Eaton Electrical CA03310002E manual Reversing Contactors Sizes 00

Page 20

20

NEMA Contactors & Starters

 

 

 

 

 

 

 

 

 

 

 

 

IT. Electro-Mechanical

 

 

 

 

September 2003

 

Dimensions

 

 

 

 

 

 

 

Reversing Contactors (Sizes 00 – 4)

 

Table 26. Approximate Dimensions in Inches (mm)

NEMA

Overall

 

 

 

Mounting Holes

 

Req. Mtg.

Terminals

 

 

Size

 

 

 

 

 

 

 

Screws

 

 

 

Width

Height

Depth

Depth w/

Width

Height

Mtg. Hole

Control

Line

Load

 

 

 

 

 

 

Auxiliary

 

 

to Top

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

A

B

C

D

F

G

H

K

P

Q

R

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

00, 0

3.8

5.9

2.7

3.8

3.15

5.35

.3

(3) #10

2.0

1.5

.9

 

(96)

(149)

(69)

(96)

(80)

(136)

(7)

M5

(50)

(38)

(22)

1

4.5

5.9

2.6

3.8

3.15

5.35

.3

(3) #10

2.0

1.5

.6

 

(114)

(149)

(67)

(96)

(80)

(136)

(7)

M5

(50)

(38)

(16)

 

 

 

 

 

 

 

 

 

 

 

 

2

6.2

7.4

3.3

4.4

5.51

6.89

.2

(3) #10

2.6

1.9

.9

 

(158)

(188)

(84)

(112)

(140)

(175)

(6)

M5

(67)

(48)

(22)

 

 

 

 

 

 

 

 

 

 

 

 

3, 4

8.5

9.5

3.8

4.9

7.87

9.06

.2

(3) #10

3.1

2.1

.7

 

(216)

(242)

(97)

(125)

(200)

(230)

(6)

M5

(80)

(54)

(17)

Line Terminals

 

 

 

 

 

 

 

D

 

 

H

K

 

 

 

Q

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

(1 L1, 3 L2, 5 L3)

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Dual Auxiliary –

 

Reduce Dim “D”

 

.31 (8) for the

 

Single Auxiliaries

B G

Load Terminals (2 T1, 4 T2, 6 T3)

R

P

C

Control

 

 

F

Terminal Block

 

 

 

 

 

 

 

A

 

 

 

 

Figure 12. Approximate Dimensions — Inches (mm)

For more information visit: www.cutler-hammer.eaton.com

CA03310002E

Image 20
Contents Contents Nema &ContactorsStartersProduct Description Standards and CertificationsPublications ISO 9002 CertificationCatalog Number Selection Open Components SeptemberIT. Electro-Mechanical Catalog Numbering System ExamplesReversing Contactors FeaturesContents Product Selection Non-reversing ContactorsFull Voltage 3-Pole DC-Operated Non-reversing Contactors NemaFull Voltage 3-Pole DC-Operated Reversing Contactors N511BSAX3NReversing Starters Starters Non-reversing and ReversingNon-reversing Starters With 3-Pole Solid-State Overload ProtectionN501BSAA3A N501BSAB3AN501BSAC3A N501BSAD3AOverall Dimensions in Inches mm w x h x d Weights in Lb. kgMounting Hole Spacing in Inches mm w x h Mounting PositionsDC Power Supply Requirements @ 68F 20C see Note at left Category Typical Application Trip TimesUtilization Categories N04NCS1X3N + N05NCXRL3A = N101CS1L3A Modular Components Contactor Field AssemblyModular Components Starter Field Assembly Nema Contact Block Nema Solid-State Overload Relay Non-reversingNema Coil Controller Nema Contact Block Nema Solid-State Overload Relay Non-reversingAuxiliary Contacts Tables 18 Nema Snap ConnectivityS751 Snap Connectivity Nema N101, N501 Size Continuous Ampacity RatingDeviceNet Specifications Dsnap SpecificationsProduct Selection Transportation/StorageNon-reversing Contactors Sizes 00 Auxiliary Added w Hole to To Top DIN RailNon-reversing Contactors Size Approximate Dimensions in Inches mmNon-reversing Contactors Sizes 2 Reversing Contactors Sizes 00 Reversing Contactors Size Non-reversing Starters Sizes 00 Non-reversing Starter Size Reversing Starters Sizes 00Overall Auxiliary Hole to TopReversing Starter Size