Blade ICE BMD00178 Static Mrouter, QoS Metering, QoS and Trunking, Radius with SSHv2, RIP MIBs

Page 29

BLADEOS 6.3 Application Guide

Static Mrouter

If a port has a static multicast router (Mrouter) configured, and you move the port to a different VLAN, the static Mrouter appears in the /info/l3/igmp/mrouter/dump output for the original VLAN.

Solution: When you move the port to a new VLAN, remove the static Mrouter from the port, and add it again.

QoS Metering

Traffic may exceed the configured maximum burst size of the ACL meter

(/cfg/port <x>/aclqos/meter/mbsize) by one packet, with that packet remaining In-Profile. Once the ACL meter has been exceeded, additional burst packets fall Out-of-Profile.

QoS and Trunking

When you assign an ACL (or ACL Group) to one port in a trunk, BLADEOS does not automatically assign the ACL to other ports in the trunk, and it does not prompt you to assign the ACL to other ports in the trunk.

Solution: Manually assign each ACL or ACL Group to all ports in a trunk.

RADIUS with SSHv2

With RADIUS turned on, users might see a duplicate login prompt for SSHv2 clients, if the RADIUS server is too slow to respond or if the RADIUS server is not available. In this case, users must re-type the username and password to login.

RIP MIBs

Due to backward-compatibility issues, two Routing Information Protocol (RIP) MIBs are available in BLADEOS: ripCfg and rip2Cfg. Use the rip2Cfg MIB to configure RIPv1 and RIPv2 through SNMP.

BLADEOS does not support the standard RIPv2 MIB as described in RFC 1724. Use the rip2Cfg MIB to configure RIPv1 and RIPv2 through SNMP.

BMD00178, April 2010

29

Image 29
Contents Release Notes Bladeos 6.3 Application Guide Release Notes 10Gb Uplink ESM Faceplate Hardware SupportRecommended SFP+ transceiver Loading New Software to Your Switch Updating the Switch Software ImageUsing the Bladeos CLI Using the Iscli Using the BBI Recovering from a Failed Upgrade Using the Boot Management Menu## Switch baudrate to 115200 bps and press Enter ## Switch baudrate to 9600 bps and press ESC Stacking New and Updated FeaturesStacking Limitations VMready Vlan Maps OSPFv3 statistics menu OSPFv3Port Trunk Hashing Enhancements Active MultiPath ProtocolManagement Interface Connection SM IPv4 and IPv4 Configuration ExtensionsIgmp Group Capacity Management Module Supplemental InformationManagement Module/GbESM Connectivity Secure Shell SSH Trunk Group Configuration TipsSecure Management Network Syslog Configuration Tip Spanning Tree Configuration TipsInternal Port Autonegotiation FTP/TFTP Directory PathSTP Edge and Link Command Replacements Bpdu Guard Software Upgrade Issues Known IssuesAccess Control Lists Igmp RelayLinking at 10/100Mb Interoperability with Older HubsLink Aggregation Control Protocol QoS Metering Static MrouterQoS and Trunking Radius with SSHv2Trunk and Link Loop Strong Password ExpirationTrunk Traffic Browser Based InterfaceDaylight Saving Time VCenter SynchronizationBladeos 6.3 Application Guide