GE CS300 manual General Description, Power Supply, Description of Power Terminals, Function

Page 11

CS300

Chapter 2 - COMPONENT IDENTIFICATION AND SPECIFICATION

2.1 GENERAL DESCRIPTION

CS300 is a half-controlled three phase AC/DC converter for supplying DC link voltage to a series of AC Drives, with C and D terminals parallel connected.

The precharge of the drive capacitors (time setting set via dip-switches) is done by partializing the mains voltage via a thyristors bridge. A diagnostic circuit allows detection of a mains power supply dip for system use.

NOTE! The direct parallel connection of the outputs (U2,V2,W2 terminals) of two or more inverters is not possible !

2.2 POWER SUPPLY

CS300 converter can be connected to the three phase power supply having the following characteristics:

400V-15%

up to

480+10%

50 or 60 Hz

 

(Dip-switch selectable)

The maximum input power of the internal switching power supply is 100W, and the supplied voltages are:

+/-15V 500mA

Control card

+24 V 2A

Fan power supply (if present) and auxiliary functions (regulator

 

terminals power supply)

2.3 DESCRIPTION OF POWER TERMINALS

Terminals

Function

U, V, W

Power supply via AC mains, 3Ph (400V –15% up to 480V +10%)

CPositive terminal to be connected to the inverter DC-LINK

DNegative terminal to be connected to the inverter DC-LINK

U3, V3

Supply for internal fan (only for 1050A size and higher)

(1Ph, 230V ± 15%)

 

cs010

——————— Half controlled power supply for inverter DC-Link ————————

11

Image 11
Contents CS300 Page Safety Symbol Legend / Légende DES Signes DE Sécurité GEH-6639 Table of Contents GEH-6639 Safety Precautions GEH-6639 CS300 GEH-6639 Function Power SupplyDescription of Power Terminals General DescriptionVaristors Description of Control TerminalsTerminals Function Voltage, Current ConverterMain External AC Mains FusesConverter DC link current Terminals C / D Converter Size SelectionDclink I DCL DClink I DCL Rated motor Motor Current Fuses AV300 -…Selection of the CS300 Converter DIP-SWITCHES and JumperUSE of S1 Switch = 1331.21 rad/S USE of S3 Switch USE of S2 SwitchAC Mains frequency USE of S4 and S5 DIP SwitchUSE of CV Jumper OK Relay MLP SignalML Signal Control DescriptionConverter Form Weight Converter DimensionsExample of Terminal Strip Connection Converter OperationFigure a Signal DiagramCommon BUS MULTI-INVERTER System Regulation card Replacement PartsGE Industrial Systems Warranty Parts and ServiceCS300 Half controlled power supply for inverter DC-Link GE Industrial Systems