Read Verification by Symbology
To set the minimum read requirement for a desired symbology:
1. Scan the SET label.
2. Scan one symbology label below to select the symbology to be verified.
3. Scan the label on the following page representing the amount of times you wish a bar code label of that symbology type to be read before transmission to the host.
4. Repeat steps one through three above until read verification has been selected for all symbologies you desire to be verified.
5. Scan the END label.
SET
READ VERIFICATION SYMBOLOGY TYPE
VERIFY UPC-A -------------------
VERIFY UPC-E -------------------
VERIFY EAN-8 --------------------
VERIFY EAN-13 ------------------
VERIFY INSTORE LABEL1
VERIFY CODE 39 ------------------
1Instore labels are
Programming Guide | 83 |