FieldServer FS-8700-40 instruction manual Bell 2 Isolated, Bell 2 DE-ISOLATED

Page 25

FS-8700-40 SBT FSI Driver Manual

Page 25 of 29

 

 

Trouble Type

Trouble Type Text

56

Warm Reset

 

 

57

Printer out of Power

 

 

58

Tamper Switch

 

 

59

Battery Backup Invalid

 

 

60

Positive Ground Fault

 

 

61

Negative Ground Fault

 

 

62

AC Fail/brownout

 

 

63

System Signal Power Failure

 

 

64

Battery Fuse/Wiring Open

 

 

65

 

 

 

66

24 Volt Supply Over/Under

 

 

67

High Battery Voltage

 

 

68

Battery Charger Off

 

 

69

24 Volts on Battery Backup

 

 

70

Low Battery voltage

 

 

71

Watchdog Triggered

 

 

72

Device LED Manually Activated

 

 

73

Alarm queue full

 

 

74

Supervisory queue full

 

 

75

Trouble queue full

 

 

76

Security queue full

 

 

77

Memory error in Ram text

 

 

78

Memory error in ROM text

 

 

79

Aux Pwr Class A Fail Pos

 

 

80

Aux Pwr Class A Fail Neg

 

 

81

Supervisory Point

 

 

82

Security Point

 

 

83

BELL 2 ISOLATED

 

 

84

BELL 2 DE-ISOLATED

 

 

85

Configuration Error

 

 

86

Addressable Relay Isolated

 

 

87

Relay Isolated

 

 

88

Single Circuit Isolated

 

 

89

Solid State Output Isolated

 

 

90

Class A Fault

 

 

91

Noise Fault

 

 

92

MOI-1 Local Fault

 

 

93

MOI-1 Zone Isolated

 

 

94

PSR-1 Driver Isolated

 

 

95

Fault queue full

 

 

96

Isolated Alarm queue full

 

 

97

Isolated Alarm point

 

 

98

Requires Service

 

 

99

MVP General Trouble

 

 

100

Valve Tamper queue full

 

 

Trouble Type

Trouble Type Text

101

Valve Tamper Point

 

 

102

WALKTEST Activated

 

 

103

Function Recursion Limit Exceeded

 

 

104

Trouble Causing Input

 

 

105

Carrier Loss

 

 

106

 

 

 

107

Missing Device ID Response

 

 

108

Annunciator Trouble

 

 

109

CMI-300 general trouble

 

 

110

ROM SW version error

 

 

111

Lamp Supervision Trouble

 

 

112

Keyswitch Activated

 

 

113

Ancillary Cntrl Funcs Isolated

 

 

114

Ancillary Cntrl Funcs De-Isolated

 

 

115

Pre-dirty Analog volt reached

 

 

116

IEC limit reached. Service Req

 

 

117

IEC memory error

 

 

118

NET-7 General Trouble

 

 

119

Network B Pair Failure

 

 

120

MOI-1 Voice System Trouble

 

 

121

Style 4 Network mode

 

 

122

Aux. RS232 Transmit Fail

 

 

123

Module Address Buffer Fail

 

 

124

Incorrect Enclosure

 

 

125

OCC-1 General Trouble

 

 

126

OCC-1 Degrade Mode

 

 

127

Backup Tone Card (BTC)

 

 

128

Daily detector test abnormal

 

 

129

Event log 80% full

 

 

130

Event log 90% full

 

 

131

Log FULL, events will be lost

 

 

132

Audio Riser 1 Trouble

 

 

133

Audio Riser 2 Trouble

 

 

134

Audio Riser 3 Trouble

 

 

135

Mic Key Trouble

 

 

136

Mic Pre-amp Trouble

 

 

137

Tone Generator Trouble

 

 

138

Mic Input Trouble

 

 

139

Telephone Riser Trouble

 

 

140

Mic Key Trouble

 

 

141

Amplifier 1 Trouble

 

 

142

Amplifier 2 Trouble

 

 

143

Amplifier 3 Trouble

 

 

144

Amplifier 1 Backed Up

 

 

145

Amplifier 2 Backed Up

 

 

FieldServer Technologies 1991 Tarob Court Milpitas, California

95035 USA Web: www.fieldserver.com

Tel: (408) 262 2299 Fax: (408) 262 2269 Toll Free: (888) 509

1970 email: support@fieldserver.com

Image 25 Contents
Sierra Monitor Company Applicability & EffectivityTable of Contents Supplied by FieldServer Technologies for this driver Required 3r d Party ConfigurationProvided by the Supplier of 3rd Party Equipment Hardware FS-8700-40 SBT FSI Driver ManualHardware Connections Using the NIM-1R or NIM-1W for MXLFSI FSI Connection NotesConfiguring the Fieldserver AS a SBT-FSI Client FS-8700-40 SBT FSI Driver Manual Section Title Data ArraysColumn Title Function Legal Values ExampleSBT-FSI Client Side Connection DescriptionsMXL, XLS Second ExampleClient Side Node Descriptors Timing Parameters Driver Related Map Descriptor ParametersFS-8700-40 SBT FSI Driver ManualPage 11 XLSRdbc FS-8700-40 SBT FSI Driver Manual Map Descriptor example 2 Monitoring Analog Loop Devices Advanced Client Configuration Using Bidirectional Capability Device Type Configuring the Fieldserver AS a SBT-FSI ServerNone Server Side Connection DescriptorsServer Side Node Descriptors FS-8700-40 SBT FSI Driver ManualPage 19 Driver Specific Map Descriptor ParametersFS-8700-40 SBT FSI Driver Manual FS-8700-40 SBT FSI Driver Manual Example 1 Only receive events from panel Appendix A.1. Specifying a Poller Map Descriptor lengthExample 2 Receive events from panel 7 Trouble Appendix A.2. Interpreting Panel Error MessagesMXL/XLS Trouble Codes Appendix A.4. Using Trouble CodesInput DE-ISOLATED Input IsolatedBell 2 DE-ISOLATED Bell 2 IsolatedFS-8700-40 SBT FSI Driver Manual MXL Appendix A.5. Activating and De-activating EntitiesMXL Appendix A.6. Arming and De-Arming EntitiesXLS