GE CS300 manual Converter Size Selection, Converter DC link current Terminals C / D

Page 14

GEH-6639

2.6 CONVERTER SIZE SELECTION

Within the specified voltage field, the CS300 converter supplies the same rated direct current independently of the voltage itself. The increase of the output voltage causes an increasing in the transferred power, whereas inverters are devices with a typically constant transferred power (the supplied current decreases with the increasing of the output voltage).

As for the choice, therefore, the calculation is based on a common unit, the direct current of the intermediate circuit, which, as for the inverters, is not mentioned into the product instruction manual and has therefore to be calculated. Furthermore, the confrontation between the two foreseen functioning classes has to be homogeneous (IEC 146 class 1 and 2).

2.6.1 Output Rated Currents for the Two Functioning Classes

Converter

DC link current (Terminals C / D)

IEC 146 Class 1 *

IEC 146 Class 2 **

 

 

 

 

6KCS3185-480

185 A

150 A

6KCS3280-480

280 A

225 A

6KCS3420-480

420 A

340 A

6KCS3650-480

650 A

540 A

6KCS310H-480

1050 A

850 A

6KCS315H-480

1500 A

1300 A

cs060

* Continuous service

** Service with overload possibility of 150% for 60 seconds

14——————— INSTRUCTION MANUAL ————————

Image 14
Contents CS300 Page Safety Symbol Legend / Légende DES Signes DE Sécurité GEH-6639 Table of Contents GEH-6639 Safety Precautions GEH-6639 CS300 GEH-6639 General Description Power SupplyDescription of Power Terminals FunctionConverter Description of Control TerminalsTerminals Function Voltage, Current VaristorsExternal AC Mains Fuses MainConverter Size Selection Converter DC link current Terminals C / DRated motor Motor Current Fuses AV300 -… Dclink I DCL DClink I DCLSelection of the CS300 Converter DIP-SWITCHES and JumperUSE of S1 Switch = 1331.21 rad/S USE of S2 Switch USE of S3 SwitchAC Mains frequency USE of S4 and S5 DIP SwitchUSE of CV Jumper Control Description MLP SignalML Signal OK RelayConverter Dimensions Converter Form WeightConverter Operation Example of Terminal Strip ConnectionSignal Diagram Figure aCommon BUS MULTI-INVERTER System Replacement Parts Regulation cardWarranty Parts and Service GE Industrial SystemsCS300 Half controlled power supply for inverter DC-Link GE Industrial Systems