GE Power Supply user manual Installation, Package contents, Location, Rear panel

Page 7

g

Digital EnergyGT Series

2 - Installation

2.1Package contents

The packing box contains a Digital Energy™ GT Series-UL UPS, an RS232 data cable, a CD ROM, two mounting brackets with screws and this manual. Carefully inspect the packing box and its contents. If any damage is visible please immediately notify the carrier and/or dealer.

2.2Location

Please refer to section 1.3 of ‘IMPORTANT SAFETY INSTRUCTIONS’

2.3Rear panel

1

Input

 

AC utility supply power to the UPS

2

Input breaker

 

Protects the UPS from damage

 

caused by high input currents

3

Output receptacles

 

To connect the critical load to the

 

UPS

4

Output circuit breaker

 

Protects the UPS from damage

 

caused by output overload

5

DC connector

 

To connect external battery pack

 

for extended runtime

6

Fan

 

Electronically controlled cooling

 

fan. Make sure ventilation air can

 

move freely around and trough the

 

UPS.

9 5 6

7

9 8 6

7

9 8 6

8 2 3

11000VA

2

1

3

5

1500VA

2

1

3

5

7

Communication interface

RS232/dry

contact.

Allows

communication between computer and UPS. See chapter 4 for more detailed information.

8TVSS - Transient Voltage Surge Suppressor (RJ-45/RJ-11): To prevent damage caused by surges, noise and spikes traveling over the telephone or network line. (Optional)

9SNMP Slot

An (optional) SNMP adapter can be plugged into this port for managing the UPS via the network. See chapter 4 for more detailed information.

 

7

 

 

 

4

2200VA

8

7

6

2

8

3

 

9

1

5

4

3000VA

 

Fig 2.1

Rear panels

 

 

OPM_GTU_19X_1K0_3K0_XUS_V014

6

GT-UL Series: User manual 1.2 (US)

Image 7
Contents Digital EnergyTMGT Series Digital Energy GT Series Important Safety Instructions Installation Important Safety InstructionsGeneral Transport/storage Batteries1kVA Model Fccis Interference StatementsRear panel InstallationPackage contents LocationMounting in a 19 enclosure Vertical installationConnecting the load Connecting an external battery packUL 1778 safety requirement Connecting the RS232/dry contact interfaceChecking the site-wiring fault LED Connecting to the utility power supply 1000/1500VA2200/3000VA Operation Panel OperationUse Normal Operation Start-upUse Abnormal Conditions Bypass operation Replace batteryShort circuit Description CommunicationDry Contact RS232Snmp Plug-in Card optional SpecificationsFunctions Maintenance Optional FeaturesBattery replacement procedure 1.5kVA 1 Remove front panel Recycling the UPS at the end of service lifeBattery replacement procedure 3kVA Problem Possible Cause Solution TroubleshootingGT Model 1000R UL 1500R UL 2200R UL 3000R UL Specifications