DEPTH UNIT: Selects unit of depth measurement among meters, feet, or fathoms. Default setting is meters.

If "ft" or "fa" is selected, the depth unit is shown in red characters.

SPEED UNIT: Selects unit of speed measurement among knots, statute miles per hour, or kilometers per hour. Default setting is knots. Requires speed data, from external device.

COURSE: Selects heading reference; true or magnetic. Default setting is TRUE.

BOTTOM LOST: Turns on or off the bottom loss warning. “ALARM” sounds the alarm if the bottom signal is not detected. Default setting is “ALARM” (alarm is enabled).

GPS ALARM: The audible alarm may be released when the position-fixing mode is switched from DGPS to GPS and vice versa. Default setting is “ALARM” (alarm is enabled). Choose “OFF” if you do not need to be alerted with the audible alarm when the position-fixing mode is switched.

INTERFACE: Selects I/O signal format between the FE-700 and external equipment; IEC format “1:95” (1995 version) or “1:98” (1998 version), or NMEA format. Default setting is IEC “1:98”.

When selecting the “1:98”, DPT has max. range in use (See page 24).

 

Output

Input

IEC 61162-1

DPT

RMA, RMC

 

 

GLL, VTG

 

 

ZDA, GGA

NMEA 0183

DBT (Ver.1.5)

RMA, RMC

 

DBS (Ver.1.5)

GLL, VTG

 

DPT (Ver.2.0)

ZDA, GGA

ALARM SOUND: Selects audio alarm sound among 1, 2 or 3. Default setting is 1.

1:Continuous sound

2:Intermittent sound; 0.5 s on and 0.5 s off.

3:Intermittent sound; 1 s on and 1 s off.

OS DATA: Selects own ship data display mode; DATA 1 or DATA 2. DATA1 is the default setting. If a navigation device is not connected to the FE-700, select DATA 2.

LANGUAGE: Currently English is only available.

3.3 System Menu 2

TIME ADJUST: Selects internal clock or external clock (UTC clock). Default setting is INTERNAL. For INTERNAL, set current day, month, year, hour, minute and second with [+], [-], [▼] or [▲] key. The setting clock appears and it counts upward.

SYSTEM MENU 2

MENU SELECT

 

1

2

3

 

TIME ADJUST

 

INTERNAL

EXTERNAL

DAY

1

 

 

 

 

MONTH

JAN

 

 

 

YEAR

2001

 

(2100)

HOUR

0

 

 

(023)

MINUTE

0

 

 

(059)

SECOND

0

 

 

(059)

01 JAN 2001 00:00:00

▼▲: To select item

- +: To set option

Select other mode to exit.

If EXTERNAL is selected, the screen changes as follows.

SYSTEM MENU 2

MENU SELECT

1

2 3

 

 

TIME ADJUST

 

INTERNAL

EXTERNAL

TIME DIFFERENCE

 

AUTO

 

MANUAL

0:22:40

▼▲: To select item

-+: To set option Select other mode to exit.

TIME DIFFERENCE: Selects auto (UTC) or manual. Auto uses the time difference in ZDA (IEC 61162-1). In manual, it is necessary to enter the time difference in hours and minutes.

12

Image 22
Contents Navigational Echo Sounder Pub. No. OME-23660 Yosh FE-700 DECSafety Instructions Record of Modifications in this OPERATOR’S Manual MENU3Contents Foreword FeaturesWord to FE-700 Owners System Configuration Display UnitSpecifications of Navigational Echo Sounder E2366S01QGLL L/L IPX5GGA L/L Power Supply Operation Control DescriptionIndications, Markers Turning On/Off Tone and Brilliance ROM OK Dram OK Sram OK Battery OKPanel Dimmer DBS mode Display ModeNAV mode History modeLogbook mode OS Data modeMenu display Help displayGain Control How to enable/disable automatic operationRange Scale Automatic OperationAcknowledging the alarm Shallow Depth AlarmActivating/deactivating the alarm DraftSuppressing Low Level Noise Menu OperationMenu Overview Suppressing InterferenceTrend Picture AdvanceInterval System Menu System MenuOutput Input System Menu Demonstration Display Echo Quality SettingTransducer Setting DEMONSTRATION. DemonstrationTVG Level Bottom LevelEcho Offset Adjusting Contrast Operation of Digital Depth Indicator FE-720 OptionAdjusting panel dimmer Basic OperationSelecting language Menu OperationDimmer control Selecting the unit of depth measurementDiagnosis Factory SettingAlarm OFFCleaning the Display Unit MAINTENANCE, TroubleshootingTransducer Maintenance Replacing the Fuse, BatteryTroubleshooting Symptom Probable Causes RemedyBlack Diagnostic TestTest Pattern WhiteDON’T Turn Power OFF Until Completed Memory Clear Clearing the MemoryExtension Mode Menu TreeRMA, RMC, GLL, GGA, VTG, ZDA Digital Interface IEC 61162-1 EditionO Sentences DBT, DPT, DBS NmeaSchematic Diagrams NAV in port listenerDBS Depth below surface Sentence DescriptionDPT Depth DBT Depth below transducerGLL Geographic position latitude/longitude GGA Global positioning system GPS fix data RMA Recommended minimum specific LORAN-C data RMC Recommended specific GPS/TRANSIT data VTG- Course over ground and ground speed ZDA Time and dateParts LOCATION, Parts List Furuno Code No