Spring Switzerland GmbH Ver. 1.61 manual Mii, Primary, Administrator

Page 23

23

Transmit based on [(source MAC address XOR'd with destination MAC address) modulo slave count]. This selects the same slave for each destination MAC address. This mode provides load balancing and fault tolerance. This mode provides fault tolerance and load balancing.

broadcast

Transmits everything on all slave interfaces. This mode provides fault tolerance.

802.3ad

IEEE 802.3ad Dynamic link aggregation. Creates aggregation groups that share the same speed and duplex settings. Utilizes all slaves in the active aggregator according to the 802.3ad specification. Require: a switch that supports IEEE 802.3ad Dynamic link aggregation.

balance-tlb

Channel bonding that does not require any special switch support. The outgoing traffic is distributed according to the current load (computed relative to the speed) on each slave. Incoming traffic is received by the current slave. If the receiving slave fails, another slave takes over the MAC address of the failed receiving slave. This mode provides fault tolerance and load balancing.

balance-alb

Adaptive load balancing: includes balance-tlb plus receive load balancing (rlb) for IPV4 traffic, and does not require any special switch support. The receive load balancing is achieved by ARP negotiation. The bonding driver intercepts the ARP Replies sent by the local system on their way out and overwrites the source hardware address with the unique hardware address of one of the slaves in the bond such that different peers use different hardware addresses for the server.

mii

Specifies the MII link monitoring frequency in milliseconds. This determines how often the link state of each slave is inspected for link failures. A value of zero disables MII link monitoring. A value of 100 is a good starting point. The use_carrier option, below, affects how the link state is determined. See the High Availability section for additional information. The default value is 0.

primary

A string (eth0, eth2, etc) specifying which slave is the primary device. The specified device will always be the active slave while it is available. Only when the primary is off-line will alternate devices be used. This is useful when one slave is preferred over another, e.g., when one slave has higher throughput than another. The primary option is only valid for active-backup mode.

5.2.1.3 Administrator

In this section you may change parameters of administrator’s access, enabling e-mail notification, downloading SLL Certificate for your browser and defining power button action.

Image 23
Contents Manual Ver .61 May 02 Description of functions Hardware installationConfiguration Before you get startedTroubleshooting Guide Appendix a Appendix B Disclaimer CopyrightTrademarks System requirements Content of this packageBefore you get started Required tools Safety precautionsSupported clients Supported network protocolsDescription of the functions FeaturesWhat is iSCSI? Why Open-E iSCSI?RAID types Getting ready Hardware installationInstalling Open-E iSCSI Page First-time operation of Open-E iSCSI ConfigurationBasic configuration of the iSCSI computer Logging into Open-E iSCSI Enterprise Page Create RAID Units Adding Disk Units Creating iSCSI targets volumePage Configuring end user workstation How to connect iSCSI in Windows 2000/XP/2003 Description of functions Server Functions of Open-E iSCSI via browser access F1, F2 and F5 Shutting down and restartingNetwork Function Language SettingsSet bonding Function IP addressFunction Ipsec Function BondingPrimary AdministratorMii Function Administrator Access Function Administrator PasswordFunction E-mail notification Function USE Snmp How to retrieve information from SNMP?Function SSL Certificate Authority You can get information by Function Remote accessHardware Function UPS configuration Function Clock settings Target Manager Function Unit Manager Function Power button settingsFunction Set time Function Motherboard infoFunction Units Assigned Function iSCSI Volume ManagerFunction Disks Localizer Function Number of snapshots Function Snapshot definition Function Create new target Function Chap User Target AccessFunction Target IP Access Function Target Volume ManagerFunction Target Remove Function Chap User Target Snapshot AccessFunction Target Rename Function Create new Chap user Function Target Snapshot AccessFunction Snapshot rename Function Delete Chap user Function Edit Chap userUsing snapshot with Open-E iSCSI Function System Restart Shutdown Function System ShutdownFunction Schedule for shutdown Miscellaneous Function Connection resetSnapshot Software Update During update from CD please follow this steps Function Update downloaderFailed 2.5 S.M.A.R.T Function S.M.A.R.T. e-mail notificationHardware Page Function S.M.A.R.T. unit’s health status 3.3 S.M.A.R.TFunction S.M.A.R.T. info 4.1 H/W Raid Function 3ware administrationsFunction S.M.A.R.T. test Function Create new S/W RAID unit Function Qlogic administrationFibre Channel 4.3 S/W RaidAvailable Raids RAID 6 layout parity-algorithm RAID 5 layout parity-algorithmFunction S/W RAID E-mail notification RAID Function „ManagerFunction „Software RAID unit remove Function „InfoPage Error passwords do not match Troubleshooting GuideOpen-E iSCSI does not boot, keyboard LEDs are flashing Error values are not validIntellectual Property Rights Appendix aOpen-E Software License agreement Ownership and CopyrightWaiver Authorized ServiceDisclaimer of Warranties Limitation of LiabilityGNU General Public License Appendix BPage Page Page Page Page No Warranty How to Apply These Terms to Your New Libraries