Specifications
Model: | 232BSS4 |
Interface: | |
Data Format: | 7 or 8 data bits, even, odd, or no parity |
| (Master does not support 7 data bits with no |
| parity) |
Data Rate: | 1 stop bit (fixed) |
1200 to 115.2 kbps | |
Flow Control: | Hardware(RTS/CTS) or None |
Power Requirements: | +10 to +15 VDC @ 60 mA max. |
Power Connector: | 2.5 mm phone jack (+ tip) |
Recommended Supply: | B&B Model 232PS (Sold separately) |
Operating Temperature:0º to 70º C | |
Data Connectors: | Master DB25 female (DCE) |
Dimensions: | Slaves DB9 male x 4 (DTE) |
7.5 x 4.6 x 1.2 in. (19.0 x 11.7 x 3.0 cm) | |
Setup Software: | PC compatible, |
Supplied Accessories: | Windows 95/98/NT/2000/XP/Vista |
CDROM with Setup Program | |
| Instruction Manual |
Default Parameters
When shipped, the 232BSS4 comes set up for the following parameters:
Auto Select mode OFF
DTR NOT required to accept commands
THREE character command
Char1 = ESC (Decimal 27)
Char2 = STX (Decimal 2)
Char3 = “0” (Not Used)
Port Time = 1,000mS (not used)
Inactivity Time = 500mS (not used)
All ports 9600 Baud
All ports 8 Data Bits
All ports No Parity
All ports No Hardware Handshake required
Ports
Port A selected to Transmit & Receive on
Refer to the following sections of the manual for what each of these parameters means and how they can be changed.
2 | Documentation Number |
B&B Electronics Mfg Co Inc – 707 Dayton Rd - PO Box 1040 - Ottawa IL 61350 - Ph