Juniper Networks IDP 800, IDP250, IDP8200 manual Connecting Power, RU Device IDP 75 Midmount Bracket

Page 34

IDP 75, 250, 800, and 8200 Installation Guide

Figure 11: 1 RU Device (IDP 75) Midmount Bracket

2.Place the chassis into position between rack posts in the equipment rack and align the rack mounting bracket holes with the rack post holes.

CAUTION: Be sure to leave at least two inches of clearance on the sides of each chassis for the cooling air inlet and exhaust ports.

3.Attach the rack-mounting brackets on each chassis to the rack with the appropriate rack screws.

4.(For 2 RU devices only) Attach the other two midmount brackets to the chassis and the back of the rack to hold the device securely in place.

Connecting Power

NOTE: Power is provided to the IDP sensor using 90/264 VAC from your facility.

To connect power to your sensor:

1.Connect the provided power cable to the receptacle on the power supply at the rear of each chassis.

2.Connect the other end of the power cable to the electrical outlet.

3.(For IDP 800 and 8200 sensors only) Connect the second power cable to the receptacle on the second power supply. This step is optional for the IDP 8200 sensor.

4.(For IDP 800 and 8200 sensors only) Connect the other end of the second power cable to the electrical outlet. This step is optional for the IDP 8200 sensor.

NOTE: If you have two power supplies and do not connect both of them, the PS FAIL warning light illuminates and the sensor emits a warning tone when it is turned on.

20„ Connecting Power

Image 34
Contents Releases 4.1r2a April Copyright Notice Table of Contents Chapter Adding the Sensor to NSM Index Page Sniffer Mode Passive List of FiguresPage List of Tables Page Conventions About This GuideAudience Icon Meaning DescriptionDocumentation Web Access for DocumentationRequesting Technical Support Self-Help Online Tools and Resources Opening a Case with JtacPage Planning an Installation Installation RoadmapIDP Sensor Placement IDP Configuration BasicsIDP Sensor Deployment Mode Sniffer Mode Passive Advantages and Disadvantages of Sniffer Mode Passive Transparent Mode Inline ActiveNetScreen-Security Manager Page Hardware Overview IDP SensorsIDP 250 Sensor IDP 75 SensorIDP 800 Sensor IDP 8200 Sensor IDP 800 Front PanelConfigurable NIC States Traffic Ports Forwarding InterfacesNIC Bypass State Settings Modes Availability DescriptionNormal State NIC State OptionsExternal Bypass Unit State NIC Bypass and Cable ChoicesNICs Off State Console Serial Port Power SuppliesManagement Ports Management PortSystem Status LEDs IDP Sensor Power SuppliesIDP Sensor LEDs Management and High Availability Port LEDsTraffic Port LEDs Hard Drive LEDs on Front PanelPower Supply LED Definitions Back Panel LED Description Power Supply LEDs on Back PanelHard Drive LED Definitions Front Panel LED Description Installing the Sensor General Installation GuidelinesRack Mounting the IDP Sensor Mounting Using Device Rack RailsRequired Tools Mounting Using Midmount Brackets Rail with Hinged Rear BracketConnecting Power RU Device IDP 75 Midmount BracketSimple Configuration Configuring the IDP SensorInitial Configuration Options Simple Configuration SettingsConnecting to the Sensor Simple Configuration ValuesAdvanced Configuration Using the Console Serial Port to Configure the SensorType an IP address and press Enter Following text appears Using the Management Port to Configure the Sensor Connecting Directly Using the Management PortConnecting Remotely Using the Management Port Simple or Advanced Configuration Using the Management PortQuickStart Simple Configuration ACM Advanced ConfigurationManager Administrator’s Guide Connecting the High Availability Port Connecting Forwarding InterfacesVerifying Traffic Flow Adding the Sensor to NSM Adding Your Sensor to NSMSelect Device is Reachable default Add Device Wizard Connection Settings Type ssh-keygen -l -f sshhostdsakey and press Enter Checking the Status of Your Sensor Add Device Wizard Importing the DevicePage Updating Software on the Sensor Updating IDP Sensor Software Using NSM Firmware ManagerLoading a Sensor Image into NSM Upgrading Sensor Software Updating IDP Sensor Software Without NSMReimaging the IDP Sensor Page Remove a Power Supply Replacing a Power Supply IDP 800, and 8200 OnlyServicing the Device Replacing a Hard Drive IDP 800 and 8200 Only Install a Power SupplyRemove a Hard Drive Install a Hard Drive Hard Drive Latch in Closed PositionPage Bridge Mode Advanced ConfigurationAdvanced Deployment Modes Bridge Mode Advantages and Disadvantages of Bridge ModeRouter Mode Advantages and Disadvantages of Router ModeAdvantages and Disadvantages of Proxy-ARP Mode Proxy-ARP ModeIDP High Availability Deployment Modes Specifications AC Power Specifications Nominal Value Acceptable Range IDP 75 Technical SpecificationsPhysical Specifications Value Power Cord Specifications CountryEnvironmental Specifications IDP 250 Technical SpecificationsSpecification Value IDP 800 Technical Specifications IDP 8200 Technical Specifications EMI Compliance Safety ComplianceImmunity Index ACMIDP 75, 250, 800, and 8200 Installation Guide 54 „ Index
Related manuals
Manual 84 pages 43.14 Kb

IDP75, IDP 800, IDP8200, IDP250 specifications

Juniper Networks IDP250 is a robust Intrusion Detection and Prevention system designed to provide comprehensive security for enterprise networks. This device plays a crucial role in safeguarding sensitive data and maintaining the integrity of network infrastructures against the ever-evolving landscape of cyber threats.

One of the main features of the IDP250 is its advanced threat detection capabilities. The system utilizes deep packet inspection technologies, allowing it to analyze network traffic in real-time. This feature ensures that malicious activities are identified and addressed before they can compromise the network's security. Additionally, the IDP250 is designed to recognize not only known threats but also emerging threats by leveraging heuristic and signature-based detection techniques.

Another significant characteristic of the IDP250 is its ability to integrate seamlessly into existing network infrastructures. It supports a variety of deployment scenarios, whether in-line, out-of-band, or as a dedicated network appliance. This flexibility enables organizations to adapt the IDP250 to their unique needs without extensive reconfiguration of their network topology.

The IDP250 is powered by Juniper’s proprietary software platform, which provides a user-friendly interface for monitoring and managing security incidents. The intuitive dashboard offers insights into network traffic patterns, security alerts, and overall system performance. Organizations can configure custom alerts and reporting features, thereby streamlining incident response and enabling proactive management of potential vulnerabilities.

Scalability is another important aspect of the IDP250. Designed to accommodate growing network demands, the device supports high throughput and can effectively handle large amounts of simultaneous traffic. This scalability ensures that as businesses expand, their security solutions remain robust and effective.

In terms of compatibility, the IDP250 supports various networking protocols and can be integrated with other security solutions, such as firewalls and Security Incident and Event Management (SIEM) systems. This interoperability enables organizations to build a multi-layered security architecture that enhances overall protection.

Finally, the IDP250 comes equipped with comprehensive logging and reporting features. Detailed logs enable security analysts to conduct thorough investigations of security incidents, thus facilitating compliance with industry regulations and standards.

In conclusion, Juniper Networks IDP250 stands out as a powerful and versatile Intrusion Detection and Prevention system. With its advanced threat detection capabilities, seamless integration, scalability, and comprehensive logging features, it is an essential tool for organizations looking to bolster their network security defenses.