Furuno FE-700 manual Picture Advance, Trend, Interval

Page 20

2.4 Picture Advance

The picture advance speed determines how quickly the vertical scan lines run across the screen.

1.Select MENU with the MODE Selector.

2.Select PICTURE ADVANCE by pressing the [▲] or [▼] key.

3.Press the [+] or [-] key to select speed FAST or SLOW, respectively. The advance speed varies with the range scale and the viewing length of 15-16 minutes is available on all ranges (IMO requirements).

Range (m)

Display window (minute)

5, 10, 20

1.8/15

(FAST/SLOW)

40,100

8/15

 

200

15/20

 

400, 800

15/30

 

2.5 Trend

The future trend of the seabed depths can be predicted over a specified period of time (See page 13). The trend index is set with the item TREND and appears at the top left corner. The default setting is ON.

θis inclination angle of bottom.

2.6 Interval

The interval for sampling data for the LOGBOOK and HISTORY modes can be set with INTERVAL, among 5 s, 1 min and 2 min. The default setting is 1 min.

 

 

3/60

TIME

DEPTH

L/L

11:00:00

47.5

36°55.012’N

 

 

135°23.123’E

11:01:00

47.5

36°55.012’N

 

 

135°23.123’E

11:02:00

47.5

36°55.013’N

 

 

135°23.123’E

11:03:00

47.5

36°55.013’N

 

 

135°23.123’E

11:04:00

47.5

36°55.014’N

 

 

135°23.123’E

11:05:00

47.5

36°55.014’N

 

 

135°23.123’E

 

 

 

In this example, the setting of INTERVAL is

1 minute. That is, the depth and lat/long data are displayed at 1 minute intervals.

−2°≤θ≤

 

2°<θ≤10° 10°<θ≤4

45°<θ≤90°

−2°>θ≥−10° −10°>θ≥−45° −45°>θ≥−9

10

Image 20
Contents Navigational Echo Sounder Pub. No. OME-23660 Yosh FE-700 DECSafety Instructions Record of Modifications in this OPERATOR’S Manual MENU3Contents Word to FE-700 Owners FeaturesForeword System Configuration Display UnitSpecifications of Navigational Echo Sounder E2366S01QGGA L/L IPX5GLL L/L Power Supply Operation Control DescriptionIndications, Markers Panel Dimmer ROM OK Dram OK Sram OK Battery OKTurning On/Off Tone and Brilliance Display Mode NAV modeDBS mode History modeLogbook mode OS Data modeMenu display Help displayHow to enable/disable automatic operation Range ScaleGain Control Automatic OperationShallow Depth Alarm Activating/deactivating the alarmAcknowledging the alarm DraftMenu Operation Menu OverviewSuppressing Low Level Noise Suppressing InterferenceInterval Picture AdvanceTrend System Menu System MenuOutput Input System Menu Echo Quality Setting Transducer SettingDemonstration Display DEMONSTRATION. DemonstrationEcho Offset Bottom LevelTVG Level Operation of Digital Depth Indicator FE-720 Option Adjusting panel dimmerAdjusting Contrast Basic OperationMenu Operation Dimmer controlSelecting language Selecting the unit of depth measurementFactory Setting AlarmDiagnosis OFFMAINTENANCE, Troubleshooting Transducer MaintenanceCleaning the Display Unit Replacing the Fuse, BatteryTroubleshooting Symptom Probable Causes RemedyDiagnostic Test Test PatternBlack WhiteDON’T Turn Power OFF Until Completed Memory Clear Clearing the MemoryExtension Mode Menu TreeDigital Interface IEC 61162-1 Edition O SentencesRMA, RMC, GLL, GGA, VTG, ZDA DBT, DPT, DBS NmeaSchematic Diagrams NAV in port listenerSentence Description DPT DepthDBS Depth below surface DBT Depth below transducerGLL Geographic position latitude/longitude GGA Global positioning system GPS fix data RMA Recommended minimum specific LORAN-C data RMC Recommended specific GPS/TRANSIT data VTG- Course over ground and ground speed ZDA Time and dateParts LOCATION, Parts List Furuno Code No