Dew point (Dp) or Frost point (Fp): depending on the selection made here, HW4 will display either the symbol Dp or the symbol Fp. The symbol Fp indicates that any value below freezing is a frost point as opposed to a dew point. When selected, the symbol Fp is also be displayed for values above freezing. This of course is to be understood as being the same as dew point.

Fixed pressure value: Calculating some of the psychrometric parameters requires barometric pressure as an input. Enter here the fixed pressure value that will be used by the HygroClip DI. Note that this numerical value should be consistent with the pressure unit that was selected under Language / Unit System.

Alarm: alarm conditions can be defined for humidity, temperature and the calculated parameter. Values that are below the low alarm value or above the high alarm value will trigger an alarm. A value can be specified for the alarm function hysteresis. This value is used for both the low and the high alarm. To trigger an alarm only in the event that a probe is missing, disconnected or not transmitting data, simply enable the alarm for one of the parameters and set the Hi and Lo values to the range of the probe (for example 0 and 100 for humidity). All versions of HW4 will show an out-of-limits value alarm in red on the monitor screen. HW4 Professional can also be configured (HW4 global settings - Alarm settings tab) to display an alarm table and generate a report whenever an out-of-limits condition occurs.

Digital Interface

This form is used to select the RS-485 baud rate between 57600 and 19200. Other data cannot be changed from within the form. Select the Baud rate depending on which devices you plan to connect with the HygroClip DI. Devices such as the HygroFlex transmitter normally use 19200 bps.

© 2007; Rotronic AG

IN-E-HyClip DI-V1_10.doc

Image 13
Contents IN-E-HyClip DI-V110 HygroClip DI Digital InterfaceHygroClip DI digital interface instruction Manual Contents Models OverviewHygroClip DI-3 Probes Power supplyHygroClip DI-4 HygroClip DI-4-WLIN-E-HyClip DI-V110 Connector identification Operation with the HW4 software Pin-out diagramsHW4 Device Manager File Device Manager Menu BarDevice Information Language / Unit System Probe Inputs Digital Interface Compliance with FDA 21CFR Part II and Gamp IN-E-HyClip DI-V110 IN-E-HyClip DI-V110 Baud rate compatibility requirements RS-485 multi-drop network Ethernet local area networkUSB Example HygroClip DI with USB portSpecifications Communications protocol AccessoriesPower supply wiring Electrical Installation GuidelinesLightning protection Hardware and firmware Document releases

HygroClip DI digital interface specifications

The Digi HygroClip DI is an advanced digital interface designed for precise measurement and control of humidity and temperature in various applications. An integral tool for numerous industries, the HygroClip DI is particularly prized in environmental monitoring, HVAC systems, agriculture, and laboratories, where accurate climate data is essential for operational efficiency and sustainability.

One of the standout features of the Digi HygroClip DI is its exceptional measurement accuracy. The device utilizes a high-performance capacitive sensor for humidity measurement and a precision thermistor for temperature. This combination enables the HygroClip DI to deliver consistent and reliable readings, ensuring that users can trust the data used for critical decision-making processes.

The HygroClip DI incorporates innovative digital signal processing technology. This technology enhances the device's stability and response time, significantly improving performance compared to traditional analog sensors. This digital approach also simplifies integration with other systems, making it an ideal choice for applications requiring connectivity to data loggers, control systems, or telemetry networks.

Another significant characteristic of the HygroClip DI is its robust design. Constructed to withstand demanding environments, the device is both water-resistant and resistant to dust, ensuring that it maintains functionality even in challenging conditions. Its design also allows for easy installation, often requiring minimal effort to mount or connect.

Flexibility is another key advantage of the Digi HygroClip DI. It comes with various calibration options and can accommodate different operating ranges, making it versatile for diverse industrial needs. Users can select calibration settings that best match their specific environment, further enhancing the accuracy and efficiency of the device.

Additionally, the HygroClip DI is equipped with intuitive interfaces for easy operation. With user-friendly software options available, users can easily manage settings, monitor conditions, and analyze data trends. This accessibility makes it suitable for both experienced professionals and newcomers to the field.

Overall, the Digi HygroClip DI embodies a perfect blend of technology, accuracy, and user-friendliness. Its features cater to a wide range of measurement needs, making it an invaluable tool for any professional seeking reliable climatic data in their operations. Whether used in industrial settings or research facilities, the HygroClip DI is a testament to innovation in environmental monitoring technology.