Configuration
Setting up a CLI Connection
Setting up a CLI Connection
A CLI connection will require the LAN or WAN IP address of the unit. Note: If the WAN IP address is used, the remote admin WAN access must be enabled with the following command sequence:
Command | Description |
Username: admin | Log into the system (username and password). |
Password: ******** |
|
Adit 3104> enable | Enter the Privileged mode. |
Password: ******** | Enter password for the Privileged mode. |
#configure terminal | Enter the Configuration mode. |
(config)# | Enable remote web admin. |
|
NOTE: For Adit 3104 CLI commands see the Adit 3000 CLI Reference Manual. This is a separate document and can be found on the CD that is provided with the product, or on the Carrier Access customer website.
To connect with CLI, set up the connection:
If connecting via the Ethernet
Note: To display the current IP address of the unit, use the ifconfig command. If connecting via
Bits per second: 115200 | Data bits: 8 |
Parity: None | Stop bits: 1 |
Flow control: None |
|
Set your Terminal Emulation to: VT100 |
|
NOTE: When using Tera Term (Telnet program) TCP/IP, CLI commands will not be recognized until the following setup is completed.
In Tera Term go to Setup/Terminal
Set the
Adit 3104 - Release 1.6 |