GE CS300 manual Safety Precautions

Page 7

CS300

Chapter 1 - SAFETY PRECAUTIONS

NOTE!The terms “Inverter”, “Controller” and “Drive” are sometimes used interchangably through- out the industry. We will use the term “Drive” in this document

Les mots “Inverter”, “Controller” et “Drive” sont interchangeables dans le domaine industriel. Nous utiliserons dans ce manuel seulement le mot “Drive”.

WARNING! / ATTENTION!

According to the EEC standards the CS300 and accessories must be used only after checking that the machine has been produced using those safety devices required by the 89/392/EEC set of rules.

Drive systems cause mechanical motion. It is the responsibility of the user to insure that any such motion does not result in an unsafe condition. Factory provided interlocks and operating limits should not be bypassed or modified.

Never open the device or covers while the AC Input power supply is switched on. Minimum time to wait before working on the terminals or internal devices is 5 minutes.

If the front plate has to be removed because the ambient temperature is higher than 40 degrees, the user has to ensure that no occasional contact with live parts will occur.

Always connect the Drive to the protective ground (PE) via the marked connection terminals (PE2) and the housing (PE1). Adjustable Frequency Drives and AC Input filters have ground discharge currents greater than

3.5mA. EN 50178 specifies that with discharge currents greater than 3.5 mA the protective conductor ground connection (PE1) must be fixed type and doubled for redundancy.

The drive may cause accidental motion in the event of a failure, even if it is disabled, unless it has been discon- nected from the AC input feeder.

Selon les normes EEC, les drives CS300 et leurs accessoires doivent être employés seulement après avoir verifié que la machine ait été produit avec les même dispositifs de sécurité demandés par la réglementation 89/392/ EEC concernant le secteur de l’industrie.

Les systèmes provoquent des mouvements mécaniques. L’utilisateur est responsable de la sécurité concernant les mouvements mécaniques. Les dispositifs de sécurité prévues par l’usine et les limitations operationelles ne doivent être dépassés ou modifiés.

Ne jamais ouvrir l’appareil lorsqu’il est suns tension. Le temps minimum d’attente avant de pouvoir travailler sur les bornes ou bien à l’intérieur de l’appareil est 5 minutes.

Si la plaque frontale doit être enlevée pour un fonctionnement avec la température de l’environnement plus haute que 40°C, l’utilisateur doit s’assurer, par des moyens opportuns, qu’aucun contact occasionnel ne puisse arriver avec les parties sous tension.

Effectuer toujours des connexions de terre (PE) par le biais des bornes (PE2) et du chassis (PE1). Le courant de dispersion vers la terre est supérieur à 3,5 mA. Selon EN 50178 il faut prévoir dans ces cas une double connexion à terre.

WARNING! - ELECTRICAL SHOCK AND BURN HAZARD /

ATTENTION! – DÉCHARGE ÉLECTRIQUE ET RISQUE DE BRÚLURE :

When using instruments such as oscilloscopes to work on live equipment, the oscilloscope’s chassis should be grounded and a differential amplifier input should be used.

Care should be used in the selection of probes and leads and in the adjustment of the oscilloscope so that accurate readings may be made. See instrument manufacturer’s instruction book for proper operation and adjustments to the instrument.

Lors de l’utilisation d’instruments (par example oscilloscope) sur des systémes en marche, le chassis de l’oscilloscope doit être relié à la terre et un amplificateur différentiel devrait être utilisé en entrée.

Les sondes et conducteurs doivent être choissis avec soin pour effectuer les meilleures mesures à l’aide d’un oscilloscope. Voir le manuel d’instruction pour une utilisation correcte des instruments.

——————— Half controlled power supply for inverter DC-Link ————————

7

Image 7
Contents CS300 Page Safety Symbol Legend / Légende DES Signes DE Sécurité GEH-6639 Table of Contents GEH-6639 Safety Precautions GEH-6639 CS300 GEH-6639 Function Power SupplyDescription of Power Terminals General DescriptionVaristors Description of Control TerminalsTerminals Function Voltage, Current ConverterMain External AC Mains FusesConverter DC link current Terminals C / D Converter Size SelectionDclink I DCL DClink I DCL Rated motor Motor Current Fuses AV300 -…USE of S1 Switch DIP-SWITCHES and JumperSelection of the CS300 Converter = 1331.21 rad/S USE of S3 Switch USE of S2 SwitchUSE of CV Jumper USE of S4 and S5 DIP SwitchAC Mains frequency OK Relay MLP SignalML Signal Control DescriptionConverter Form Weight Converter DimensionsExample of Terminal Strip Connection Converter OperationFigure a Signal DiagramCommon BUS MULTI-INVERTER System Regulation card Replacement PartsGE Industrial Systems Warranty Parts and ServiceCS300 Half controlled power supply for inverter DC-Link GE Industrial Systems