IDEAL 4107; IDEAL 4109
2.2 Power supply
The name plate is located at the rear of the machine.
- Data stated on the name plate - Voltage “ V “,
- Frequency “Hz”,
- Power consumption “A”
must correspond to the values of the power supply unit.
- Earth wire must be available.
- Connect the machine to the mains.
2.3 Checking rotating direction
Operate the machine for a short time as described under 3. “Operation“..
- The material is transported to the shredding mechanism by a conveyor belt.
Warning!
Switch off the machine immediately at the main switch if the conveyor belt runs in the opposite direction.
When the conveyor belt runs in the opposite direction:
The machine is wired according to the IEC standardized rotary field. When changing the rotary direction we recommend that this is performed by an experienced specialist. The rotary direction is changed by exchanging the “L1“ and “L2“ connections in the plug.
Danger!
Incorrect exchanging of connections may endanger the operator. If in doubt, this work should be performed by an electrical specialist.
6