Maxtor STM3160813AS, STM31000334AS manual Supported ATA commands, Command name Command code in hex

Page 33

4.3Supported ATA commands

The following table lists Serial ATA standard commands that the drive supports. For a detailed description of the ATA commands, refer to the Serial ATA International Organization: Serial ATA Revision 2.6 (http:// www.sata-io.org). See “S.M.A.R.T. commands” on page 34 for details and subcommands used in the S.M.A.R.T. implementation.

Table 8: Supported ATA commands

Command name

Command code (in hex)

 

 

Check Power Mode

E5H

Device Configuration Freeze Lock

B1H / C1H

Device Configuration Identify

B1H / C2H

Device Configuration Restore

B1H / C0H

Device Configuration Set

B1H / C3H

Device Reset

08H

Download Microcode

92H

Execute Device Diagnostics

90H

Flush Cache

E7H

Flush Cache Extended

EAH

Format Track

50H

Identify Device

ECH

Idle

E3H

Idle Immediate

E1H

Initialize Device Parameters

91H

Read Buffer

E4H

Read DMA

C8H

Read DMA Extended

25H

Read DMA Without Retries

C9H

Read Log Ext

2FH

Read Multiple

C4H

Read Multiple Extended

29H

Read Native Max Address

F8H

Read Native Max Address Extended

27H

Read Sectors

20H

Read Sectors Extended

24H

Read Sectors Without Retries

21H

Read Verify Sectors

40H

Read Verify Sectors Extended

42H

Read Verify Sectors Without Retries

41H

Recalibrate

10H

Security Disable Password

F6H

Security Erase Prepare

F3H

DiamondMax 22 Serial ATA Product Manual, Rev. A

27

Image 33
Contents STM31000334AS STM3320614AS STM3160813AS DiamondMax 22 Serial ATARevision Date Sheets affected or comments Rev. a 11/04/08 Initial releaseContents DiamondMax 22 Serial ATA Product Manual, Rev. a Typical 5V startup and operation current profile List of FiguresPage Introduction About the Serial ATA interface Drive specifications Drive specifications summary for 1000 Gbyte models DiamondMax 22 Serial ATA Product Manual, Rev. a Drive specifications summary for 320 and 160 Gbyte models DiamondMax 22 Serial ATA Product Manual, Rev. a LBA mode Default logical geometryFormatted capacity Recording and interface technologyPhysical characteristics Seek timeTypical seek times msec Read Write Start/stop times Power specificationsDC power requirements Typical 12V startup and operation current profile Typical 5V startup and operation current profileActive mode Power-management modesIdle mode Sleep modeEnvironmental specifications Operating shock ShockNonoperating shock GB models 160 GB modelsElectromagnetic immunity AcousticsFluid Dynamic Bearing FDB motor acoustics Test for Prominent Discrete Tones PDTsReliability Safety certificationAgency certification Electromagnetic compatibilityKorean RRL Australian C-Tick N176FCC verification 13.2 Environmental protectionCorrosive environment China Restriction of Hazardous Substances RoHS DirectiveDiamondMax 22 Serial ATA Product Manual, Rev. a Handling and static-discharge precautions Configuring and mounting the driveSerial ATA cables and connectors Configuring the driveDrive mounting Mounting dimensions 1000 GB modelsMounting dimensions 320 and 160 GB models Hot-Plug compatibility Serial ATA Sata interfaceSerial ATA connector pin definitions Serial ATA device plug connector pin definitionsSignal Pin Function DefinitionSupported ATA commands Supported ATA commandsCommand name Command code in hex F4H Word Description Value Identify Device commandXx07H Bit Word Description if bit is set to Bit WordWord Set Features command values Set Features command3 S.M.A.R.T. commands M.A.R.T. commandsCode in features register A.R.T. command Internet Seagate Technology support servicesPresales Support Technical SupportWarranty Service Data Recovery Services Authorized Service CentersData Recovery Services Call Center Toll-free Direct dial Index ITE Page DiamondMax 22 Serial ATA Product Manual, Rev. a Page Seagate Technology LLC