Cyclades PR2000 quick installation manual This parameter has no effect for link backup. For load

Page 36

Cyclades-PR2000

STEP THREE

Up to this point, the configuration can be used either for link back up or for load back up. This example shows link back up, but parameters applicable to load back up will be mentioned when they appear. Complete information on the multilink circuit concept is provided in chapter 4 of the CyROS Reference Guide.

Menu CONFIG=>MULTILINK=>MULTILINK CIRCUIT NUMBER=>CIRCUIT ATTRIBUTES

Parameter

Example

Your Application

Criterion for Traffic

This parameter has no effect for link backup. For load

 

Distribution

backup, Optimal distribution is performed randomly, and the

 

 

packet is forwarded to the interface with the lesser load.

 

 

Address Based distribution is used when the receiver cannot

 

 

reorder packets, and all packets to a certain IP address must

 

 

be sent through the same interface. This distribution method is

 

 

not recommended unless absolutely necessary.

 

Bandwidth Upper

Zero for link backup. For load backup, this defines when load

 

Limit

backup should activate the backup link. It is measured as a

 

 

percentage of the bandwidth defined in step four.

 

Time to Activate

This parameter does not appear for link backup. Time until

 

Backup if Above Limit

backup is activated after main link bandwidth exceeds limit

 

 

defined in last parameter.

 

Bandwidth Lower

This parameter has no effect for link backup. For load

 

Limit

backup, this defines when load backup should deactivate the

 

 

backup link. It is measured as a percentage of the bandwidth

 

 

defined in step four.

 

Time to Deactivate

This parameter does not appear for link backup. Time until

 

Backup if Below Limit

backup is deactivated after main link bandwidth exceeds limit

 

 

defined in last parameter.

 

 

FIGURE 4.20 MULTILINK CIRCUIT ATTRIBUTES

 

Chapter 4 - Step-by-Step Instructions

36

Image 36
Contents Cyclades-PR2000 Cyclades-PR2000 Quick Installation Manual FCC Warning StatementCanadian DOC Notice Table of Contents Appendix B Hardware Specifications IndexHOW to USE this Manual Installation Assumptions CONFIG=INTERFACE=L Text ConventionsConvention Description IconsCONFIGURATION=ALL Cyclades Technical Support and Contact InformationCyclades Corporation USAWhat is in the BOX HOW to Connect the RJ-45 to DB-25 Adapter Cable Using CyROS Menus Login Prompt and Main MenuLmi-typeANSI, Group of four, None Ansi CONFIGURATION=TO Flash Special KeysCyros Management Utility CyROS Management UtilityCyclades-PR2000 STEP-BY-STEP Instructions for Common Applications Step ONE Parameter Example Your ApplicationIP MTU NATStep TWO Step ThreeSwan Network Protocol IP Menu Parameters Step Four MlpppStep Five Step SIXStep Seven Step EightStep Nine Instructions for creating a backup of the configuration file Instructions for listing the configurationExample 2 a LAN-to-LAN Example Using Frame Relay 35 DSU/CSU10 Ethernet Network Protocol Menu Parameters 11 Swan Physical Menu Parameters 12 Swan Network Protocol IP Menu Parameters Snap IP LMICIR 14 DLC Configuration Menu Parameters Dlci15 Static Route Menu Parameters Instructions for creating a backup of the configuration file Example 3 Link Backup Secondary Backup Link Bandwidth 64 kbps17 Traffic Control Parameters Swan 18 Addition of the Primary Main LinkThis parameter has no effect for link backup. For load 20 Multilink Circuit Attributes21 Static Backup Route Parameters Instructions for creating a backup of the configuration file Boot Code step TestWhat to Do if the Router Does Not Work or Stops Working Event CPU LED Morse codeTesting the Ethernet Interface Testing the WAN Interfaces Figure A.3 General Statistics TableCyclades-PR2000 Cyclades PR2000 LEDsGeneral Specifications Power Requirements external DC adapterPhysical Specifications SafetyExternal Interfaces WAN InterfacesLAN Interface Asynchronous Interface Console InterfaceCables Straight-Through CableDB-25 M.34 Adaptor Figure B.7 DB-25 M.34 Adaptor DB-25 Female to M.34 MaleASY/Modem Cable Cross CableGnd DB-25 Loopback Connector Figure B.10 Loopback Connector DB-25 MaleIndex Cyclades Philippines

PR2000 specifications

The Cyclades PR2000 is a versatile and powerful gateway designed to provide seamless connectivity and management of various network devices. It is particularly favored in environments that require high availability and reliability, such as data centers, enterprise networks, and remote locations.

One of the main features of the Cyclades PR2000 is its robust support for both serial and Ethernet connections. This flexibility allows users to connect legacy devices with serial ports alongside modern Ethernet-enabled equipment. This makes it ideal for organizations transitioning from older technologies while still needing to maintain support for existing infrastructure.

The PR2000 is equipped with advanced remote management capabilities, which includes secure access via SSH and a web-based interface. This enables system administrators to manage devices from anywhere, significantly reducing the need for physical presence at the hardware site. Moreover, it supports SNMP (Simple Network Management Protocol), enhancing monitoring capabilities and allowing easy integration with existing network management systems.

Scalability is another standout characteristic of the Cyclades PR2000. It can support multiple user sessions simultaneously, allowing diverse teams to access multiple devices concurrently without performance degradation. This is particularly beneficial for large enterprises where multiple IT personnel might need to access different systems at the same time.

The device incorporates powerful security features, including user authentication, role-based access control, and full SSL support, ensuring that data transmitted over the network remains protected. It adheres to industry standards for encryption and security protocols, making it a reliable choice for sensitive data transmission in business-critical environments.

The PR2000 is designed with redundancy in mind, featuring failover mechanisms that ensure continuous operation in case of hardware or connection failures. Its reliability is crucial for businesses that depend on uninterrupted access to networked devices.

Additionally, the user-friendly management tools included with the Cyclades PR2000 reduce the learning curve for new users. Its intuitive interface and comprehensive documentation aid in quick deployment and configuration, allowing organizations to harness its capabilities without extensive training.

In summary, the Cyclades PR2000 is an exceptional choice for organizations looking to enhance their network management capabilities. With its flexible connectivity options, advanced security features, remote management capabilities, and scalability, it stands out in the market as a reliable and efficient solution for maintaining and monitoring diverse network environments.