Datalogic Scanning GM4100 manual Technical Specifications, Description

Page 38

Technical Specifications

Technical Specifications

The following table contains Physical and Performance Charac- teristics, User Environment and Regulatory information.

Item

Description

 

 

 

 

Physical Characteristics

 

 

 

Color

White/Gray

Black/Gray

 

 

 

 

Height 7.1”/181 mm

Dimensions

Length 3.9”/100 mm

 

Width 2.8”/71 mm

 

 

 

Approximately

Weight (without cable)

8.7 ounces/246 g (reader with display)

 

8.7 ounces/246 g (base charger)

 

 

Electrical Characteristics

 

 

 

Battery Type

Li-Ion battery pack

 

 

Charge time for full charge

4 hours with external power supply adaptera

max 22h hours with Host power

from full discharge

(in this case no supply adapter is needed)a

 

Operating autonomy

50,000 reads

(continuous reading)

(typical)

 

 

Cradle consumption

Volt 4.75-14 VDC; Power <8Wb;

and DC input supply range

Imax 500mA when in host/bus powered modeb.

Performance Characteristics

 

 

Light Source

LEDs

 

 

Roll (Tilt) Tolerance

± 35° from normal

 

 

Pitch Tolerance

± 65°

 

 

Skew (Yaw) Tolerance

± 65°

 

 

Field of View

10” (25.4cm) wide at 12.5” (31.8cm) from the reader

 

 

 

3 mil – 2.9” to 4.7” (7.5cm to 12cm)

Depth of Field (Typical)c

13 mild – 1.2” to 23.6” (3cm to 60cm)

 

20 mil – 1.2” to 31.5” (3cm to 80cm)

 

 

Minimum Element Width

3 mil

 

 

34

Gryphon™ I GM4100

Image 38
Contents Gryphon I GM4100 Datalogic Scanning, Inc Table of Contents Page Statement of Agency Compliance FCC Class B Compliance StatementCanadian Notice Gryphon Product Series END User License Agreement Intellectual Property Limitation Of Liability Software Product Policy Customers Under Software SupportSetting Up the Reader Battery SafetySerious injury Do not replace the battery pack when the device is turned on Install the Batteries ConnectorInsert the cover in the handle and screw it back into place Configuring the Base Station Changing the Base Station PositionTab Connecting the Base Station Securing the DC Power Cord OptionalOptions for routing the DC cord Connecting to the Host Stand Alone Layouts System and Network LayoutsRF Devices Multiple Reader Layout Using the BC40xx Radio Base Base LEDsDisplay Using the Programming BarcodesProgramming Configure Other Settings Select the Interface TypeConfiguring the Interface Interface SelectionIBM Keyboard Keyboard Wand Emulation Keyboard Interface Country ModeStandard Factory Settings Scancode TablesCountry Mode Country Mode Country Mode Country Mode Caps Lock State Numlock Technical Specifications Description15% minimum reflectance Regulatory LED and Beeper Indications LED BeeperReader Error Codes NumberBase Station Indications Indication LedsRegulatory Information Power SupplyErgonomic Recommendations Imager Labeling Weee Statement Warranty ExclusionsWarranty Quick Reference Guide Warranty Declaration of Conformity Italy