•Convergence Rough Adjustment
1.Enter the crosshatch signal.
2.Recheck focus and readjust when focus was worse.
3.Adjust roughly H. STAT and V. STAT convergence by 4 pole magnet.
4.Adjust roughly HMC and VMC by 6 pole magnet.
•Convergence Adjustment
1.Open H and V Stat by 4 pole magnet.
2.Adjust 6 pole magnet perform HMC and VMC.
3.Adjust 4 pole magnet close both Stat of R.G.B just overlap each other Horizontal and Vertical.
4.Adjust TLH for side MC by TLH magnet when R or B is in the opposite direction.
5.Adjust XCV to correct Vertical cross MC.
6.Adjust XBV to correct Vertical bow MC.
7.Adjust TLV to corect Vertical tilt MC.
8.Adjust YCH to correct top and bottom Horizontal cross MC.
9.Adjust YBH to correct top and bottom Horizontal bow MC.
10.Using permalloys to correct MC of the cornters.
11.Check convergence for whole screen. If necessary, perform step from
12.Paint lock 4 pole magnet, 6 poles magnets, XBV reactor XCV corrector and TLH corrector handle.
6Pole Mg | Purity Mg. | TLH |
|
| XCV |
| YCH | YV |
| DY CRT |
|
4Pole Mg
•Convergence Specification
B |
|
| |
MODE | All mode | ||
| |||
A |
|
| |
A | 0.30 mm | ||
| |||
|
|
| |
| B | 0.35 mm | |
|
|
|
•White Balance Adjustment Specification
(1) | 9300K |
| (2) 6500K |
|
| x = 0.283 ± | 0.01 | x = 0.313 ± | 0.01 |
| y = 0.298 ± | 0.01 | y = 0.329 ± | 0.01 |
(2)5000K
x= 0.346 ± 0.01
y= 0.359 ± 0.01
•Vertical and Horizontal Position and Size Specification
A
b
MODE All mode
BA 312 mm
a
B | 234 mm |
a 1.5 mm b 1.5 mm
•Focus adjustment
Adjust the focus volume 1 and 2 for the optimum focus.
XCVYCH
B
RR B
TLVTLH
R | R |
| B | B R |
| ||||
B |
|
|
|
|
B |
|
|
|
|
R |
|
|
|
|
XBV
R
B
YBH
R B
Focus 1
(V)
Focus 2
(H)
FBT