B&B Electronics EIR505-XX manual Wiring the Fault Alarm Contact, 1A@24V

Page 20

Wiring the Fault Alarm Contact

The fault alarm contact are located in the middle of terminal block connector as shown below. Insert the wires and set the Dipswitch to “ON”. When a power source fails or a link fault occurs, it will be detected and cause an open circuit. The following figure shows an application example for the fault alarm contact.

1A@24V

Insert the wires into the fault alarm contact

[NOTE] The wire range of terminal block is from 12~ +24 AWG.

Fault Alarm Contact

The open circuit will form when the power failure or port link failure.

24V DC Buzzer

 

 

24V Battery

 

 

 

 

 

 

 

 

The fault alarm device will send a warning signal to warn the user, ex: alarm sound or flash light.

10

Manual Documentation Number: EIR505-xx_5107m

 

 

B&B Electronics Mfg Co Inc – 707 Dayton Rd - PO Box 1040 - Ottawa IL 61350 - Ph 815-433-5100 - Fax

815-433-5104www.bb-elec.com

 

B&B Electronics – Westlink Commercial Park – Oranmore, Galway, Ireland – Ph +353 91-792444

– Fax +353 91-792445www.bb-europe.com

Image 20
Contents Product Description Page Five Port Managed Industrial Ethernet Switches Hardware Version Firmware VersionKernel Version FCC Warning CE Mark WarningContent Wall Mount Plate Mounting Igmp Troubles shooting Technical Specification Page Features IntroductionPackage Contents Physical Dimension Reset ButtonHardware Description Front PanelBottom View DIP-switchDIP Switch No Status Description LED Indicators Status Meaning Power Green Switch is onPorts Pin MDI-X Signal Name MDI Signal Name RJ-45 Pin Assignments Pin NumberCabling „ Fiber PortWiring the Power Inputs Wiring the Fault Alarm Contact 1A@24VMounting Installation DIN-Rail MountingManual Documentation Number EIR505-xx5107m Panel Mounting Hardware Installation Network Application Ring ApplicationCoupling Ring Application Dual Homing Application Preparing for Web Management Web-Based ManagementAbout Web-based Management Function Menu Bar System LoginPanel Figure Display Configuration Display Screen Port status Single Port InformationPort Statistics Port Control Port Control interfaceSwitch Settings Port Mirroring Port Mirroring interfaceVlan configuration Port-based VlanVlan Port Base interface 802.1Q Vlan „ Basic Click Next to bring up the configuration interface To reset to the default values, click IP Address Sntp Configuration Local Time Zone Conversion from UTC Time at 1200 UTCManual Documentation Number EIR505-xx5107m GST IP Security Rstp Configuration System ConfigurationRSTP- System Configuration Interface Per Port Configuration Ring Manual Documentation Number EIR505-xx5107m QoS Configuration Manual Documentation Number EIR505-xx5107m Igmp Message Description QueryReport Leave GroupSecurity Manager Configuration BackupTftp Restore Configuration Tftp Server IP Address Enter the Tftp server IP Tftp Update FirmwareTftp Backup Configuration Factory Default System RebootSave Configuration Rate ControlQos and Rate control cannot exist at the same Trouble shooting Technical Specification SC Single mode 9/125um~10/125um Power SupplyClass of service Network CableQuality of service RingSpanning tree Management IPInstall AlarmFirmware update Temperature Case DimensionSafety Stability testing