Dell E21S001, R820 owner manual Troubleshooting a Serial I/O Device, Troubleshooting a NIC

Page 110

7.Power down all attached USB devices and disconnect them from the system.

8.Reboot the system and, if your keyboard is functioning, enter the System Setup. Verify that all USB ports are enabled on the Integrated Devices screen, in the System Setup options.

If your keyboard is not functioning, you can also use remote access. If the system is not accessible, reset the NVRAM_CLR jumper inside your system and restore the BIOS to the default settings.

9.Reconnect and power on each USB device one at a time.

10.If a device causes the same problem, power down the device, replace the USB cable with a known good cable, and power up the device.

If all troubleshooting fails, see Getting Help.

Troubleshooting A Serial I/O Device

1.Turn off the system and any peripheral devices connected to the serial port.

2.Swap the serial interface cable with a working cable, and turn on the system and the serial device. If the problem is resolved, replace the interface cable with a known good cable.

3.Turn off the system and the serial device, and swap the device with a comparable device.

4.Turn on the system and the serial device.

If the problem persists, see Getting Help.

Troubleshooting A NIC

1.Run the appropriate diagnostic test. See Using System Diagnostics for available diagnostic tests.

2.Reboot the system and check for any system messages pertaining to the NIC controller.

3.Check the appropriate indicator on the NIC connector:

If the link indicator does not light, check all cable connections.

If the activity indicator does not light, the network driver files might be damaged or missing. Remove and reinstall the drivers if applicable. See the NIC's documentation.

If applicable, change the autonegotiation setting.

Use another connector on the switch or hub.

4.Ensure that the appropriate drivers are installed and the protocols are bound. See the NIC's documentation.

5.Enter the System Setup and confirm that the NIC ports are enabled on the Integrated Devices screen.

6.Ensure that the NICs, hubs, and switches on the network are all set to the same data transmission speed and duplex. See the documentation for each network device.

7.Ensure that all network cables are of the proper type and do not exceed the maximum length.

If all troubleshooting fails, see Getting Help.

Troubleshooting A Wet System

CAUTION: Many repairs may only be done by a certified service technician. You should only perform troubleshooting and simple repairs as authorized in your product documentation, or as directed by the online or telephone service and support team. Damage due to servicing that is not authorized by Dell is not covered by your warranty. Read and follow the safety instructions that came with the product.

1.Turn off the system and attached peripherals, and disconnect the system from the electrical outlet.

2.Open the system.

110

Image 110
Contents Regulatory Model E21S Series Regulatory Type E21S001 Page Contents Installing System Components Removing the Processor Expansion ModuleInternal USB Memory Key Optional Jumpers And Connectors Troubleshooting Your SystemUsing System Diagnostics 149 125131 Page Front-Panel Features And Indicators Indicator, Button, or Icon Description ConnectorLCD Panel Features LCD panelView Menu Setup MenuHome Screen Hard-Drive Indicator Patterns Seconds Back-Panel Features And IndicatorsSteady green Drive online Blinks green three NIC Indicator Codes Indicators are off Link indicator isPower Indicator Condition Pattern Not lit Power Indicator CodesIndicator Indicator Code Link indicator is Other Information You May Need F10 Choosing The System Boot ModeKeystroke Description F11Responding To Error Messages Entering System SetupSystem Setup Options Using The System Setup Navigation KeysSystem Information Screen System Setup Main ScreenSystem Bios Screen Memory Settings Screen Processor Settings ScreenExecute Disable Option is set to EnabledIP Prefetcher option is set to Enabled Execute Disable option is set to EnabledIntegrated Devices Screen Sata Settings ScreenBoot Settings Screen Serial Communications Screen System Profile Settings Screen System Security Screen Assigning a System And/Or Setup Password System And Setup Password FeaturesMiscellaneous Settings Page Operating With a Setup Password Enabled Entering The Uefi Boot ManagerUsing Your System Password To Secure Your System Using The Boot Manager Navigation Keys Boot Manager ScreenEntering The iDRAC Settings Utility IDRAC Settings UtilityUefi Boot Menu Changing The Thermal SettingsPage Page Removing The Front Bezel Recommended ToolsFront Bezel Optional Opening The System Installing The Front BezelOpening And Closing The System Inside The System Closing The SystemInside a Two-Processor System Processor Expansion Module Removing the Processor Expansion ModulePage Alignment guide left Release lever Support pins Installing The Processor Expansion Module Removing The Cooling Shroud Installing The Cooling ShroudCooling Shroud Installing The Top Cover Lock Latch Top Cover Lock LatchSystem Memory Memory Socket Locations on the System Board Processor Channel 0 slots A1, A5, and A9General Memory Module Installation Guidelines Mode-Specific GuidelinesSample Memory Configurations Advanced ECC Lockstep1R x8, 1333 MT/s 1R x8, 1600 MT/s A1, A2, B1, B2 B4 and 8 GB DIMMs A5, A6, B5 and B6D9, D10, D11, D12 Removing Memory Modules 2048 8R x4, 1600 MT/sInstalling Memory Modules Ejecting The Memory ModuleInstalling The Memory Module Hard Drives Removing a 2.5 Inch Hard-Drive BlankRemoving a Hot-Swap Hard Drive Installing a 2.5 Inch Hard-Drive BlankInstalling a Hot-Swap Hard Drive Removing a Hard Drive From a Hard-Drive Carrier Removing The Optical Drive Installing a Hard Drive Into a Hard-Drive CarrierOptical Drive Optional Installing The Optical Drive Cooling FansRemoving and Installing a Cooling Fan Removing a Cooling FanInstalling The Cooling Fan Removing The Cooling-Fan AssemblyInstalling The Cooling-Fan Assembly Removing and Installing the Cooling-Fan AssemblyInternal USB Memory Key Optional Replacing The Internal USB KeyRiser PCIe Slot Expansion Cards Installation GuidelinesExpansion Cards And Expansion-Card Risers Height Length Link Width Slot WidthRemoving An Expansion Card From An Expansion-Card Riser 1 Or Expansion-card connector Expansion-card holder Grooves Removing An Expansion Card From The Expansion-Card Riser Close the system Expansion-card connector Expansion-card riser Installing An Expansion Card Into The Expansion-Card Riser Removing Expansion-Card Risers Riser guide-back right Expansion-card connector slot Removing and Installing the Expansion Card Riser Installing Expansion-Card Risers SD vFlash CardRemoving The Internal Dual SD Module Internal Dual SD ModuleReplacing An SD vFlash Card Installing the Internal Dual SD Module Removing and Installing the Internal Dual SD ModuleIntegrated Storage Controller Card Installing An Internal SD CardInternal SD Card Removing An Internal SD CardRemoving the SAS Cable Connector Removing The Integrated Storage Controller CardStorage-controller card Installing The Integrated Storage Controller Card Network Daughter CardRemoving The Network Daughter Card Lift the network daughter card out of the chassis Removing The Processor Installing The Network Daughter CardProcessors Heat sink Close-lock symbol Installing The Processor Removing and Installing a ProcessorPower Supplies Hot Spare FeatureRemoving An AC Power Supply Removing and Installing an AC Power SupplyInstalling An AC Power Supply Wiring Instructions For a DC Power SupplyRequired Wires Removing a DC Power Supply Assembling The DC Input Power WiresInstalling a DC Power Supply Removing and Installing a DC Power SupplyInstalling The Power Supply Blank System BatteryRemoving The Power Supply Blank Replacing The System BatteryReplacing the System Battery Hard-Drive BackplaneRemoving The Hard-Drive Backplane Hooks Cable securing guide Perc card System board Hard-drive backplane PCIe SSD backplane Release tab Connectors PCIe SSD C connector Hooks Securing slots Release tabs Installing The Hard-Drive Backplane Cabling Diagram-2.5 Inch x16 Hard-Drive BackplaneControl Panel Assembly Removing The Control-Panel AssemblyRemoving The System Board Installing The Control-Panel AssemblySystem Board Page Installing The System Board Removing and Installing the System BoardPage Troubleshooting a USB Device Troubleshooting External ConnectionsTroubleshooting The Video Subsystem Troubleshooting a Wet System Troubleshooting a Serial I/O DeviceTroubleshooting a NIC Troubleshooting a Damaged System Troubleshooting Cooling Problems Troubleshooting The System BatteryTroubleshooting Power Supplies Troubleshooting Cooling Fans Troubleshooting System MemoryTroubleshooting An Internal USB Key Troubleshooting An SD CardTroubleshooting a Hard Drive Troubleshooting An Optical DriveTroubleshooting a Tape Backup Unit Troubleshooting a Storage Controller Troubleshooting Expansion Cards Troubleshooting ProcessorsIf the problem persists, see Getting Help 118 Dell Online Diagnostics Dell Embedded System Diagnostics When To Use The Embedded System DiagnosticsLeast one event description is recorded Running The Embedded System DiagnosticsSystem Diagnostic Controls System Board Jumper Settings Jumper Setting DescriptionSystem Board Connectors Connector DescriptionRISER1 Disabling a Forgotten Password Memory Expansion slots using riser cardExpansion Bus Front Connectors BackDrives InternalConnectors Video Expanded Operating TemperatureRelative Humidity Environmental TemperatureTemperature Continuous Operation Maximum VibrationEnvironmental Gaseous Contamination130 Viewing LCD Messages System Error MessagesLCD Messages Removing LCD MessagesDetails Error CodeAMP0302 Message ActionBAT0017 Message ASR0003 MessageBAT0002 Message CPU0000 MessageCPU0204 Message CPU0010 MessageCPU0023 Message CPU0700 MessageCPU0704 Message CPU0702 MessageCPU0703 Message FAN0000 Message If the issue persists, see Getting HelpAction Reinstall or reconnect the hardware HWC2003 Message Details Fan operating speed is out of range ActionMEM0007 Message MEM0000 MessageMEM0001 Message MEM0701 MessagePCI1302 Message MEM1208 MessageMEM8000 Message PCI1304 MessagePCI1348 Message PCI1320 MessagePCI1342 Message PCI1360 MessagePSU0001 Message PST0128 MessagePST0129 Message PSU0002 MessagePSU0031 Message PSU0006 MessagePSU0016 Message PSU0032 MessagePSU0036 Message PSU0034 MessagePSU0035 Message PSU0037 MessageConfiguration and power consumption PSU1201 Message Power supply redundancy is lost DetailsSystem power inventory change System power consumptionRFM2001 Message RFM1014 MessageRFM1201 Message RFM2002 MessagePower. If problem persists call support SEL0006 Message All event logging is disabled DetailsAppear if the user disabled event logging Security may be compromisedFailures Issues persists, contact supportFailed TMP0121 MessageDiagnostic Messages Alert Messages148 Getting Help Contacting Dell