Copying Parameters Between Switches:
The 232BSS4 setup software can save configuration data to a file for copying of parameters. Any unit’s setup can be copied by first reading the data from one switch, then saving to another.
Step 1: | Run the setup software. |
Step 2: | Select serial (COM) port to be used for programming. |
Step 3: | Select Single Unit operation. If the configuration to be used |
| is already saved to a file, skip to Step 8. |
Step 4: | Connect the switch to be copied to the serial (COM) port of |
| the PC. Install the setup jumper. Apply power to the |
| 232BSS4. |
Step 5: | Click Next. |
Step 6: | Select Save As from the File menu. Save the configuration to |
| disk. |
Step 7: | Disconnect the first 232BSS4 from the COM port. |
Step 8: | Connect the destination switch to the serial (COM) port of |
| the PC. Install the setup jumper. Apply power to the |
| 232BSS4. |
Step 9: | Select File/Load File and load the saved configuration. |
Step 10: | Click Save Changes |
Once the configuration file has been loaded, any number of switches can be set to the same parameters by connecting and configuring each in turn.
Default Parameters:
When shipped, the 232BSS4 comes set up for the following parameters:
Auto Select mode OFF
DTR NOT required to accept commands
Char1 = ESC (Decimal 27)
Char2 = STX (Decimal 2)
Char3 = “0” (Not Used)
Port Time = 1,000 mS (Not Used)
Inactivity Time = 500 mS (Not Used)
All ports 9600 Baud
All ports 8 Data Bits
All ports No Parity
All ports No Hardware Handshake required
Ports
Port A selected to Transmit & Receive on
Documentation Number 232BSS42907 Manual | 29 |
B&B Electronics Mfg Co Inc – 707 Dayton Rd - PO Box 1040 - Ottawa IL 61350 - Ph
B&B Electronics Ltd – Westlink Commercial Park – Oranmore, Galway, Ireland – Ph +353