Why is the processor version “Not Applicable” in Processor view in the System overview page?

In case of PowerEdge 12th Generation Dell Servers and higher generations, the processor version is in the Brand column. In case of lower generation servers processor version is shown in the Version column.

Why is the DNS configuration settings restored to original settings after appliance reboot if using DHCP for appliance IP and DNS settings overwritten

There is a known defect where statically assigned DNS settings are replaced by values from DHCP. This can happen when DHCP is used to obtain IP settings, and DNS values are assigned statically. When the DHCP lease is renewed or the appliance is restarted the statically assigned DNS settings are removed. Resolution: Statically assign IP settings when the DNS server settings will be different from DHCP.

Version Affected: All

How come I do not see my new iDRAC version details listed on the vCenter Hosts & Clusters page?

After the successful completion of a firmware update task in the vSphere Desktop client’s recent tasks pane, refresh the Firmware Update page and verify the firmware versions. If the page shows the old versions, then go to Host Compliance page in OpenManage Integration for VMware vCenter and check the CISOR status of that host. If CISOR is not enabled, then enable CISOR and reboot host. If the CISOR was already enabled, then login to the iDRAC console, reset iDRAC, wait for few minutes, and then refresh the Firmware Update page in vSphere Desktop client.

How Do I Test Event Settings by Using OMSA to Simulate a Temperature Hardware Fault?

To make sure that events are functioning correctly:

1.In the OMSA user interface, navigate to Alert Management Platform Events.

2.Select the Enable Platform Event Filter Alerts check box.

3.Scroll down to the bottom, and click Apply Changes.

4.To make sure that a specific event is enabled, such as temperature warning, from the tree on the left, select Main System Chassis.

5.Under Main System Chassis, select Temperatures.

6.Select the Alert Management tab, and select Temperature Probe Warning.

7.Select the Broadcast a Message check box, and select Apply Changes.

8.To cause the temperature warning event, from the tree view on the left, select Main System Chassis.

9.Select Temperatures under Main System Chassis.

10.Select the System Board Ambient Temp link, and select the Set to Values option button.

11.Set the Maximum Warning Threshold to below the current listed reading; for example if the current reading is 27, set the threshold to 25.

12.Select Apply Changes, and the temperature warning event is generated. To cause another event, restore the original settings using the same Set to Values option. Events are generated as warnings, and then to a normal state. If everything is working properly, navigate to the vCenter Tasks & Events view; a temperature probe warning event should be displayed.

NOTE: There is a filter for duplicate events; if you try to trigger the same event too many times in a row, you will only receive one event. Allow at least 30 seconds between events to see all events.

87

Image 87
Contents Page Page Contents Hardware Management End-To-End Hardware ManagementViewing Or Editing Hypervisor Profiles Console AdministrationConfiguring Network Settings Troubleshooting101 104 Dell platforms Key FeaturesOpenManage Integration for VMware vCenter InventoryOpenManage Integration for VMware vCenter Features Data Integrity Security Roles and PermissionsDell.Inventory Access Control Authentication, Authorization, And RolesDell Operation Role Dell Infrastructure Deployment RoleDell.Deploy Understanding PrivilegesPage Page Configuration Tasks Using the Configuration Wizard Configuration Wizard Welcome OpenManage Integration for VMware vCenter HomeCreating a New Connection Profile Wizard Configuring Events And Alarms Wizard Setting Up a Proxy Server Wizard Scheduling Inventory Jobs WizardEnter the Proxy Port number Configuring the Deployment Credentials Wizard Running a Warranty Retrieval Job WizardEnabling The Omsa Link Wizard Setting The Default Firmware Update Repository WizardConfiguring NFS Shares Settings OverviewGeneral Settings Overview Enabling The Omsa Link Outside the Configuration Wizard Enable or Disable Server Warranty Expiration NotificationCreating a New Connection Profile To create a new connection profile Configuring Events And Alarms Setting Up a Proxy Server About Proxy ConfigurationRunning Inventory Jobs Running a Warranty Retrieval JobUsing The Http Proxy For Retrieving Web Based Data Dell Management Center, select Settings → Warranty ScheduleClick Begin Test Setting Up The Firmware RepositoryViewing or Editing Deployment Credentials Dell Online Shared Network FolderServer Security Settings For Deployment Enabling a Deployable Server White ListAdding Deployable Servers To a White List Related Information About Host, Bare Metal, and iDRAC Compliance IssuesRunning The Fix Non-Compliant vSphere Hosts Wizard Deleting Deployable Servers From a White ListRunning The Fix Non-Compliant Bare Metal Server Wizard Downloading An ISO For Manual Firmware Updates IDRAC License ComplianceRe-checking Bare Metal Server Compliance Upgrading OpenManage Integration for VMware vCenter About OpenManage Integration for VMware vCenter LicensingUpgrading From a Trial Version To a Full Product Version Event Description Understanding Events And AlarmsConfigure Snmp Omsa trap destinations, if needed Monitoring the Datacenter And Host SystemDeploying the Omsa Agent onto an ESX System Understanding Omsa For 11th Generation Dell PowerEdge HostsClick Apply Changes Deploying The Omsa Agent Onto An ESXi SystemVSphere Client Host Overview Viewing EventsHost Information Dell Online Services Host ActionsManagement Consoles Modifying An Inventory Job Schedule Resetting iDRACUnder Host Actions, select iDRAC Reset About Inventory ScheduleDisplaying The Inventory For a Single Host System in vCenter To update the Details of Last Inventory Job, click RefreshInventory And Licensing Viewing Storage Inventory Viewing Host Power MonitoringManaging Connection Profiles Viewing Or Editing An Existing Connection Profile Deleting a Connection Profile Testing a Connection ProfileUnderstanding System Event Logs In vSphere Client Host View Refreshing a Connection ProfileDisplaying Logs in Dell Management Center Shared Network About Firmware UpdatesDisplaying The Event Logs For An Individual Host Dell ftp.dell.comFirmware Versions Older than July 29 Running The Firmware Update WizardSelect Update from repository Firmware Versions After October 14Enter maintenance mode, apply updates, and restart Apply updates on next rebootUpdating Older Firmware Versions Click Update Firmware Viewing Firmware Update Status for Clusters and Datacenters Advanced Host Management Using vCenterServer Based Management Tools Setting Up Physical Server Front Indicator LightWarranty Retrieval Under Host Actions, select Blink Indicator LightViewing Server Warranty Information For a Single Host Prerequisites Hardware ManagementProvisioning Overview Understanding Deployment Job TimesServer States Within The Deployment Sequence Downloading Custom Dell ISO Images Understanding How To Configure a Hardware ProfileCreating a New Hardware Profile ConfigurationPage Remotely Cloning a Hardware ProfileEnabling Csior On a Reference Server LocallyRenaming a Hardware Profile About Managing Hardware ProfilesViewing Or Editing a Hardware Profile Duplicating a Hardware ProfileCreating a New Hypervisor Profile Refreshing An Updated Hardware ProfileVlan Support Managing Hypervisor ProfilesDuplicating a Hypervisor Profiles Viewing Or Editing Hypervisor ProfilesRefreshing Hypervisor Profiles Building a New Deployment TemplateRenaming Hypervisor Profile Deleting a Hypervisor ProfileRenaming a Deployment Template Running The Deployment WizardDuplicating Deployment Templates Deleting a Deployment TemplateDeployment Wizard Global Settings Deployment Wizard Select ServersDeployment Wizard Deployment Templates Deployment Wizard Server Identification Click Schedule servers for deployment Deployment Wizard Connection ProfileDeployment Wizard Scheduling Jobs Understanding Job QueueManaging Deployment Jobs Using The Deployment Job Queue Adding a Server ManuallyOn the Select Server tab, click Add Server Removing a Bare Metal Server On the Select Servers tab, click Remove ServersClick Remove Selected Servers Web-based Administration Console Managing vCenter Server ConnectionsRegistering a vCenter Server VCenter sSupport OpenManage Integration for VMware vCenter RequirementsClick Register Versions of ESXi that should be supported on hosts managedUpdating The SSL Certificates For Registered vCenter Servers Modifying The vCenter Administrator LoginVirtual Appliance Management Restarting The Virtual ApplianceUpdating a Repository Location And Virtual Appliance Updating the Virtual Appliance Software Version Downloading the Troubleshooting BundleSetting Up The Http Proxy Setting Up the NTP ServersUploading an Https Certificate Restoring the Default Https CertificateClick Restore Default Certificate for Https Certificates Generating a Certificate Signing RequestSetting up Global Alerts Managing Backup And RestoreConfiguring Backup And Restore Click Backup Now Scheduling Automatic BackupsPerforming An Immediate Backup Restoring The Database From a BackupUnderstanding the vSphere Client Console Configuring Network SettingsChanging The Virtual Appliance Password Enter the Current Admin Password and press EnterRefreshing the Console View Setting The Local Time ZoneRebooting Virtual Appliance Resetting The Virtual Appliance To Factory SettingsMigration Path to migrate from 1.6/1.7 to Power on the OpenManage Integration version 2.3 applianceFrequently Asked Questions FAQ TroubleshootingVersion Affected All Firmware link communication error FTP TCP Rmcp UDP/TCP Select Temperatures under Main System Chassis Select the Enable Platform Event Filter Alerts check boxWhen I tried to use lockdown mode, it failed Set UserVars.CIMoemProviderEnabled to How Do I Force Removal of the Virtual Appliance?Go to https//vcenterserverIPAddress/mob My vCenter Registration Failed. What Can I Do? My Firmware Update Failed. What Do I Do?Auto-Discovery and Handshake Prerequisites Bare Metal Deployment IssuesHardware Configuration Failure Enabling Auto-Discovery On a Newly Purchased SystemContacting Dell Event Name Description Severity Virtualization-related Events For Dell PowerEdge ServersNo action Dell Memory Device Dell Processor sensor Error Threshold value Independent error condition Dell Storage Controller Dell Storage Array disk Array disk warning Dell Watchdog Power Watchdog Power cycle Error Module information Information Dell Integrated Dual SD Auto-Discovery Prerequisites Understanding Auto-DiscoveryYou must have the iDRAC and host IP addresses Log in to the Integrated Dell Remote Access Controller GUIEnter the iDRAC IP address into a browser You must have the iDRAC and host IP addresses