FieldServer FS-8700-40 Appendix A.4. Using Trouble Codes, MXL/XLS Trouble Codes, Input Isolated

Page 24

FS-8700-40 SBT FSI Driver Manual

Page 24 of 29

 

 

Appendix A.4. Using Trouble Codes

In order to see the trouble codes for incoming troubles it is necessary to use a Uint16 or Int16 data array for the trouble instead of the normal Bit. When the driver stores a trouble code of for example 15 into a Bit data array, it will be displayed as 1 since Bit only holds either a zero or a one value. Using a Uint16 or Int16 data array will ensure the value of 15 is displayed.

The following information is taken from Siemens Fire Safety documentation

MXL/XLS Trouble Codes

These codes are sent in Field 5 of the Trouble in, Trouble out and Trouble Acknowledge messages 24H, 25H and 26H. Each code is sent as up to 3 ASCII bytes. Leading zeros are not sent. The Request Trouble Type message (43H) can be used to obtain the text strings shown below for each of these codes. The trouble text string is returned in the Trouble Type message (53H).

Trouble Type

Trouble Type Text

0

 

 

 

1

Multiple Response

 

 

2

Communication Error

 

 

3

Input Dev. Response too low

 

 

4

Device Receive Error

 

 

5

Dev Detected Waveform Error

 

 

6

Not Responding

 

 

7

Not Responding

 

 

8

Unspecified Dev. Responding

 

 

9

Incorrect ID

 

 

10

INPUT DE-ISOLATED

 

 

11

INPUT ISOLATED

 

 

12

Input Disarmed

 

 

13

Addressable Relay disarmed

 

 

14

Relay Disarmed

 

 

15

Signal Circuit Disarmed

 

 

16

Solid State Output Disarmed

 

 

17

Relay Supervision Failure

 

 

18

Signal Circuit Loop Open

 

 

19

Loop Disarmed

 

 

20

Class A Trouble

 

 

21

Relay Driver Inoperative

 

 

22

Signal Circuit Shorted

 

 

23

ALD Reception Error

 

 

24

Coil Open

 

 

25

Zone Power Off

 

 

26

Power Cycling

 

 

27

Short Circuit

 

 

Trouble Type

Trouble Type Text

28

Open Circuit

 

 

29

Voltage Low

 

 

30

Zone Power Loss

 

 

31

Loop Node

 

 

32

Not defined

 

 

33

Multiple Response

 

 

34

MOI-1 Local Trouble

 

 

35

MOI-1 Zone Trouble

 

 

36

No database – default in use

 

 

37

Too Many ALD-2’s

 

 

38

PSR-1 Driver Disarmed

 

 

39

Output Disarmed

 

 

40

Not Responding

 

 

41

Unspecified Module Responding

 

 

42

Communication Failure

 

 

43

RAM Failure

 

 

44

ROM Failure

 

 

45

A/D Convert Fail

 

 

46

Single Module Zone Code

 

 

47

Command Not Valid

 

 

48

Network A Pair Fail

 

 

49

 

 

 

50

Loss of 24V Input Power

 

 

51

Act Power Voltage Low

 

 

52

Default Trouble Active

 

 

53

Network Disabled

 

 

54

Alarm from Isolated Device

 

 

55

Printer off-line

 

 

FieldServer Technologies 1991 Tarob Court Milpitas, California

95035 USA Web: www.fieldserver.com

Tel: (408) 262 2299 Fax: (408) 262 2269 Toll Free: (888) 509

1970 email: support@fieldserver.com

Image 24
Contents Applicability & Effectivity Sierra Monitor CompanyTable of Contents Required 3r d Party Configuration Supplied by FieldServer Technologies for this driverProvided by the Supplier of 3rd Party Equipment Hardware FS-8700-40 SBT FSI Driver ManualUsing the NIM-1R or NIM-1W for MXL Hardware ConnectionsFSI Connection Notes FSIConfiguring the Fieldserver AS a SBT-FSI Client FS-8700-40 SBT FSI Driver Manual Data Arrays Section TitleColumn Title Function Legal Values ExampleClient Side Connection Descriptions SBT-FSIMXL, XLS Second ExampleClient Side Node Descriptors Driver Related Map Descriptor Parameters Timing ParametersFS-8700-40 SBT FSI Driver ManualPage 11 XLSRdbc FS-8700-40 SBT FSI Driver Manual Map Descriptor example 2 Monitoring Analog Loop Devices Advanced Client Configuration Using Bidirectional Capability Configuring the Fieldserver AS a SBT-FSI Server Device TypeServer Side Connection Descriptors NoneServer Side Node Descriptors Driver Specific Map Descriptor Parameters FS-8700-40 SBT FSI Driver ManualPage 19FS-8700-40 SBT FSI Driver Manual FS-8700-40 SBT FSI Driver Manual Appendix A.1. Specifying a Poller Map Descriptor length Example 1 Only receive events from panelExample 2 Receive events from panel 7 Appendix A.2. Interpreting Panel Error Messages TroubleAppendix A.4. Using Trouble Codes MXL/XLS Trouble CodesInput DE-ISOLATED Input IsolatedBell 2 Isolated Bell 2 DE-ISOLATEDFS-8700-40 SBT FSI Driver Manual Appendix A.5. Activating and De-activating Entities MXLAppendix A.6. Arming and De-Arming Entities MXLXLS

FS-8700-40 specifications

The FieldServer FS-8700-40 is an advanced protocol gateway that plays an essential role in the integration of diverse building management systems and industrial automation environments. Renowned for its robustness and versatility, the FS-8700-40 is engineered to facilitate seamless communication between a variety of devices and networks, which enhances operational efficiency and flexibility.

One of the standout features of the FS-8700-40 is its support for multiple protocols. The device is compatible with a wide range of protocols prevalent in the industry, including BACnet, Modbus, LonWorks, and many others. This multi-protocol capability allows users to connect devices from different manufacturers without the need for extensive customization or the installation of multiple gateways, thus simplifying system architecture and reducing costs.

The FS-8700-40 is equipped with a powerful microprocessor that ensures high performance and reliability. Its processing capabilities enable it to handle complex data exchanges and logic operations, making it suitable for both small scale and large scale applications. The device also features an extensive memory capacity, aiding in the storage and retrieval of large datasets necessary for sophisticated control strategies and reporting functionalities.

Another prominent characteristic of the FS-8700-40 is its user-friendly interface. The device comes with a web-based graphical user interface (GUI) that allows for easy configuration and monitoring. Users can easily set up and modify communication parameters, visualize data trends, and implement system changes in real time, all from an accessible online portal. This enhances user experience and decreases the time needed for system maintenance and updates.

Security is also a critical consideration in the design of the FS-8700-40. The device incorporates advanced security measures to protect sensitive data and ensure secure communication between connected devices. This includes features such as user authentication, data encryption, and secure sockets layer (SSL) support, which fortify the overall integrity of the system.

In addition to its technological prowess, the FS-8700-40 is designed to be highly durable and reliable in various operational conditions. With features like temperature resistance and surge protection, it boasts an extended lifespan and requires minimal maintenance, making it a cost-effective solution for users.

In summary, the FieldServer FS-8700-40 stands out due to its multi-protocol support, high processing capabilities, user-friendly interface, robust security, and durability. Its ability to facilitate communication between heterogeneous systems makes it an indispensable tool for businesses looking to optimize their operational efficiency and future-proof their infrastructure.