Maxtor 300 manual 5J1 DC Power and Pata Bus Combination Connector

Page 26

Installation

Center

Key Slot

Pin 1

J1 IDE (40-Pin)/DC (4-Pin)

Combination Connector

40-Pin IDE

 

 

4-Pin DC Power

Pin 1

 

(J1 Section A)

(J1 Section C)

 

 

 

4

3

2

1

 

 

 

Pin 40

 

Pin 42

Pin 44

 

 

 

Figure 3-5J1 DC Power and PATA Bus Combination Connector

3-10 Quickview 300 80/100/120/160/200/250/300GB PATA

Image 26
Contents MaxtorQuickview 80/100/120/160/200/250/300GB Pata Patents Publication Number Part Number Before You Begin McCarthy Blvd Milpitas, California Tel Fax Chapter InstallationChapter Introduction General DescriptionService and Support Product SpecificationsATA BUS Interface and ATA Commands Appendix a Breaking the 137 Gigabyte Storage BarrierList of Figures List of Tables Products Maxtor CorporationAudience SupportManual Organization Terminology and ConventionsMSB References KEY Features Product OverviewGeneral Description Regulatory Compliance Standards Product EMI/EMS QualificationsInstallation Space RequirementsUnpacking Instructions 2Quickview 300 20-Pack Shipping Container Pata Interface Connector Hardware Options1AT Jumper Options Cable Select CS JumperMaster Jumper Configuration Drive Select DS JumperPower On Standby Cylinder Limitation Jumper CLJ4AT Connector and Jumper Location Pata BUS Adapter Combination Connector J12.1 40-Pin Pata Bus Connector Adapter Board5J1 DC Power and Pata Bus Combination Connector External Drive Activity LED DC Power J1, Section aPata Bus Interface Connector J1, Section C Mounting Orientation Installation Ventilation Adapter Board InstallationClearance For Systems With a Motherboard Pata AdapterConnecting the Adapter Board and the Drive 8Drive Power Supply and Pata Bus Interface CablesTechniques in Drive Configuration Operating system limitationsDrive Configuration Models and CapacitiesPerformance Specifications Physical Dimensions Parameter ValueVoltage Tolerance Power Requirements for 80/100/120/160/200GB TypicalPower Requirements for 250GB/300GB Typical Power Mode Definitions EPA Energy Star ComplianceEnvironmental Limits Acoustic Noise11Baseplate Tempurature Measurement Location Shock and Vibration Parameter Operating NON-OPERATINGStart/Stop Cycles Reliability SpecificationsAnnualized Return Rate Data ReliabilitySafety Regulatory Compliance Canadian Emissions StatementMechanical Interface Signal Cable and ConnectorIntroduction Electrical InterfaceSupported Commands Command InterfaceGeneral Feature Set Command Feature Register Code ValuesFlush Cache SET Multiple Mode Write Sectors 30hContent Description Word10-19 Serial number 20 Ascii characters 20-21 Retired Content Description Minimum PIO transfer cycle time without flow control Minor version number See Address Offset Reserved Area Boot, Incits TR272001 = release interrupt enabled Supported Content Description Reserved 255 Integrity word 15-8 Checksum Signature Service and Support Product Support/Technical Assistance/Customer ServiceBreaking the 137 Gigabyte Storage Barrier HistoryDOS What Do the Drives Need to Meet the Spec? Solving the 137 Gigabyte Capacity BarrierHow is the Extension Implemented? Appendix a What is the Next Barrier?What Else is Involved? Appendix B Big Numbers Appendix CGlossary Glossary FCI Acronym for flux changes per inch. See also BPI Initialize See low level formatting Millisecond ms One thousandth of a second .001 sec Glossary Quickview 300 80/100/120/160/200/250/300GB Pata G-7 Glossary Index