Dell 2.3 manual Understanding Omsa For 11th Generation Dell PowerEdge Hosts

Page 35

Post only Virtualization-Related Critical and Warning Events

Post Virtualization related events received from hosts into related vCenters. Virtualization related events are those that Dell has selected to be most critical to hosts running virtual machines.

When you configure your events and alarms, you can enable them. When enabled, critical hardware alarms can trigger the OpenManage Integration for VMware vCenter to put the host system into a maintenance mode, and in certain cases, migrate the virtual machines to another host system. The OpenManage Integration for VMware vCenter forwards events received from managed Dell hosts, and creates alarms for those events. Use these alarms to trigger actions from vCenter, like a reboot, maintenance mode, or migrate. For example, when a dual power supply fails and an alarm is created, the resulting action is to migrate the virtual machine on that machine to a new one.

A host enters or leaves maintenance mode only as when you request it. If the host is in a cluster when it enters maintenance mode, you are given the option to evacuate powered-off virtual machines. If this option is selected, each powered-off virtual machine is migrated to another host, unless there is no compatible host available for the virtual machine in the cluster. While in maintenance mode, the host does not allow deployment or power-onof a virtual machine. Virtual machines that are running on a host entering maintenance mode need to be either migrated to another host or shut down, either manually or automatically by VMware Distributed Resource Scheduling (DRS).

Any hosts outside of clusters, or in clusters without VMware Distributed Resource Scheduling (DRS) enabled, could see virtual machines being shut down due to a critical event. DRS continuously monitors usage across a resource pool and intelligently allocates available resources among virtual machines according to business needs. Use clusters with DRS configured in conjunction with Dell Alarms to make sure that virtual machines are automatically migrated on critical hardware events. Listed in the details of the on screen message are any clusters on this vCenter instance that may be impacted. Confirm that the clusters are impacted before enabling Events and Alarms.

If you ever need to restore the default alarm settings, you can do so with the Reset Default Alarm button. This button is a convenience to restore the default alarm configuration without uninstalling and reinstalling the product. If any Dell alarm configurations have been changed since install, those changes are reverted using this button.

NOTE: To receive Dell events, you must enable the events.

NOTE: The OpenManage Integration for VMware vCenter pre-selects the virtualization-related events that are the essential to hosts successfully running virtual machines. Dell host alarms are disabled by default. If Dell alarms are enabled, the clusters should use the VMware Distributed Resource Scheduler to make sure that the virtual machines that send critical events are automatically migrated.

Understanding OMSA For 11th Generation Dell PowerEdge Hosts

On PowerEdge servers earlier than 12th generation, it is mandatory to install OMSA to work with the OpenManage Integration for VMware vCenter. OMSA is installed automatically on 11th generation Dell PowerEdge hosts during deployment, or if you want to install it manually, you may still do so.

NOTE: When deploying the OMSA agent using the OpenManage Integration for VMware vCenter starts the httpClient service and enables port 8080 on and releases after ESXi 5.0 to download OMSA VIB and install it. Once the OMSA installation is completed, the service automatically stops and the port is closed.

To configure OMSA on 11th generation Dell PowerEdge servers, choose from the following:

Deploying an OMSA Agent Onto ESXi System

Deploying an OMSA Agent Onto ESX System

Setting Up An OMSA Trap Destination

Deploying the OMSA Agent onto an ESX System

Install the OMSA tar.gz on an ESX system to gather inventory and alert information from the systems.

35

Image 35
Contents Page Page Contents Hardware Management End-To-End Hardware ManagementViewing Or Editing Hypervisor Profiles Console AdministrationConfiguring Network Settings Troubleshooting101 104 Dell platforms Key FeaturesOpenManage Integration for VMware vCenter InventoryOpenManage Integration for VMware vCenter Features Data Integrity Security Roles and PermissionsDell.Inventory Access Control Authentication, Authorization, And RolesDell Operation Role Dell Infrastructure Deployment RoleDell.Deploy Understanding PrivilegesPage Page Configuration Tasks Using the Configuration Wizard Creating a New Connection Profile Wizard Configuration Wizard WelcomeOpenManage Integration for VMware vCenter Home Configuring Events And Alarms Wizard Enter the Proxy Port number Setting Up a Proxy Server WizardScheduling Inventory Jobs Wizard Configuring the Deployment Credentials Wizard Running a Warranty Retrieval Job WizardEnabling The Omsa Link Wizard Setting The Default Firmware Update Repository WizardGeneral Settings Overview Configuring NFS SharesSettings Overview Creating a New Connection Profile Enabling The Omsa Link Outside the Configuration WizardEnable or Disable Server Warranty Expiration Notification To create a new connection profile Configuring Events And Alarms Setting Up a Proxy Server About Proxy ConfigurationRunning Inventory Jobs Running a Warranty Retrieval JobUsing The Http Proxy For Retrieving Web Based Data Dell Management Center, select Settings → Warranty ScheduleClick Begin Test Setting Up The Firmware RepositoryViewing or Editing Deployment Credentials Dell Online Shared Network FolderAdding Deployable Servers To a White List Server Security Settings For DeploymentEnabling a Deployable Server White List Related Information About Host, Bare Metal, and iDRAC Compliance IssuesRunning The Fix Non-Compliant vSphere Hosts Wizard Deleting Deployable Servers From a White ListRunning The Fix Non-Compliant Bare Metal Server Wizard Re-checking Bare Metal Server Compliance Downloading An ISO For Manual Firmware UpdatesIDRAC License Compliance Upgrading From a Trial Version To a Full Product Version Upgrading OpenManage Integration for VMware vCenterAbout OpenManage Integration for VMware vCenter Licensing Event Description Understanding Events And AlarmsConfigure Snmp Omsa trap destinations, if needed Monitoring the Datacenter And Host SystemDeploying the Omsa Agent onto an ESX System Understanding Omsa For 11th Generation Dell PowerEdge HostsClick Apply Changes Deploying The Omsa Agent Onto An ESXi SystemHost Information VSphere Client Host OverviewViewing Events Management Consoles Dell Online ServicesHost Actions Modifying An Inventory Job Schedule Resetting iDRACUnder Host Actions, select iDRAC Reset About Inventory ScheduleDisplaying The Inventory For a Single Host System in vCenter To update the Details of Last Inventory Job, click RefreshInventory And Licensing Viewing Storage Inventory Viewing Host Power MonitoringManaging Connection Profiles Viewing Or Editing An Existing Connection Profile Deleting a Connection Profile Testing a Connection ProfileDisplaying Logs in Dell Management Center Understanding System Event Logs In vSphere Client Host ViewRefreshing a Connection Profile Shared Network About Firmware UpdatesDisplaying The Event Logs For An Individual Host Dell ftp.dell.comFirmware Versions Older than July 29 Running The Firmware Update WizardSelect Update from repository Firmware Versions After October 14Updating Older Firmware Versions Enter maintenance mode, apply updates, and restartApply updates on next reboot Click Update Firmware Viewing Firmware Update Status for Clusters and Datacenters Advanced Host Management Using vCenterServer Based Management Tools Setting Up Physical Server Front Indicator LightWarranty Retrieval Under Host Actions, select Blink Indicator LightViewing Server Warranty Information For a Single Host Prerequisites Hardware ManagementServer States Within The Deployment Sequence Provisioning OverviewUnderstanding Deployment Job Times Downloading Custom Dell ISO Images Understanding How To Configure a Hardware ProfileCreating a New Hardware Profile ConfigurationPage Remotely Cloning a Hardware ProfileEnabling Csior On a Reference Server LocallyRenaming a Hardware Profile About Managing Hardware ProfilesViewing Or Editing a Hardware Profile Duplicating a Hardware ProfileCreating a New Hypervisor Profile Refreshing An Updated Hardware ProfileVlan Support Managing Hypervisor ProfilesDuplicating a Hypervisor Profiles Viewing Or Editing Hypervisor ProfilesRefreshing Hypervisor Profiles Building a New Deployment TemplateRenaming Hypervisor Profile Deleting a Hypervisor ProfileRenaming a Deployment Template Running The Deployment WizardDuplicating Deployment Templates Deleting a Deployment TemplateDeployment Wizard Deployment Templates Deployment Wizard Global SettingsDeployment Wizard Select Servers Deployment Wizard Server Identification Click Schedule servers for deployment Deployment Wizard Connection ProfileDeployment Wizard Scheduling Jobs Understanding Job QueueOn the Select Server tab, click Add Server Managing Deployment Jobs Using The Deployment Job QueueAdding a Server Manually Click Remove Selected Servers Removing a Bare Metal ServerOn the Select Servers tab, click Remove Servers Registering a vCenter Server Web-based Administration ConsoleManaging vCenter Server Connections VCenter sSupport OpenManage Integration for VMware vCenter RequirementsClick Register Versions of ESXi that should be supported on hosts managedUpdating The SSL Certificates For Registered vCenter Servers Modifying The vCenter Administrator LoginUpdating a Repository Location And Virtual Appliance Virtual Appliance ManagementRestarting The Virtual Appliance Updating the Virtual Appliance Software Version Downloading the Troubleshooting BundleSetting Up The Http Proxy Setting Up the NTP ServersUploading an Https Certificate Restoring the Default Https CertificateClick Restore Default Certificate for Https Certificates Generating a Certificate Signing RequestConfiguring Backup And Restore Setting up Global AlertsManaging Backup And Restore Click Backup Now Scheduling Automatic BackupsPerforming An Immediate Backup Restoring The Database From a BackupUnderstanding the vSphere Client Console Configuring Network SettingsChanging The Virtual Appliance Password Enter the Current Admin Password and press EnterRefreshing the Console View Setting The Local Time ZoneRebooting Virtual Appliance Resetting The Virtual Appliance To Factory SettingsMigration Path to migrate from 1.6/1.7 to Power on the OpenManage Integration version 2.3 applianceFrequently Asked Questions FAQ TroubleshootingVersion Affected All Firmware link communication error FTP TCP Rmcp UDP/TCP Select Temperatures under Main System Chassis Select the Enable Platform Event Filter Alerts check boxWhen I tried to use lockdown mode, it failed Go to https//vcenterserverIPAddress/mob Set UserVars.CIMoemProviderEnabled toHow Do I Force Removal of the Virtual Appliance? My vCenter Registration Failed. What Can I Do? My Firmware Update Failed. What Do I Do?Auto-Discovery and Handshake Prerequisites Bare Metal Deployment IssuesHardware Configuration Failure Enabling Auto-Discovery On a Newly Purchased SystemContacting Dell Event Name Description Severity Virtualization-related Events For Dell PowerEdge ServersNo action Dell Memory Device Dell Processor sensor Error Threshold value Independent error condition Dell Storage Controller Dell Storage Array disk Array disk warning Dell Watchdog Power Watchdog Power cycle Error Module information Information Dell Integrated Dual SD Auto-Discovery Prerequisites Understanding Auto-DiscoveryYou must have the iDRAC and host IP addresses Log in to the Integrated Dell Remote Access Controller GUIEnter the iDRAC IP address into a browser You must have the iDRAC and host IP addresses