B2.0 -48VDC, 24VDC and 125VDC POWER, Theory of Operation B3.0 Applications for DC Powered Ethernet Switches B4.0 6K16-SERIES, -48V, 24, 125 or 5VDC InstallationB5.0 Operation B7.0 TroubleshootingC1.0 Specifications for Magnum 6K16-SERIES Fiber Switch B6.0 Ordering InformationC4.0 Features and Benefits of the DUAL-SOURCE Design GNDC5.0 Installation Example Magnum 6K16-SeriesR-48VDC C5.1 UL RequirementsC6.0 Ordering Information C7.0 Operation

84-00136 specifications

GarrettCom 84-00136 is a robust and reliable networking solution widely recognized for its versatility and performance in demanding environments. Specifically designed for industrial applications, the device excels in offering connectivity within harsh conditions, ensuring seamless communication across various network topologies.

One of the standout features of the GarrettCom 84-00136 is its high port density. With multiple Ethernet ports, it allows for extensive network connections, making it an ideal choice for facilities that require numerous devices to be interlinked. This capability ensures that organizations can efficiently manage their communication needs without compromising on performance.

Another significant characteristic of the 84-00136 is its industrial-grade durability. Built to withstand extreme temperatures, vibrations, and shocks, the device is suited for applications in manufacturing plants, transportation systems, and utility networks. This level of resilience is essential for maintaining reliable operations in environments where standard networking equipment might fail.

The technology behind the GarrettCom 84-00136 includes advanced switching capabilities. With support for both managed and unmanaged configurations, users can choose the level of control and customization that best fits their network requirements. The managed features allow for extensive monitoring and management, facilitating better network performance and security.

In addition, the 84-00136 supports various communication protocols, improving interoperability with existing systems. This flexibility is crucial for organizations looking to integrate new technologies into their established networks without overhauling the entire system.

Security is another critical aspect of the GarrettCom 84-00136. The device is equipped with robust security features, ensuring that network data remains protected from unauthorized access. This is particularly important in industrial environments where sensitive information must be safeguarded against potential cyber threats.

Ease of installation and maintenance is also a highlight of the GarrettCom 84-00136. Its user-friendly design allows for straightforward setup, minimizing downtime during deployment. Furthermore, ongoing maintenance is simplified through an intuitive interface, enabling quick troubleshooting and adjustments.

In summary, the GarrettCom 84-00136 is a high-performance networking solution tailored for industrial applications. Its impressive features, including high port density, industrial-grade durability, advanced switching capabilities, and robust security measures, make it an optimal choice for organizations seeking reliable and efficient network connectivity in challenging environments.