Dell N2048, N3024 manual Primary Mlag Peer Secondary Mlag Peer, Show vpc brief

Page 11

Note: Interfaces used to connect each peer to the partner switch LAG do not need to match on each peer. For instance, in the example above, one partner LAG interface connects to 1/0/47 on the primary peer while the other interface connects to 1/0/11 on the secondary peer.

2.Connect all cables as shown in Figure 4.

3.Run the show vpc brief command on either of the two MLAG peers to see which peer is the primary MLAG peer.

4.Run the show vpc brief command again from the primary switch to display all information for both peers.

Note: The partner switches must be configured with MLAGs and connected to the MLAG peers, or the “Number of VPCs operational” in the show vpc brief command shows 0.

 

 

Primary MLAG Peer

Secondary MLAG Peer

 

 

 

 

show vpc brief

 

 

show vpc brief

 

 

 

 

 

VPC admin status

Enabled

VPC admin status

Enabled

 

 

 

Keep-alive admin status

Enabled

Keep-alive admin status

Enabled

 

 

 

VPC operational status

Enabled

VPC operational status

Enabled

 

 

 

Self role

Primary

Self role

Secondary

 

 

 

Peer role

Secondary

Peer role

Primary

 

 

 

Peer detection admin status

Disabled

Peer detection admin status

Disabled

 

 

 

Peer-Link details

 

 

Peer-Link details

 

 

 

 

 

-----------------

 

 

-----------------

 

 

 

 

 

Interface

Po1

Interface

Po1

 

 

 

Peer-link admin status

Enabled

Peer-link admin status

Enabled

 

 

 

Peer-link STP admin status

Disabled

Peer-link STP admin status

Disabled

 

 

 

Configured VLANs

1,30

Configured VLANs

1,30

 

 

 

Egress tagged VLANs

30

Egress tagged VLANs

30

 

 

 

VPC Details

 

 

VPC Details

 

 

 

 

 

-----------

 

 

-----------

 

 

 

 

 

Number of VPCs configured

2

Number of VPCs configured

2

 

 

 

Number of VPCs operational

2

Number of VPCs operational

2

 

 

 

VPC id# 30

 

 

VPC id# 30

 

 

 

 

 

-----------

 

 

-----------

 

 

 

 

 

Interface

Po30

Interface

Po30

 

 

 

Configured VLANs

1,30

Configured VLANs

1,30

 

 

 

VPC interface state

Active

VPC interface state

Active

 

 

 

Local Members

Status

 

Local Members

Status

 

 

 

 

-----------------

------

 

-----------------

------

 

 

 

 

Gi1/0/47

Up

 

Gi1/0/11

Up

 

 

 

 

Peer Members

Status

 

Peer Members

Status

 

 

 

 

----------------

------

 

----------------

------

 

 

 

 

Gi1/0/11

Up

 

< * run command from Primary for this information >

 

 

 

VPC id# 40

 

 

VPC id# 40

 

 

 

 

 

 

 

 

 

 

 

 

11

Using MLAG in Dell Networks

 

 

 

 

 

 

.

Image 11
Contents Using Mlag in Dell Networks Date Description January Initial Release RevisionsTable of Contents Executive Summary Mlag IntroductionConsistency of Mlag Peers Caveats for Enabling MlagSpecific configuration options to be equal among Mlag peers Topological parameter Supported options Supported TopologiesSingle-Tier Example Partner Switch BPartner a LAG channel-group Partner Switch a Partner Switch B Description of commandsShow vpc brief Primary Mlag Peer Secondary Mlag PeerShow interface port-channel Single-tier Mlag PeerTwo-Tier Example Logical topology of a 2-tier full mesh configurationMlag Peer B Mlag Peer C Description of commands LAG Mlag Peer D Mlag Peer E Description of commandsMlag Partner Switch a Partner Switch F Description of commandsMlag Peer B Primary Peer Mlag Peer C Secondary Peer Mlag Primary Peers only B and D LAG Using Mlag with VLT or Cisco vPCUnsupported LAG configurations Http//delltechcenter.com Additional ResourcesComponent Description Configuration details