Maxtor 300 manual Shock and Vibration, Parameter Operating NON-OPERATING

Page 40

Product Specifications

4.9Shock and Vibration

PARAMETER

OPERATING

NON-OPERATING

 

 

 

Mechanical Shock

R=0.988/shock at 60 Gs;

2 msec, 1/2 sine

 

R= 0.999/shock at 30 Gs

R=0.90@>= 300G

 

 

R=0.95@>= 250G

 

 

R=0.99@>= 200G

 

 

 

Rotational Shock

R=0.988 @ 2000 rad/sec2

R=0.95 @ 20K rad/sec2,

 

 

1ms input

 

 

R=0.90 @ 20K rad/sec2,

 

 

1ms input

 

 

 

Rotational Random

5 - 2000 Hz

2 - 300 Hz

Vibration

3.60 rad/sec2 RMS Overall

96.5 rad/sec2 RMS

Random Vibration

5 - 2000 Hz

PSD:

 

0.44 GRMS Overall

7 - 800 Hz at 3.08 GRMS

 

 

No Damage

 

 

 

Swept Sine Vibration

 

 

(1 octave/minute,

 

 

peak amplitude)

1.0 G (0 to peak) amplitude,

 

10 to 300 Hz

 

 

1 octave per minute

 

301 to 400 Hz

0.25 G (0 to peak) amplitude,

 

 

1 octave per minute

 

401 to 500 Hz

0.0625 G (0 to peak) amplitude,

 

 

1 octave per minute

 

 

 

 

Operating Sine Vibra-

Frequency (Hz) / Acceleration (Gpk)

 

tion 0.25 octave/

5 / 0.25”DA

 

min., 5-1500 Hz

8.8 / 0.25”DA

 

 

9 / 1.000

 

 

100 / 1.000

 

 

300 / 0.060

 

 

885 / 0.060

 

 

890 / 0.100

 

 

895 / 0.070

 

 

1500 / 0.100

 

 

 

 

4-8 Quickview 300 80/100/120/160/200/250/300GB PATA

Image 40
Contents MaxtorQuickview 80/100/120/160/200/250/300GB Pata Patents Publication Number Part Number Before You Begin McCarthy Blvd Milpitas, California Tel Fax Installation Chapter IntroductionChapter General DescriptionATA BUS Interface and ATA Commands Product SpecificationsService and Support Appendix a Breaking the 137 Gigabyte Storage BarrierList of Figures List of Tables Maxtor Corporation AudienceProducts SupportManual Organization Terminology and ConventionsMSB References KEY Features Product OverviewGeneral Description Regulatory Compliance Standards Product EMI/EMS QualificationsInstallation Space RequirementsUnpacking Instructions 2Quickview 300 20-Pack Shipping Container Pata Interface Connector Hardware Options1AT Jumper Options Cable Select CS JumperMaster Jumper Configuration Drive Select DS JumperPower On Standby Cylinder Limitation Jumper CLJ4AT Connector and Jumper Location Combination Connector J1 2.1 40-Pin Pata Bus ConnectorPata BUS Adapter Adapter Board5J1 DC Power and Pata Bus Combination Connector Pata Bus Interface Connector J1, Section C DC Power J1, Section aExternal Drive Activity LED Mounting Orientation Installation Adapter Board Installation ClearanceVentilation For Systems With a Motherboard Pata AdapterConnecting the Adapter Board and the Drive 8Drive Power Supply and Pata Bus Interface CablesTechniques in Drive Configuration Operating system limitationsDrive Configuration Models and CapacitiesPerformance Specifications Physical Dimensions Parameter ValuePower Requirements for 250GB/300GB Typical Power Requirements for 80/100/120/160/200GB TypicalVoltage Tolerance Power Mode Definitions EPA Energy Star ComplianceEnvironmental Limits Acoustic Noise11Baseplate Tempurature Measurement Location Shock and Vibration Parameter Operating NON-OPERATINGReliability Specifications Annualized Return RateStart/Stop Cycles Data ReliabilitySafety Regulatory Compliance Canadian Emissions StatementSignal Cable and Connector IntroductionMechanical Interface Electrical InterfaceCommand Interface General Feature SetSupported Commands Command Feature Register Code ValuesFlush Cache SET Multiple Mode Write Sectors 30hContent Description Word10-19 Serial number 20 Ascii characters 20-21 Retired Content Description Minimum PIO transfer cycle time without flow control Minor version number See Address Offset Reserved Area Boot, Incits TR272001 = release interrupt enabled Supported Content Description Reserved 255 Integrity word 15-8 Checksum Signature Service and Support Product Support/Technical Assistance/Customer ServiceBreaking the 137 Gigabyte Storage Barrier HistoryDOS How is the Extension Implemented? Solving the 137 Gigabyte Capacity BarrierWhat Do the Drives Need to Meet the Spec? What Else is Involved? What is the Next Barrier?Appendix a Appendix B Big Numbers Appendix CGlossary Glossary FCI Acronym for flux changes per inch. See also BPI Initialize See low level formatting Millisecond ms One thousandth of a second .001 sec Glossary Quickview 300 80/100/120/160/200/250/300GB Pata G-7 Glossary Index