FieldServer FS-8700-103 Appendix B.5. Adding / Modifying Malfunction Strings, C2H5OH TGM

Page 19

FS-8700-103_ATMI_TGM_Serial Manual

Page 19 of 28

In the example below the gas name specified is ‘C2H5OH’ and it has been assigned an index value of 7. It will be added to the table.

// Add a new gas name

Driver_Table

 

 

TGM_Gas_Name,

TGM_Gas_Index_Value,

Protocol

C2H5OH,

7,

TGM

Appendix B.5. Adding / Modifying Malfunction Strings

When an event is reported, the driver compares the “MAFLUN” events to those in the table provided in Appendix A.2. The table can be modified or extended.

Add a section to the configuration file which is similar to the text found in the examples below.

In the example below the gas name specified is ‘DISK NEARLY FULL’, an entry from the existing list. When the driver finds the lines below, it will update the index value to 20. Ensure the index value is less than 100.

// Change index value of existing malfunction.

Driver_Table

 

 

TGM_Malfunction_Name,

TGM_Malfunction_Index,

Protocol

DISK NEARLY FULL,

20,

TGM

In the example below the gas name specified is ‘DISK IS FULL’ and it has been assigned an index value of 20. It will be added to the table.

// Add a new malfunction

Driver_Table

 

 

TGM_Malfunction_Name,

TGM_Malfunction_Index,

Protocol

DISK IS FULL,

20,

TGM

FieldServer Technologies 1991 Tarob Court Milpitas, California 95035 USA Web:www.fieldserver.com Tel: (408) 262-2299 Fax: (408) 262-9042 Toll_Free: 888-509-1970 email: support@fieldserver.com

Image 19
Contents FS-8700-103 ATMI-TGM Serial Driver Table of Contents Client Only 1 Server Node Allowed PER Port Max Nodes Supported FieldServer Mode CommentsAtmi TGM Serial Driver Description FS-8700-103ATMITGMSerial ManualFieldServer Technologies Description Required 3rd Party ConfigurationHardware Connections Malfun Printer OFF Line Hardware Connection Tips / HintsMalfun Remote OFF Line Column Title Function Legal Values Configuring the FieldServer as a Atmi TGM Serial ClientData Arrays/Descriptors Section TitleClient Side Node Descriptors Client Side Connection DescriptionsNone Column Function Legal Values Title Driver Related Map Descriptor ParametersTiming Parameters RDBC, ARSCalr Map Descriptor Example #1 Calr ReportMap Descriptor Example #2 QLA Report QIR Map Descriptor Example #3 QIR Report MalfunctionsGEH4 H2AC H2S H2SE HCL N2O NF3 NH3 PH3 Pocl POCL3 Sihx Gas Name Index ValueNone ASH3 CH4 CH4AC CL2 DETOffset Malfunction Return to Normal Appendix A.2. Malfunction TableEngineering Units Index Value Appendix A.3. Gas Concentration Engineering UnitsARU PPM PPB LEL PCT Alarm Reset ALL Malfunctions Clear Data Array specified by the DABitName ContentsAppendix B.2. How Gas Data is Stored Data Array specified by the DataArrayNamePPM TGM Appendix B.4. Adding / Modifying Hard Coded Gas NamesDisk is Full TGM Appendix B.5. Adding / Modifying Malfunction StringsC2H5OH TGM Disk Nearly Full TGMDisk no Longer Full TGM Appendix B.6. Adding / Modifying ‘Return to Normal’ StringsDisk not Full TGM Appendix B.8. Synchronizing Malfunctions FS-8700-103ATMITGMSerial ManualPage 22 Appendix C. Driver Error MessagesMessage FYI FS-8700-103ATMITGMSerial Manual Message#21 UINT16 Appendix C.1. Exposing Driver Operating StatisticsStat Relative Offset FS-8700-103ATMITGMSerial Manual Word baudRate = This page Intentionally Left Blank

FS-8700-103 specifications

The FieldServer FS-8700-103 is an advanced gateway solution designed to facilitate seamless communication between different building automation systems and devices. Its primary function is to provide interoperability among various protocols and devices, which is increasingly important in modern facility management. The FS-8700-103 alleviates common challenges faced by system integrators, allowing for easy integration and operation of diverse systems from multiple manufacturers.

One of the standout features of the FieldServer FS-8700-103 is its support for multiple communication protocols. These include Modbus, BACnet, LonWorks, and SNMP, among others. This versatility allows the FS-8700-103 to serve as a bridge between legacy systems and newer technologies, thus extending the useful life of existing infrastructure while enabling the addition of advanced system capabilities.

The FS-8700-103 is equipped with numerous ports, including Ethernet connections, which support both wired and wireless communications. This flexibility ensures that the gateway can fit into various network configurations and adapt to different deployment scenarios. In addition, its robust design guarantees reliable performance even in demanding environments, making it suitable for use in commercial, industrial, and residential applications.

Another key characteristic of the FS-8700-103 is its intuitive web-based interface. This interface simplifies the configuration process, allowing users to set up the system with minimal technical expertise. The built-in diagnostic tools provide real-time monitoring and troubleshooting capabilities, enabling operators to quickly identify and address issues, thus reducing downtime and enhancing operational efficiency.

Security is also a notable feature of the FS-8700-103. With increasing concerns regarding cybersecurity in building management systems, this gateway incorporates advanced security protocols to protect data integrity and privacy. This ensures that sensitive information remains safeguarded against unauthorized access.

In summary, the FieldServer FS-8700-103 stands out as a reliable and versatile solution for achieving interoperability in building automation systems. Its support for multiple protocols, robust connectivity options, user-friendly interface, and strong security measures make it a valuable asset for any organization looking to streamline operations and enhance the effectiveness of their automation systems. With the FS-8700-103, organizations can move towards a more integrated and efficient future in facility management.