Dell N3024, N2048 manual Single-tier Mlag Peer, Show interface port-channel

Page 12

Primary MLAG Peer

Secondary MLAG Peer

-----------

 

-----------

 

Interface

Po40

Interface

Po40

Configured VLANs

1,30

Configured VLANs

1,30

VPC interface state

Active

VPC interface state

Active

Local Members

Status

Local Members

Status

-----------------

------

-----------------

------

Gi1/0/48

Up

Gi1/0/12

Up

Peer Members

Status

Peer Members

Status

----------------

------

----------------

------

Gi1/0/12

Up

< * run command from Primary for this information >

Note: Running the show vpc brief command on the primary shows the complete status of both peer switches. Running the show vpc brief command on the secondary only shows the status of the secondary.

Results of the command should be the same as shown above. All member ports must show “UP”, and the “VPC interface state” must show “Active”. The show interface port-channelis another helpful tool to let you know if the configured LAG ports are up and running. This command can be run on both the primary and secondary peers on a single layer MLAG topology. If correctly configured, the port(s) in the LAG are listed with an Active status. If there are any inactive ports, check for cabling or configuration issues.

Single-tier MLAG Peer

show interface port-channel 40

 

 

Channel

Ports

Ch-Type Hash Type Min-links Local Prf

-------

----------------------------- -------- --------- --------- ----

Po40

Active: Gi1/0/48

Dynamic 7

1

Disabled

Hash Algorithm Type

1 - Source MAC, VLAN, EtherType, source module and port Id

2 - Destination MAC, VLAN, EtherType, source module and port Id 3 - Source IP and source TCP/UDP port

4 - Destination IP and destination TCP/UDP port

5 - Source/Destination MAC, VLAN, EtherType, source MODID/port

6 - Source/Destination IP and source/destination TCP/UDP port

7 - Enhanced hashing mode

12 Using MLAG in Dell Networks

.

Image 12
Contents Using Mlag in Dell Networks Revisions Date Description January Initial ReleaseTable of Contents Executive Summary Introduction MlagCaveats for Enabling Mlag Consistency of Mlag PeersSpecific configuration options to be equal among Mlag peers Supported Topologies Topological parameter Supported optionsPartner Switch B Single-Tier ExamplePartner Switch a Partner Switch B Description of commands Partner a LAG channel-groupPrimary Mlag Peer Secondary Mlag Peer Show vpc briefSingle-tier Mlag Peer Show interface port-channelLogical topology of a 2-tier full mesh configuration Two-Tier ExampleMlag Peer B Mlag Peer C Description of commands Mlag Peer D Mlag Peer E Description of commands LAGPartner Switch a Partner Switch F Description of commands MlagMlag Peer B Primary Peer Mlag Peer C Secondary Peer Mlag Primary Peers only B and D Using Mlag with VLT or Cisco vPC LAGUnsupported LAG configurations Additional Resources Http//delltechcenter.comConfiguration details Component Description