A CoS is defined by the user, whereby packets are related to the same Class of Service. After a packet has been classified, it is assigned to one of the queues. The PowerConnect 2708/2716/2724/2748 system can classify according to IPv4 information (DSCP).
Class Of Service 802.1p Support
The IEEE 802.1p signaling technique is an OSI Layer 2 standard for marking and prioritizing network traffic at the data link/MAC
Ethernet Switch Management Features
Web-Based Management
With a
TFTP Trivial File Transfer Protocol
The PowerConnect 2708/2716/2724/2748 switches support software boot image and software download through TFTP.
Remote Monitoring
Remote Monitoring (RMON) is an extension to the Simple Network Management Protocol (SNMP), which provides network traffic statistics. RMON defines current and historical MAC- layer statistics and control objects, allowing
Port Default Settings
The PowerConnect 2708/2716/2724/2748 devices’s port default settings are as follows:
Function | Default Setting |
Flow Control | Off (disabled on ingress) |
|
|
Backpressure | Off (disabled on ingress) |
|
|
Auto Negotiation Speed | Enabled (1000 Mbps) |
|
|
Auto Negotiation Duplex | Enabled (Full Duplex) |
|
|
MDIX (not | On (relevant to copper ports only) |
|
|
13