Message

 

 

 

Description

 

 

 

MET1:#07 Err. Cant find DA=%s

 

 

 

 

to get Mode.

 

 

 

 

 

 

 

MET1:#07b Err. Cant find DA=%s

Printed by the Server side of the driver. The Server cant

 

 

to set Mode.

 

 

 

find the specified DA which will be used to store incoming

 

 

 

 

 

 

 

 

MET1:#07c Err. Cant find DA=%s

data or from which data will be extracted to form a

 

 

response.3

 

 

 

to get current record.

 

 

 

 

 

 

MET1:#07d Err. Cant find DA=%s

 

 

 

 

to store times.

 

 

 

 

 

 

 

MET1:#08a

Err.

Invalid

time

 

 

 

 

string=%s

 

 

 

Printed by the Server side of the driver. See notes for #4.

 

 

MET1:#08b

Err.

Invalid

time

 

 

string=%s

 

 

 

 

 

 

 

 

 

 

 

The reported MD has a Met1 function not recognized by

 

 

MET1:#09a

 

 

Err.

the driver. This should never happen. Take a log and send

 

 

Met1_Function=%d is unknown.

a copy of the log and your configuration to Tech Support.

 

 

MD=%s

 

 

 

The FieldServer web site provide tools and instructions for

 

 

 

 

 

 

taking logs

 

 

 

 

 

 

 

This messages is printed a maximum of 15 times and then

 

 

 

 

 

 

suppressed.

 

 

 

 

 

 

 

Where the label method is being used to store data. (See

 

 

 

 

 

 

section 4.13) then this message is printed if the driver can’t

 

 

Met1:#10 FYI. No place to store

find an Map Descriptor with a label which matches the

 

 

label data. Label=%s MD=%s

 

reported label found in the message from the field device.

 

 

 

 

 

 

The message is printed simply to alert users to what count

 

 

 

 

 

 

labels are being returned. Passive Map Descriptors can

 

 

 

 

 

 

be created to store the reported data, or the message

 

 

 

 

 

 

could be ignored.

 

 

 

MET1:#11a Err. Diagnostic 6

 

 

 

 

 

MET1:#11b Err. Diagnostic 1

 

Printed by the Server side of the driver. These are printed

 

 

 

 

 

 

when internal diagnostics are triggered. This should never

 

 

MET1:#11c Err. Diagnostic 4

 

be the case in an operational system. Take a log and

 

 

 

 

 

 

contact Tech Support. The FieldServer web site provide

 

 

MET1:#11d Err. Diagnostic 2

 

tools and instructions for taking logs

 

 

 

MET1:#11e Err. Diagnostic 7

 

 

 

 

 

MET1:#12 FYI. Use an Array

This message can be ignored. For more information read

 

 

called <%s> to expose diagnostic

Appendix A.2

 

 

 

info.

 

 

 

 

 

 

3Update the configuration file, download the modified configuration file and reset the FieldServer for the changes to take effect.

FieldServer Technologies 1991 Tarob Court Milpitas, California 95035 USA Web:www.fieldServer.com Tel: 408 262-2299 Fax: 408-262-2269 Toll_Free: 888-509-1970 email: support@fieldServer.com

Image 22
Contents MetOne Particle Counters Applicability & EffectivityTable of Contents MetOne Particle Counter Serial Description FS-8700-123 MetOne Particle Counter Serial Driver Manual Hardware Connections Hardware Connection Tips / Hints RS-232 PortConfiguring the FieldServer as a MetOne PC Serial Client Data Arrays/DescriptorsClient Side Node Descriptors Client Side Connection DescriptionsHF CNC Driver Related Map Descriptor Parameters Timing ParametersDatimes Rdbc MET1 Map Descriptor Example 3 Read the operating mode Datimes Wrbx MET1Map Descriptor Example 4 Start / Stop Counting Map Descriptor Example 5 Change Mode Map Descriptor Example 6 Select Device Map Descriptor Example 7 Read the Current Record Map Descriptor Example 8 Dumping the Current Record DACURRD01LBL ,0 Map Descriptor Example 10 Reading from a SubDevice/Port Map Descriptor Example 11 Selecting a Sub-Device/Port Configuring the FieldServer as a MetOne PC Serial Server Appendix A. Driver Error Messages Page Appendix A.1. Driver Operating and Error Statistics FYIAppendix A.2. Driver Exposed Operating and Error Statistics UINT32Page This page Intentionally Left Blank