ATA Bus Interface and ATA Commands

 

 

 

 

 

Table 5-2Identify Drive Command Parameters

 

 

 

 

Word

 

 

CONTENT DESCRIPTION

 

 

 

 

 

 

87

6:

1 = WRITE DMA FUA EXT and WRITE MULTIPLE FUA EXT commands

 

 

supported

 

 

 

 

5:

General Purpose Logging feature set supported

 

 

 

 

4:

1 = Valid CONFIGURE STREAM command has been executed

 

 

 

 

3:

1 = Media Card Pass Through Command feature set enabled

 

 

 

 

2:

1 = Media serial number is valid

 

 

 

 

1:

1 = SMART self-test supported

 

 

 

 

0:

1 = SMART error logging supported

 

 

 

88

15:

Reserved

 

 

 

 

 

14:

1

= Ultra DMA mode 6 is selected. 0 = Ultra DMA mode 6 is not selected

 

 

 

 

 

13:

1

= Ultra DMA mode 5 is selected. 0 = Ultra DMA mode 5 is not selected

 

 

 

 

 

12:

1

= Ultra DMA mode 4 is selected. 0 = Ultra DMA mode 4 is not selected

 

 

 

 

 

11:

1

= Ultra DMA mode 3 is selected. 0 = Ultra DMA mode 3 is not selected

 

 

 

 

 

10:

1

= Ultra DMA mode 2 is selected. 0 = Ultra DMA mode 2 is not selected

 

 

 

 

 

9:

1

= Ultra DMA mode 1 is selected. 0 = Ultra DMA mode 1 is not selected

 

 

 

 

 

8:

1

= Ultra DMA mode 0 is selected. 0 = Ultra DMA mode 0 is not selected

 

 

 

 

7:

Reserved

 

 

 

 

 

6:

1

= Ultra DMA mode 6 and below are supported

 

 

 

 

 

5:

1

= Ultra DMA mode 5 and below are supported

 

 

 

 

 

4:

1

= Ultra DMA mode 4 and below are supported

 

 

 

 

 

3:

1

= Ultra DMA mode 3 and below are supported

 

 

 

 

 

2:

1

= Ultra DMA mode 2 and below are supported

 

 

 

 

 

1:

1

= Ultra DMA mode 1 and below are supported

 

 

 

 

 

0:

1

= Ultra DMA mode 0 is supported

 

 

89

Time required for security erase unit completion

 

 

90

Time required for Enhanced security erase completion

 

 

91

Current advanced power management value

 

 

92

Master Password Revision Code

 

 

 

 

Quickview 300 80/100/120/160/200/250/300GB PATA

5-13

Image 55
Contents MaxtorQuickview 80/100/120/160/200/250/300GB Pata Patents Publication Number Part Number Before You Begin McCarthy Blvd Milpitas, California Tel Fax General Description InstallationChapter Introduction ChapterATA BUS Interface and ATA Commands Product SpecificationsService and Support Breaking the 137 Gigabyte Storage Barrier Appendix aList of Figures List of Tables Support Maxtor CorporationAudience ProductsTerminology and Conventions Manual OrganizationMSB References Product Overview KEY FeaturesGeneral Description Product EMI/EMS Qualifications Regulatory Compliance StandardsSpace Requirements InstallationUnpacking Instructions 2Quickview 300 20-Pack Shipping Container Hardware Options Pata Interface ConnectorCable Select CS Jumper 1AT Jumper OptionsDrive Select DS Jumper Master Jumper ConfigurationCylinder Limitation Jumper CLJ Power On Standby4AT Connector and Jumper Location Adapter Board Combination Connector J12.1 40-Pin Pata Bus Connector Pata BUS Adapter5J1 DC Power and Pata Bus Combination Connector Pata Bus Interface Connector J1, Section C DC Power J1, Section aExternal Drive Activity LED Mounting Orientation Installation For Systems With a Motherboard Pata Adapter Adapter Board InstallationClearance Ventilation8Drive Power Supply and Pata Bus Interface Cables Connecting the Adapter Board and the DriveOperating system limitations Techniques in Drive ConfigurationModels and Capacities Drive ConfigurationPerformance Specifications Parameter Value Physical DimensionsPower Requirements for 250GB/300GB Typical Power Requirements for 80/100/120/160/200GB TypicalVoltage Tolerance EPA Energy Star Compliance Power Mode DefinitionsAcoustic Noise1 Environmental Limits1Baseplate Tempurature Measurement Location Parameter Operating NON-OPERATING Shock and VibrationData Reliability Reliability SpecificationsAnnualized Return Rate Start/Stop CyclesCanadian Emissions Statement Safety Regulatory ComplianceElectrical Interface Signal Cable and ConnectorIntroduction Mechanical InterfaceCommand Feature Register Code Values Command InterfaceGeneral Feature Set Supported CommandsFlush Cache SET Multiple Mode 30h Write SectorsWord Content Description10-19 Serial number 20 Ascii characters 20-21 Retired Content Description Minimum PIO transfer cycle time without flow control Minor version number See Address Offset Reserved Area Boot, Incits TR272001 = release interrupt enabled Supported Content Description Reserved 255 Integrity word 15-8 Checksum Signature Product Support/Technical Assistance/Customer Service Service and SupportHistory Breaking the 137 Gigabyte Storage BarrierDOS How is the Extension Implemented? Solving the 137 Gigabyte Capacity BarrierWhat Do the Drives Need to Meet the Spec? What Else is Involved? What is the Next Barrier?Appendix a Appendix C Appendix B Big NumbersGlossary Glossary FCI Acronym for flux changes per inch. See also BPI Initialize See low level formatting Millisecond ms One thousandth of a second .001 sec Glossary Quickview 300 80/100/120/160/200/250/300GB Pata G-7 Glossary Index