Maxtor 300 manual Minor version number

Page 52

ATA Bus Interface and ATA Commands

 

 

Table 5-2Identify Drive Command Parameters

 

 

 

 

Word

 

 

CONTENT DESCRIPTION

 

 

 

 

81

Minor version number

 

 

 

0000h or FFFFh = device does not report version.

 

0001h-FFFEh = see 6.16.41 of ATA/ATAPI-7 specification

 

 

82

Command set supported.

 

 

 

 

15:

Obsolete

 

 

 

 

 

14:

1

= NOP command supported

 

 

 

 

 

13:

1

= READ BUFFER command supported

 

 

 

 

 

12:

1

= WRITE BUFFER command supported

 

 

 

 

11:

Obsolete

 

 

 

 

 

10:

1

= Host Protected Area feature set supported

 

 

 

 

 

9:

1

= DEVICE RESET command supported

 

 

 

 

 

8:

1

= SERVICE interrupt supported

 

 

 

 

 

7:

1

= release interrupt supported

 

 

 

 

 

6:

1

= look-ahead supported

 

 

 

 

 

5:

1

= write cache supported

 

 

 

 

4:

Shall be cleared to zero to indicate that the PACKET Command feature set is

 

 

not supported

 

 

 

 

 

3:

1

= mandatory Power Management feature set supported

 

 

 

 

 

2:

1

= Removable Media feature set supported

 

 

 

 

 

1:

1

= Security Mode feature set supported

 

 

 

 

 

0:

1

= SMART feature set supported

 

 

83

Command sets supported.

 

 

 

 

15:

Shall be cleared to zero

 

 

 

 

14:

Shall be set to on

 

 

 

 

 

13:

1

= FLUSH CACHE EXT command supported

 

 

 

 

 

12:

1

= mandatory FLUSH CACHE command supported

 

 

 

 

 

11:

1

= Device Configuration Overlay feature set supported

 

 

 

 

 

10:

1

= 48-bit Address feature set supported

 

 

 

 

 

9:

1

= Automatic Acoustic Management feature set supported

 

 

 

 

 

8:

1

= SET MAX security extension supported

 

 

 

 

5-10 Quickview 300 80/100/120/160/200/250/300GB PATA

Image 52
Contents MaxtorQuickview 80/100/120/160/200/250/300GB Pata Patents Publication Number Part Number Before You Begin McCarthy Blvd Milpitas, California Tel Fax Installation Chapter IntroductionChapter General DescriptionATA BUS Interface and ATA Commands Product SpecificationsService and Support Appendix a Breaking the 137 Gigabyte Storage BarrierList of Figures List of Tables Maxtor Corporation AudienceProducts SupportManual Organization Terminology and ConventionsMSB References KEY Features Product OverviewGeneral Description Regulatory Compliance Standards Product EMI/EMS QualificationsInstallation Space RequirementsUnpacking Instructions 2Quickview 300 20-Pack Shipping Container Pata Interface Connector Hardware Options1AT Jumper Options Cable Select CS JumperMaster Jumper Configuration Drive Select DS JumperPower On Standby Cylinder Limitation Jumper CLJ4AT Connector and Jumper Location Combination Connector J1 2.1 40-Pin Pata Bus ConnectorPata BUS Adapter Adapter Board5J1 DC Power and Pata Bus Combination Connector Pata Bus Interface Connector J1, Section C DC Power J1, Section aExternal Drive Activity LED Mounting Orientation Installation Adapter Board Installation ClearanceVentilation For Systems With a Motherboard Pata AdapterConnecting the Adapter Board and the Drive 8Drive Power Supply and Pata Bus Interface CablesTechniques in Drive Configuration Operating system limitationsDrive Configuration Models and CapacitiesPerformance Specifications Physical Dimensions Parameter ValuePower Requirements for 250GB/300GB Typical Power Requirements for 80/100/120/160/200GB TypicalVoltage Tolerance Power Mode Definitions EPA Energy Star ComplianceEnvironmental Limits Acoustic Noise11Baseplate Tempurature Measurement Location Shock and Vibration Parameter Operating NON-OPERATINGReliability Specifications Annualized Return RateStart/Stop Cycles Data ReliabilitySafety Regulatory Compliance Canadian Emissions StatementSignal Cable and Connector IntroductionMechanical Interface Electrical InterfaceCommand Interface General Feature SetSupported Commands Command Feature Register Code ValuesFlush Cache SET Multiple Mode Write Sectors 30hContent Description Word10-19 Serial number 20 Ascii characters 20-21 Retired Content Description Minimum PIO transfer cycle time without flow control Minor version number See Address Offset Reserved Area Boot, Incits TR272001 = release interrupt enabled Supported Content Description Reserved 255 Integrity word 15-8 Checksum Signature Service and Support Product Support/Technical Assistance/Customer ServiceBreaking the 137 Gigabyte Storage Barrier HistoryDOS How is the Extension Implemented? Solving the 137 Gigabyte Capacity BarrierWhat Do the Drives Need to Meet the Spec? What Else is Involved? What is the Next Barrier?Appendix a Appendix B Big Numbers Appendix CGlossary Glossary FCI Acronym for flux changes per inch. See also BPI Initialize See low level formatting Millisecond ms One thousandth of a second .001 sec Glossary Quickview 300 80/100/120/160/200/250/300GB Pata G-7 Glossary Index