Furuno FE-700 Digital Interface IEC 61162-1 Edition, O Sentences, Rma, Rmc, Gll, Gga, Vtg, Zda

Page 34

8DIGITAL INTERFACE (IEC 61162-1 EDITION 2)

1. I/O Sentences

Input sentences of channel 1 (NAV IN)

RMA, RMC, GLL, GGA, VTG, ZDA

Output sentences of channel 2 (NAV OUT)

DBT, DPT, DBS (NMEA 0183)

Transmission interval

1 s for any sentence

Data transmission

Data is transmitted in serial asynchronous form in accordance with the standard referenced in 2.1 of IEC 61162-1. The first bit is a start bit and is followed by data bits, least-significant-bit as illustrated below.

The following parameters are used: Baud rate: 4800

Data bits: 8 (D7 = 0), parity none

Stop bits: 1

 

 

 

 

D0

D1

D2

D3

D4

D5

D6

D7

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Start

 

 

 

 

 

 

 

 

 

Stop

 

 

 

 

 

 

Data bits

 

 

 

 

 

 

 

bit

 

 

 

 

 

 

bit

 

 

24

Image 34
Contents Navigational Echo Sounder Pub. No. OME-23660 Yosh FE-700 DECSafety Instructions Record of Modifications in this OPERATOR’S Manual MENU3Contents Foreword FeaturesWord to FE-700 Owners System Configuration Display UnitSpecifications of Navigational Echo Sounder E2366S01QGLL L/L IPX5GGA L/L Power Supply Operation Control DescriptionIndications, Markers Turning On/Off Tone and Brilliance ROM OK Dram OK Sram OK Battery OKPanel Dimmer DBS mode Display ModeNAV mode History modeLogbook mode OS Data modeMenu display Help displayGain Control How to enable/disable automatic operationRange Scale Automatic OperationAcknowledging the alarm Shallow Depth AlarmActivating/deactivating the alarm DraftSuppressing Low Level Noise Menu OperationMenu Overview Suppressing InterferenceTrend Picture AdvanceInterval System Menu System MenuOutput Input System Menu Demonstration Display Echo Quality SettingTransducer Setting DEMONSTRATION. DemonstrationTVG Level Bottom LevelEcho Offset Adjusting Contrast Operation of Digital Depth Indicator FE-720 OptionAdjusting panel dimmer Basic OperationSelecting language Menu OperationDimmer control Selecting the unit of depth measurementDiagnosis Factory SettingAlarm OFFCleaning the Display Unit MAINTENANCE, TroubleshootingTransducer Maintenance Replacing the Fuse, BatteryTroubleshooting Symptom Probable Causes RemedyBlack Diagnostic TestTest Pattern WhiteDON’T Turn Power OFF Until Completed Memory Clear Clearing the MemoryExtension Mode Menu TreeRMA, RMC, GLL, GGA, VTG, ZDA Digital Interface IEC 61162-1 EditionO Sentences DBT, DPT, DBS NmeaSchematic Diagrams NAV in port listenerDBS Depth below surface Sentence DescriptionDPT Depth DBT Depth below transducerGLL Geographic position latitude/longitude GGA Global positioning system GPS fix data RMA Recommended minimum specific LORAN-C data RMC Recommended specific GPS/TRANSIT data VTG- Course over ground and ground speed ZDA Time and dateParts LOCATION, Parts List Furuno Code No
Related manuals
Manual 60 pages 55.01 Kb