Cyclades PR2000 quick installation manual Gnd

Page 51

Cyclades-PR2000

Cross Cable

DB-25 Male

DB-25 Male

Signal

Pin

PGnd

1

TxD

2

RxD

3

RTS

4

CTS

5

Gnd

7

DCD

8

DTR

20

DSR

6

RxD V.35 + (B)

11

TxD V.35 + (B)

13

TxD V.35 - (A)

12

RxD V.35 - (A)

14

TxClk_DTE (A)

15

RxClk

17

TxClk_DCE

24

TxClk_DTE V.35 + (B)

16

RxClk V.35 + (B)

25

TxClk DCE V.35 - (B)

19

TxClk_DTE V.35 - (A)

18

RxClk V.35 - (A)

23

TxClk DCE V.35 - (A)

21

Pin

Signal

1

PGnd

3

RxD

2

TxD

4RTS

5CTS

7Gnd

8DCD

20DTR

6DSR

13RxD V.35 + (B)

11TxD V.35 + (B)

14RxD V.35 - (A)

12TxD V.35 - (A)

24TxD V.35 - (A)

17RxClk

15TxClk DCE

19TxClk_DCE V.35 + (B)

25RxClk V.35 + (B)

16TxClk DTE V.35 - (B)

21TxClk_DCE V.35 - (A)

13RxClk V.35 - (A)

18TxClk DTE V.35 - (A)

FIGURE B.9 CROSS CABLE - DB-25 MALE TO DB-25 MALE

Appendix B - Hardware Specifications

51

Image 51
Contents Cyclades-PR2000 Cyclades-PR2000 Quick Installation Manual FCC Warning StatementCanadian DOC Notice Table of Contents Index Appendix B Hardware SpecificationsHOW to USE this Manual Installation Assumptions Icons CONFIG=INTERFACE=LText Conventions Convention DescriptionCyclades Technical Support and Contact Information CONFIGURATION=ALLUSA Cyclades CorporationWhat is in the BOX HOW to Connect the RJ-45 to DB-25 Adapter Cable Login Prompt and Main Menu Using CyROS MenusLmi-typeANSI, Group of four, None Ansi Special Keys CONFIGURATION=TO FlashCyROS Management Utility Cyros Management UtilityCyclades-PR2000 STEP-BY-STEP Instructions for Common Applications NAT Step ONEParameter Example Your Application IP MTUStep Three Step TWOSwan Network Protocol IP Menu Parameters Mlppp Step FourStep SIX Step FiveStep Seven Step EightStep Nine Instructions for listing the configuration Instructions for creating a backup of the configuration file35 DSU/CSU Example 2 a LAN-to-LAN Example Using Frame Relay10 Ethernet Network Protocol Menu Parameters 11 Swan Physical Menu Parameters 12 Swan Network Protocol IP Menu Parameters Snap IP LMICIR Dlci 14 DLC Configuration Menu Parameters15 Static Route Menu Parameters Instructions for creating a backup of the configuration file Secondary Backup Link Bandwidth 64 kbps Example 3 Link Backup17 Traffic Control Parameters 18 Addition of the Primary Main Link Swan20 Multilink Circuit Attributes This parameter has no effect for link backup. For load21 Static Backup Route Parameters Instructions for creating a backup of the configuration file Test Boot Code stepEvent CPU LED Morse code What to Do if the Router Does Not Work or Stops WorkingTesting the Ethernet Interface Figure A.3 General Statistics Table Testing the WAN InterfacesCyclades-PR2000 LEDs Cyclades PR2000Safety General SpecificationsPower Requirements external DC adapter Physical SpecificationsExternal Interfaces WAN InterfacesLAN Interface Console Interface Asynchronous InterfaceStraight-Through Cable CablesFigure B.7 DB-25 M.34 Adaptor DB-25 Female to M.34 Male DB-25 M.34 AdaptorCross Cable ASY/Modem CableGnd Figure B.10 Loopback Connector DB-25 Male DB-25 Loopback ConnectorIndex Cyclades Philippines

PR2000 specifications

The Cyclades PR2000 is a versatile and powerful gateway designed to provide seamless connectivity and management of various network devices. It is particularly favored in environments that require high availability and reliability, such as data centers, enterprise networks, and remote locations.

One of the main features of the Cyclades PR2000 is its robust support for both serial and Ethernet connections. This flexibility allows users to connect legacy devices with serial ports alongside modern Ethernet-enabled equipment. This makes it ideal for organizations transitioning from older technologies while still needing to maintain support for existing infrastructure.

The PR2000 is equipped with advanced remote management capabilities, which includes secure access via SSH and a web-based interface. This enables system administrators to manage devices from anywhere, significantly reducing the need for physical presence at the hardware site. Moreover, it supports SNMP (Simple Network Management Protocol), enhancing monitoring capabilities and allowing easy integration with existing network management systems.

Scalability is another standout characteristic of the Cyclades PR2000. It can support multiple user sessions simultaneously, allowing diverse teams to access multiple devices concurrently without performance degradation. This is particularly beneficial for large enterprises where multiple IT personnel might need to access different systems at the same time.

The device incorporates powerful security features, including user authentication, role-based access control, and full SSL support, ensuring that data transmitted over the network remains protected. It adheres to industry standards for encryption and security protocols, making it a reliable choice for sensitive data transmission in business-critical environments.

The PR2000 is designed with redundancy in mind, featuring failover mechanisms that ensure continuous operation in case of hardware or connection failures. Its reliability is crucial for businesses that depend on uninterrupted access to networked devices.

Additionally, the user-friendly management tools included with the Cyclades PR2000 reduce the learning curve for new users. Its intuitive interface and comprehensive documentation aid in quick deployment and configuration, allowing organizations to harness its capabilities without extensive training.

In summary, the Cyclades PR2000 is an exceptional choice for organizations looking to enhance their network management capabilities. With its flexible connectivity options, advanced security features, remote management capabilities, and scalability, it stands out in the market as a reliable and efficient solution for maintaining and monitoring diverse network environments.