Chapter 2: OPERATION
Symbols and Conventions
Throughout this chapter of the manual, the following symbols and conventions will be used to clarify what type of data we are addressing.
•Items enclosed in {brackets} will denote one byte.
•A character in “quotes” will normally denote a printable ASCII character. A byte described in ALL CAPS is the ASCII description of a
•Items in italics are optional items only used in certain configurations. The instances when these items are required will be explained in the text.
LED Indicators
The 232BSS4 has five LED indicators. The first, labeled “+12 VDC POWER” indicates that power is applied to the switch. The other four, labeled “PORT A” to “PORT D” indicate which Slave port is currently selected to transmit to the Master.
In Smart Switch Only mode, the port LEDs indicate which port was selected through the Select Port command. In Auto Select mode, the port LEDs indicate which port is currently sending to the Master. No indication is provided to display which Slave port is currently receiving from the Master.
Documentation Number | 5 |
&B Electronics Mfg Co Inc – 707 Dayton Rd - PO Box 1040 - Ottawa IL 61350 - Ph