Asante Technologies 10BaseT, 10BaseFL manual Switches for 10Base2 MAU, Termination

Page 23

Switches for 10Base2 MAU

The default settings are identified below:

Termination disabled (1, switch UP)

HBE disabled

(1, switch UP)

Termination

The Mini 10Base2 MAU has a built-in 50ohm termination resistor. This is useful if the user does not have a terminator. If enabled the switch is in the “Down” (0) position and the 50 ohm termination is connected across the BNC.

HBE

The HBE can be disabled on the Mini 10Base2 MAU by setting the DIP switch to the “UP” (1) position. This is the default setting.

Mini MAU

Page 20

Image 23
Contents Mini MAU Copyright Notice Asanté Warranty Disclaimer Introduction Technical Support Hours Asking for assistanceProduct Overview Asanté Mini MAUs Summary of Mini MAU Features Mini MAU Media and Connectors Mini MAU for 10BaseT Twisted-pair cable 10BaseT with Mini MAU Installation Mini MAUMini MAU for Thin Ethernet MAU Thin cable 10Base2 with MiniMini MAU for Fiber Fiber Mini 10BaseT MAU LED Display LEDs and Switches for the MiniHBE Switch Switches for 10BaseT MAUPolarity Correction Link Integrity Enabled Test SwitchMini MAU Fiber to hub Mini 10BaseFL MAU Loopback Test Switch Switches for 10Base-F MAUMini MAU Thin Ethernet to Macintosh HBE on Mini 10Base2 MAUTermination Switches for 10Base2 MAUInstalling a Mini MAU for the AsantéHub Mini MAU Environmental PowerDimensions Specifications Mini MAU