Datalogic Scanning QS2500 manual Data Checksum

Page 48

Code 128

Read: Format:

Data Digits (Variable)

Checksum (Optional)

Checksum Verification: The checksum is presented as the sum mod 103 of all data digits.

Checksum Transmission: When this option is enabled, the QS2500 will transmit the checksum.

Maximum/Minimum Code Length: Same as Code 39. See page 35.

Truncate Leading/Ending: Same as UPC-A. See page 27.

Code ID Setting: Same as UPC-A. See page 27.

Insertion Group Selection: Same as UPC-A. See page 27.

Format: The Code 128 data string can be translated to UCC/EAN-128 format if it starts with “FNC1”. The first “FNC1” will be translated to “]C1”, and the second “FNC1” to a concatenation code “<GS>(1Dhex)”.

]C1

Data

<GS>

Data

Checksum

Append: When the function is enabled, it won't show the data immedi- ately if scanner read the barcode includes FNC2 code. It will show all data until it read a barcode, which doesn't have FNC2 code.

]C2

Data

<GS>

Data

Checksum

Concatenation Code: This feature is only used for UCC/EAN-128. The Concatenation Code is the separator character, default is <GS> (1Dhex), inserted between characters when label data is concatenated and treated as a single entry.

For example:

UCC/EAN-128 Structure:

<start> <FNC1> <Label data 1> <FNC1> <Label data 2> <CK> <stop>

44

QS2500

Image 48
Contents QuickScan QS2500 Datalogic Scanning, Inc Table of Contents Appendix E Alphanumeric Characters Installation Keyboard WedgeWand Emulation RS-232USB Programming the QS2500 Scan the alphanumeric characters located in Appendix EResetting the QS2500 InterfacesOption Bar Code QS2500 Option Option Alphanumeric Default Option Bar Code Alphanumeric RS-232 Advanced Features Response Delay IBM Interface 46XX/USB IBM Options IBM 46xx Code 39 ConversionIBM Host Commands Scanning Mode Same Bar Code Delay TimeScanning Standby DurationDouble Confirm Option Disable Inverted Image Scan Enable Beep/Tone/LED Settings Beep & LED after decode Label Editing includes Prefix/Suffix Option Bar Code Alphanumeric Insert Data Group Disable ID Transmission Enable Symbology Settings UPC-AUCC/EAN UPC-E Truncate Ending FfH Ascii code EAN-13 Disable Checksum Transmission Enable EAN-8 Ascii Code Use Global Min Minimum Code Length Interleaved 2 Use Global Min Code Length Industrial 2 Matrix 2 Ff hexB Codabar ABCD/ABCD Data Checksum UCC/EAN-128 Disable Append Enable Ff hex Ascii Enable two digits Data Digits Variable Checksum1 Optional MSI/Plessey Mini UK/Plessey Alphanumeric Telepen Standard 2 Disable Enable Code 16K Ff hex Italian PharmaCode RSS Expanded RSS Limited RSS-14 Appendix Default Settings Checksum Code Code TypeAppendix B Bar Code Samples EAN-8Matrix 2 Codabar Code Italian PharmaCode RSS Expanded RSS Limited RSS-14 Appendix C Ascii Codes Example Ascii a = Appendix D Parameter Setting List Start Program Standard Parameter Setting ListAppendix E Alphanumeric Characters QS2500 Page Italy