Cyclades PR2000 quick installation manual Lmi-typeANSI, Group of four, None Ansi

Page 13

Cyclades-PR2000

Once the console connection is correctly established, a Cyclades banner and login prompt should appear on the terminal screen. If nothing appears, see the first section of the troubleshooting appendix for help. The second step is to log in. The preset super-user user ID is “super” and the corresponding preset password is “surt”. The password should be changed as soon as possible, as described in chapter 10 of the installation manual and at the end of every example in chapter 4. The login prompts and main menu are shown in Figure 3.1.

All menus have the following elements:

Title – In the example in Figure 3.1: “Main Menu”.

Prompt – The text: “Select Option ==>”.

Options –The menu options, which are selected by number.

Router Name – The default is the name of the product. Each router can be renamed by the super user for easier identification.

Menus can also be navigated using a short-cut method. This method must be activated first by choosing a shortcut character (“+” in the example that follows) in the CONFIG =>SYSTEM =>ROUTER DESCRIPTION menu. Typing 4+1+1 at the main-menu prompt, for example, is equivalent to choosing option 4 in the main menu (Debug), then choosing option 1 in the debug menu (Trace), then choosing option 1 in the trace menu (Driver Trace). In addition to menus, some screens have questions with letter choices. In the line below, several elements may be identified:

lmi-type((A)NSI, (G)roup of four, (N)one )[ANSI]:

Parameter description – The name of the parameter to be configured, in this case “lmi-type”.

Options – Legal choices. The letter in parentheses is the letter that selects the corresponding option.

Current value – The option in square brackets is the current value.

Pressing <Enter> without typing a new value leaves the item unchanged.

Chapter 3 - Using CyROS Menus

13

Image 13
Contents Cyclades-PR2000 FCC Warning Statement Cyclades-PR2000 Quick Installation ManualCanadian DOC Notice Table of Contents Index Appendix B Hardware SpecificationsHOW to USE this Manual Installation Assumptions Text Conventions CONFIG=INTERFACE=LConvention Description IconsCyclades Technical Support and Contact Information CONFIGURATION=ALLUSA Cyclades CorporationWhat is in the BOX HOW to Connect the RJ-45 to DB-25 Adapter Cable Login Prompt and Main Menu Using CyROS MenusLmi-typeANSI, Group of four, None Ansi Special Keys CONFIGURATION=TO FlashCyROS Management Utility Cyros Management UtilityCyclades-PR2000 STEP-BY-STEP Instructions for Common Applications Parameter Example Your Application Step ONEIP MTU NATStep Three Step TWOSwan Network Protocol IP Menu Parameters Mlppp Step FourStep SIX Step FiveStep Eight Step SevenStep Nine Instructions for listing the configuration Instructions for creating a backup of the configuration file35 DSU/CSU Example 2 a LAN-to-LAN Example Using Frame Relay10 Ethernet Network Protocol Menu Parameters 11 Swan Physical Menu Parameters 12 Swan Network Protocol IP Menu Parameters LMI Snap IPCIR Dlci 14 DLC Configuration Menu Parameters15 Static Route Menu Parameters Instructions for creating a backup of the configuration file Secondary Backup Link Bandwidth 64 kbps Example 3 Link Backup17 Traffic Control Parameters 18 Addition of the Primary Main Link Swan20 Multilink Circuit Attributes This parameter has no effect for link backup. For load21 Static Backup Route Parameters Instructions for creating a backup of the configuration file Test Boot Code stepEvent CPU LED Morse code What to Do if the Router Does Not Work or Stops WorkingTesting the Ethernet Interface Figure A.3 General Statistics Table Testing the WAN InterfacesCyclades-PR2000 LEDs Cyclades PR2000Power Requirements external DC adapter General SpecificationsPhysical Specifications SafetyWAN Interfaces External InterfacesLAN Interface Console Interface Asynchronous InterfaceStraight-Through Cable CablesFigure B.7 DB-25 M.34 Adaptor DB-25 Female to M.34 Male DB-25 M.34 AdaptorCross Cable ASY/Modem CableGnd Figure B.10 Loopback Connector DB-25 Male DB-25 Loopback ConnectorIndex Cyclades Philippines

PR2000 specifications

The Cyclades PR2000 is a versatile and powerful gateway designed to provide seamless connectivity and management of various network devices. It is particularly favored in environments that require high availability and reliability, such as data centers, enterprise networks, and remote locations.

One of the main features of the Cyclades PR2000 is its robust support for both serial and Ethernet connections. This flexibility allows users to connect legacy devices with serial ports alongside modern Ethernet-enabled equipment. This makes it ideal for organizations transitioning from older technologies while still needing to maintain support for existing infrastructure.

The PR2000 is equipped with advanced remote management capabilities, which includes secure access via SSH and a web-based interface. This enables system administrators to manage devices from anywhere, significantly reducing the need for physical presence at the hardware site. Moreover, it supports SNMP (Simple Network Management Protocol), enhancing monitoring capabilities and allowing easy integration with existing network management systems.

Scalability is another standout characteristic of the Cyclades PR2000. It can support multiple user sessions simultaneously, allowing diverse teams to access multiple devices concurrently without performance degradation. This is particularly beneficial for large enterprises where multiple IT personnel might need to access different systems at the same time.

The device incorporates powerful security features, including user authentication, role-based access control, and full SSL support, ensuring that data transmitted over the network remains protected. It adheres to industry standards for encryption and security protocols, making it a reliable choice for sensitive data transmission in business-critical environments.

The PR2000 is designed with redundancy in mind, featuring failover mechanisms that ensure continuous operation in case of hardware or connection failures. Its reliability is crucial for businesses that depend on uninterrupted access to networked devices.

Additionally, the user-friendly management tools included with the Cyclades PR2000 reduce the learning curve for new users. Its intuitive interface and comprehensive documentation aid in quick deployment and configuration, allowing organizations to harness its capabilities without extensive training.

In summary, the Cyclades PR2000 is an exceptional choice for organizations looking to enhance their network management capabilities. With its flexible connectivity options, advanced security features, remote management capabilities, and scalability, it stands out in the market as a reliable and efficient solution for maintaining and monitoring diverse network environments.