FieldServer FS-8700-103 Required 3rd Party Configuration, FieldServer Technologies Description

Page 4

FS-8700-103_ATMI_TGM_Serial Manual

Page 4 of 28

2.Driver Scope of Supply

2.1.Supplied by FieldServer Technologies for this driver

 

FieldServer Technologies

 

 

Description

 

 

PART #

 

 

 

 

 

 

 

 

 

FS-8917-12

 

Connector, 9-pin female: connects to DTE, DSR/DTR

 

 

loop

 

 

 

 

 

FS-8700-103

Driver Manual.

2.2.Provided by the Supplier of 3rd Party Equipment

2.2.1.Required 3rd Party Hardware

Part #

Description

No specific Hardware requirements other than TGM unit.

2.2.2.Required 3rd Party Configuration

The FieldServer’s serial port must be configured to be used as a ‘Console Port’ on the TGM device. The ‘Console Port’ is configurable. At least one of the two serial ports on the TGM device must be configured to enable the ‘Console Port’. This is not always the case when the TGM is shipped. Notes in Appendix D provide additional information.

FieldServer Technologies 1991 Tarob Court Milpitas, California 95035 USA Web:www.fieldserver.com Tel: (408) 262-2299 Fax: (408) 262-9042 Toll_Free: 888-509-1970 email: support@fieldserver.com

Image 4
Contents FS-8700-103 ATMI-TGM Serial Driver Table of Contents Max Nodes Supported FieldServer Mode Comments Atmi TGM Serial Driver DescriptionFS-8700-103ATMITGMSerial Manual Client Only 1 Server Node Allowed PER PortRequired 3rd Party Configuration FieldServer Technologies DescriptionHardware Connections Malfun Printer OFF Line Hardware Connection Tips / HintsMalfun Remote OFF Line Configuring the FieldServer as a Atmi TGM Serial Client Data Arrays/DescriptorsSection Title Column Title Function Legal ValuesClient Side Node Descriptors Client Side Connection DescriptionsNone Driver Related Map Descriptor Parameters Timing ParametersRDBC, ARS Column Function Legal Values TitleMap Descriptor Example #1 Calr Report CalrMap Descriptor Example #2 QLA Report Map Descriptor Example #3 QIR Report Malfunctions QIRGas Name Index Value None ASH3CH4 CH4AC CL2 DET GEH4 H2AC H2S H2SE HCL N2O NF3 NH3 PH3 Pocl POCL3 SihxAppendix A.2. Malfunction Table Offset Malfunction Return to NormalEngineering Units Index Value Appendix A.3. Gas Concentration Engineering UnitsARU PPM PPB LEL PCT Alarm Reset ALL Malfunctions Clear Contents Appendix B.2. How Gas Data is StoredData Array specified by the DataArrayName Data Array specified by the DABitNameAppendix B.4. Adding / Modifying Hard Coded Gas Names PPM TGMAppendix B.5. Adding / Modifying Malfunction Strings C2H5OH TGMDisk Nearly Full TGM Disk is Full TGMDisk no Longer Full TGM Appendix B.6. Adding / Modifying ‘Return to Normal’ StringsDisk not Full TGM Appendix B.8. Synchronizing Malfunctions FS-8700-103ATMITGMSerial ManualPage 22 Appendix C. Driver Error MessagesMessage FS-8700-103ATMITGMSerial Manual Message FYI#21 UINT16 Appendix C.1. Exposing Driver Operating StatisticsStat Relative Offset FS-8700-103ATMITGMSerial Manual Word baudRate = This page Intentionally Left Blank

FS-8700-103 specifications

The FieldServer FS-8700-103 is an advanced gateway solution designed to facilitate seamless communication between different building automation systems and devices. Its primary function is to provide interoperability among various protocols and devices, which is increasingly important in modern facility management. The FS-8700-103 alleviates common challenges faced by system integrators, allowing for easy integration and operation of diverse systems from multiple manufacturers.

One of the standout features of the FieldServer FS-8700-103 is its support for multiple communication protocols. These include Modbus, BACnet, LonWorks, and SNMP, among others. This versatility allows the FS-8700-103 to serve as a bridge between legacy systems and newer technologies, thus extending the useful life of existing infrastructure while enabling the addition of advanced system capabilities.

The FS-8700-103 is equipped with numerous ports, including Ethernet connections, which support both wired and wireless communications. This flexibility ensures that the gateway can fit into various network configurations and adapt to different deployment scenarios. In addition, its robust design guarantees reliable performance even in demanding environments, making it suitable for use in commercial, industrial, and residential applications.

Another key characteristic of the FS-8700-103 is its intuitive web-based interface. This interface simplifies the configuration process, allowing users to set up the system with minimal technical expertise. The built-in diagnostic tools provide real-time monitoring and troubleshooting capabilities, enabling operators to quickly identify and address issues, thus reducing downtime and enhancing operational efficiency.

Security is also a notable feature of the FS-8700-103. With increasing concerns regarding cybersecurity in building management systems, this gateway incorporates advanced security protocols to protect data integrity and privacy. This ensures that sensitive information remains safeguarded against unauthorized access.

In summary, the FieldServer FS-8700-103 stands out as a reliable and versatile solution for achieving interoperability in building automation systems. Its support for multiple protocols, robust connectivity options, user-friendly interface, and strong security measures make it a valuable asset for any organization looking to streamline operations and enhance the effectiveness of their automation systems. With the FS-8700-103, organizations can move towards a more integrated and efficient future in facility management.