GE PBe manual Installation environment, Power specifications

Page 9

5

Installation environment

Power. Ensure that the installation site’s AC power is stable and within the rated voltage of the external power supply. If the site’s AC power is likely to have spikes or DIPs, use power line conditioning or an uninterruptible power supply.

Temperature. Observe the unit’s ambient temperature specifications when choosing a location for the unit. Extremes of heat or cold beyond the specified operating temperature limits may cause the unit to fail. Do not install this unit on top of other hot equipment.

Moisture. Do not expose the unit to rain or moisture. Moisture can damage internal components. Do not install this unit near sources of water.

RS-232 limitations. Cable length between the POS device and the PBe is limited to 50 ft. (15.24 m) Cable length between the PBe unit and the DVR is also limited to 50 ft. (15.24 m). If the supplied cables are replaced by custom made cables to address distances between components, ensure the cable is manufactured to ANSI standards for RS-232 communication.

Power specifications

The PBe is furnished with a power supply (110 or 240 VAC). Do not use any other power supply with this product. The manufacturer accepts no responsibility for damage caused by the use of any other power supply.

Make sure installation is complete and all connections are made before applying power to the unit.

Image 9
Contents ProBridge Ethernet Regulatory Contents Page Introduction Conventions used in this document Safety terms and symbolsOverview CompatibilityDisclaimer Other required equipment Product contentsPower specifications Installation environment4310-0008 220VAC power supply 4310-0007 120 VAC power supplyPBe components InstallationMultiple ATM system layout Typical system layoutInstallation overview Required informationEthernet device type Installation steps Required DIP switch informationImportant switch assignments Default switch settingsPage Programming HyperTerminal configurationLaptop connected to PBe Press the Enter key twice to bring up the Main Menu PBe Set-up menu Main MenuTerminal IP/camera set-up menu Terminal IP/Camera Set-up menuCamera/terminal IP table Monitor Mode menuManual DIP switch configuration Analyzer Mode menuExiting HyperTerminal Page SW1 switches 1 to DIP switch settingsSW1 switches 5 to SW4 switches 7 SW3 switches 1 toAccessing the Webserver PBe home Problem Probable cause Solution TroubleshootingPBe Technical specificationsGeneral EnvironmentalPBe to DVR Cable Specifications0061 cable PBe to PC0040 PBe Ethernet PBe Ethernet cableOnline publication library Contacting technical support