Blade ICE BMD00178 manual VMready

Page 15

BLADEOS 6.3 Application Guide

VMready

The switch’s VMready software makes it virtualization aware. Servers that run hypervisor software with multiple instances of one or more operating systems can present each as an independent virtual machine (VM) with its own applications. With VMready, the GbESM automatically discovers virtual machines (VMs), virtual switches, and VM NICs (collectively known as virtual entities or VEs), and can distinguish between regular VMs, Service Console Interfaces, and Management Interfaces. BLADEOS 6.3 supports up to 1024 VEs.

VEs may be placed into VM groups on the switch to define communication boundaries: VEs in a given VM group are permitted to communicate with each other, while VEs in different groups are not. VM groups also allow the configuration of group-level settings, such as virtualization policies and ACLs.

The administrator can pre-provision VEs by adding the MAC addresses of potential VEs to a VM group. When a VE with a pre-provisioned MAC address becomes connected to the switch, the switch will automatically apply the appropriate group membership configuration.

The GbESM with VMready detects the migration of VEs across different hypervisors. As VEs move, the GbESM NMotionfeature automatically moves the appropriate network configuration as well. NMotion gives the switch the ability to maintain assigned group membership and associated policies (such as VLAN Maps and VM policy bandwidth control) when a VE moves to a different port on the switch.

VMready also works with VMware’s Virtual Center (vCenter) for advanced VE management. By connecting with the vCenter, the switch can obtain information about distant VEs, push VM configuration profiles to the VEs in distributed VM groups, and enhance VE migration.

VMready is configured from the Virtualization menu, available with the following CLI command:

#/cfg/virt

BMD00178, April 2010

15

Image 15
Contents Release Notes Bladeos 6.3 Application Guide Release Notes 10Gb Uplink ESM Faceplate Hardware SupportRecommended SFP+ transceiver Loading New Software to Your Switch Updating the Switch Software ImageUsing the Bladeos CLI Using the Iscli Using the BBI Recovering from a Failed Upgrade Using the Boot Management Menu## Switch baudrate to 115200 bps and press Enter ## Switch baudrate to 9600 bps and press ESC Stacking New and Updated FeaturesStacking Limitations VMready Vlan Maps OSPFv3 statistics menu OSPFv3Port Trunk Hashing Enhancements Active MultiPath ProtocolManagement Interface Connection SM IPv4 and IPv4 Configuration ExtensionsIgmp Group Capacity Management Module Supplemental InformationManagement Module/GbESM Connectivity Trunk Group Configuration Tips Secure Management NetworkSecure Shell SSH FTP/TFTP Directory Path Spanning Tree Configuration TipsSyslog Configuration Tip Internal Port AutonegotiationSTP Edge and Link Command ReplacementsBpdu Guard Igmp Relay Known IssuesSoftware Upgrade Issues Access Control ListsInteroperability with Older Hubs Link Aggregation Control ProtocolLinking at 10/100Mb Radius with SSHv2 Static MrouterQoS Metering QoS and TrunkingBrowser Based Interface Strong Password ExpirationTrunk and Link Loop Trunk TrafficDaylight Saving Time VCenter SynchronizationBladeos 6.3 Application Guide