Falcon SUP700-1C, SUP1.0K-1C manual 700VA & 1kVA

Page 18

SUP Series™ UPS

700VA & 1kVA

Model Number

Nominal VA

SUP700-1C

SUP1.0K-1C

700

1000

Electrical Input

Nominal AC Voltage

120V or 230V

 

120V or 230V

Current-Amps

7 (120V), 3.6 (230V)

 

10 (120V), 5.2 ( 230V)

AC Voltage Window

 

-21% to 25%

Frequency

 

50/60 Hz (Auto – Tracking)

Frequency Range

 

47 – 63Hz

UPS is designed for use on 120V domestic or 230V international utility power with neutral, line and ground connections.

Electrical Output

Watts

 

490

 

650

Nominal AC Voltage

120V

 

120V

Frequency

 

50/60 Hz (Auto -Tracking)

On-Line Voltage Regulation

 

± 8%

On Battery Voltage Regulation

± 8% Typical (prior to low battery warning)

Waveform

 

 

True Sinewave

Surge Protection

 

 

125 Joules MOV

Unit Protection

 

Short Circuit, Overload & Over Temperature

Efficiency AC to AC (Typical)

97% (120Vac Input), 90% (230Vac Input)

Battery

 

 

 

 

DC Voltage

 

24V

 

24V

Type

 

12V, 7AH x 2

 

12V, 9AH x 2

 

 

Lead Acid Maintenance-Free

 

Lead Acid Maintenance-Free

Back Up Time

@ Full Load

5 Minutes

 

4.5 Minutes

 

@ 1/2 Load

12 Minutes

 

11 Minutes

Recharge Time

 

 

5 Hours

to 90%

Battery times are approximate.

 

 

 

Transfer Time

Bypass to Inverter

Inverter to Bypass

Black-out, 3ms / Brown-out, 0ms

0ms

Electrical Connections

Input

 

 

1 - 6’ Cord with 5-15P &

 

1 - 6’ Cord with 5 -15P &

 

 

 

1 – 6’ Cord with Schuko

 

1 – 6’ Cord with Schuko

Output

 

 

(3) 5-15R

 

(3) 5-15R

Environmental

 

 

 

 

 

Operating Temperature

 

0º C - 40º C (32º F to 104º F)

Altitude

 

 

7,000 Feet

 

Humidity

 

 

10% to 95% Non – Condensing

Cooling

 

 

Low Velocity Forced Air Fans

Audible Noise @ 1 meter

< 45dBA

 

Controls and Indicators

 

 

 

Control

 

 

One Main Control Button – UPS On/Off, Self Test, Reset & Silence Alarms

Selection Control

 

 

Two LCD Metering Scroll Function Select Buttons

LCD Display

 

 

AC Input Voltage, AC Output Voltage, Output Frequency, DC Battery Voltage, Internal UPS

 

 

 

Temperature,

 

 

 

 

Timer – Minutes to Shutdown, Hours to Restart, Battery – Remaining Battery Time

LCD Operational Symbols

Overload, Load Level, UPS is Loaded, Normal Mode, Buck Mode, Boost Mode, Timer Enabled,

 

 

 

High Temperature, Fan Off, Alarm Off, UPS Fault, Battery Low, Battery Level

Audible Alarms

 

 

Low Battery, Defective Battery, Low Battery, Overload, Over Temperature, AC Out of Range

Communications

 

 

RS-232 Serial Port and Contact Closure Signal interface

(Bundled UPSilon 2000 Software)

Mechanical

 

 

 

 

 

Dimensions H x W x D

 

 

 

 

Inches

(mm)

7.9 x 7.1 x 14.2

(200 x 180 x 360)

Weight

lb.

(kg)

33.1 (15)

 

33.1 (15)

Agency Listing

 

 

UL1778, CUL,

FCC Class A

Note: The UPS will go to Green Mode whenever the output load is under 30 watts.

©2004 Falcon® Electric, Inc. All rights reserved. Falcon® and the Falcon Electric logo are registered trademarks of Falcon Electric, Inc. All other brand names and trademarks are the property of their respective owners.

The information and specifications stated in this document are subject to change without notice. 01-07-04 MD44034-A

Falcon Electric, Inc. - 5106 Azusa Canyon Rd. - Irwindale, CA 91706 - 800.842.6940 Fax 626.962.7720

www.falconups.com - email:sales@falconups.com

17

Image 18
Contents Falcon ELECTRIC, INC SUP700-1C, SUP1.0K-1CTable of Contents Important Safety Instructions Chapter Falcon SMP Series OverviewInstallation Definition and setup for RS-232 is as follows Controls, Displays & Functions Front PanelLCD Symbol Descriptions LCD Display Page Typical UPS Rear Panel Alarm Period Status Indicated Operation Battery Charging Maintenance & Technical Support Battery ReplacementNecessary Precautions Technical Support SUPPORT@FALCONUPS.COM626.962.7770 Falcon Web Support Warranty 700VA & 1kVA