CYV15G0101EQ
Maximum Ratings
Exceeding maximum ratings may shorten the useful life of the device. These user guidelines are not tested.
Storage Temperature | |
Ambient Temperature with |
|
Power Applied | |
Supply Voltage to Ground Potential | |
DC Voltage Applied to Outputs |
|
in High Z State | |
DC Input Voltage | |
Electro Static Discharge (ESD) HBM | > 2000 V |
(JEDEC |
|
Latch Up Current | > 200 mA |
DC Electrical Characteristics
Power Up Requirements
The CYV15G0101EQ contains one power supply. The voltage on any input or IO pin must not exceed the power pin during power up.
Operating Range
Range | Ambient | VCC |
Temperature | ||
Commercial | 0°C to +70°C | +3.3V ±5% |
|
|
|
Parameter |
|
| Description | Test Conditions | Min | Typ | Max | Unit | ||
VCC |
| Supply Voltage[1] | – | 3.135 | 3.3 | 3.465 | V | |||
PD |
| Power Consumption[2] | – | 125 | 160 | 190 | mW | |||
I |
| Supply Current[1] | – | 38 | 48 | 60 | mA | |||
S |
|
|
|
|
|
|
|
| ||
VCMOUT |
| Output Common Mode Voltage[1] | Load = 50Ω | – | VCC – | – | V | |||
|
|
|
|
|
|
|
| ΔVSDO/2 = 2.9 |
|
|
VCMIN |
| Input Common Mode Voltage[1] | – | 1 |
| 1.4 | V | |||
|
|
|
| (Bypass = High) |
|
|
|
|
| |
|
|
|
| Input Common Mode Voltage[1] | – | 0 |
| 2.9 | V | |
|
|
|
| (Bypass = Low) |
|
|
|
|
| |
– |
| CLI DC Voltage (0m)[1] | – | 2.2 | 2.65 | 2.95 | V | |||
– |
| CLI DC Voltage (No Signal)[1] | – | 1.5 | 1.9 | 2.3 | V | |||
– |
| Floating MCLADJ DC Voltage[1] | – |
| 1.3 |
| V | |||
– |
| MCLADJ Range[3] | – | 0.4 | 0.72 | 1.02 | V | |||
V |
| CD/MUTE(OH) |
|
|
| Carrier Not Present | 2.8 | – | – | V |
| CD/MUTE Output Voltage[1] | |||||||||
| ||||||||||
V |
| CD/MUTE(OL) |
|
|
| Carrier Present | – | – | 0.8 | V |
|
|
| ||||||||
V |
|
|
|
|
| Min to Mute | 2.5 | – | – | V |
|
|
| CD/MUTE Input Voltage Required to | |||||||
CD/MUTE |
| |||||||||
|
|
|
| Force Outputs to Mute[1] |
|
|
|
|
| |
V |
|
|
|
|
| Max to Activate | – | – | 1 | V |
|
|
| CD/MUTE Input Voltage Required to | |||||||
CD/MUTE |
| |||||||||
|
|
|
| Force Active[1] |
|
|
|
|
|
Notes
1.Production test.
2.Calculated results from production test.
3.Not tested. Based on characterization.
Document Number: | Page 5 of 10 |