Furuno FE-700 manual System Menu

Page 23

SYSTEM MENU 2

MENU SELECT

1

2

3

 

 

 

TIME ADJUST

INTERNAL

EXTERNAL

TIME DIFFERENCE

AUTO

 

MANUAL

 

TIME DIFF HOUR 0

(0

13)

 

 

 

TIME DIFF MIN

0

(0

59)

 

 

 

TIME DIFF SIGN

- , +

 

 

 

0:22:40

▼▲: To select item

-+: To set option Select other mode to exit.

3.4 System Menu 3

RANGE 1- 8: Activates or deactivates specific range scales. Default ranges are 5, 10, 20, 40, 100, 200, 400, and 800 (meters). Setting area is 2 m to 800 m. The ranges 20 m and 200 m can not be changed. They are essential in this equipment.

Note: Ranges must be set in numerical order. For example, if range 1 is 5 m and range 3 is 20 m, range 2 should be between 6 and 19 m.

Trend: The trend index shows the probable bottom shape over a specified time within 1-10 minutes. The default setting is 1 minute.

Set the Trend time with [+] or [-].

13

Image 23
Contents Navigational Echo Sounder DEC Pub. No. OME-23660 Yosh FE-700Safety Instructions MENU3 Record of Modifications in this OPERATOR’S ManualContents Word to FE-700 Owners FeaturesForeword Display Unit System ConfigurationE2366S01Q Specifications of Navigational Echo SounderGGA L/L IPX5GLL L/L Power Supply Control Description OperationIndications, Markers Panel Dimmer ROM OK Dram OK Sram OK Battery OKTurning On/Off Tone and Brilliance History mode Display ModeNAV mode DBS modeOS Data mode Logbook modeHelp display Menu displayAutomatic Operation How to enable/disable automatic operationRange Scale Gain ControlDraft Shallow Depth AlarmActivating/deactivating the alarm Acknowledging the alarmSuppressing Interference Menu OperationMenu Overview Suppressing Low Level NoiseInterval Picture AdvanceTrend System Menu System MenuOutput Input System Menu DEMONSTRATION. Demonstration Echo Quality SettingTransducer Setting Demonstration DisplayEcho Offset Bottom LevelTVG Level Basic Operation Operation of Digital Depth Indicator FE-720 OptionAdjusting panel dimmer Adjusting ContrastSelecting the unit of depth measurement Menu OperationDimmer control Selecting languageOFF Factory SettingAlarm DiagnosisReplacing the Fuse, Battery MAINTENANCE, TroubleshootingTransducer Maintenance Cleaning the Display UnitSymptom Probable Causes Remedy TroubleshootingWhite Diagnostic TestTest Pattern BlackClearing the Memory DON’T Turn Power OFF Until Completed Memory ClearMenu Tree Extension ModeDBT, DPT, DBS Nmea Digital Interface IEC 61162-1 EditionO Sentences RMA, RMC, GLL, GGA, VTG, ZDANAV in port listener Schematic DiagramsDBT Depth below transducer Sentence DescriptionDPT Depth DBS Depth below surfaceGLL Geographic position latitude/longitude GGA Global positioning system GPS fix data RMA Recommended minimum specific LORAN-C data RMC Recommended specific GPS/TRANSIT data ZDA Time and date VTG- Course over ground and ground speedParts LOCATION, Parts List Code No Furuno
Related manuals